Semiactive robotic-arm system versus patient-specific instrumentation in primary total knee arthroplasty: Efficacy and accuracy

被引:3
作者
He, Rui [1 ]
Sun, Maolin [1 ]
Xiong, Ran [1 ]
Yang, Junjun [1 ]
Guo, Lin [1 ]
Yang, Liu [1 ]
机构
[1] Third Mil Med Univ, Army Med Univ, Southwest Hosp, Ctr Joint Surg, Chongqing 400038, Peoples R China
基金
国家重点研发计划;
关键词
Robotic-arm; Patient-specific instrumentation; Total knee arthroplasty; Rotation alignment; Accuracy; ROTATIONAL ALIGNMENT; FEMORAL COMPONENT; JOINT LINE; STABILITY;
D O I
10.1016/j.asjsur.2022.06.151
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the difference in efficacy and accuracy during total knee arthroplasty (TKA) among robotic-arm system, patient-specific instrumentation (PSI) and conventional TKA (COTKA). Methods: Retrospective analysis of 90 advanced knee osteoarthritis (OA) patients in our hospital be-tween June 2019 and December 2020 was conducted. Patients were divided into robotic arm-assisted (RA)TKA (group A), PSITKA (group B) and COTKA (group C), 30 cases in each group. The operation time, intraoperative bleeding, and length of hospital stay were counted. Imaging data of hip-knee-ankle angle (HKA), posterior condylar angle (PCA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and sagittal tibial component angle (sTCA) were statistically analyzed. The postoperative recovery of the patients was evaluated by Knee Society Score (KSS) and the Western Ontario Mac Master University Index Score (WOMAC). Results: Group A had the least intraoperative bleeding. For operation time, group A was the longest compared with group B and group C (P < 0.05), while group B was longer than group C (P < 0.05). There was no significant difference in HKA, LDFA, and MPTA among the three groups, and the lower limb alignments were all restored to the neutral position. PCA of group A and B were both smaller than that of group C and closer to 0 degrees (P < 0.05), but the difference between group A and B was not statistically significant. The sTCA in group A was significantly better than group B, and group B was significantly better than group C (P < 0.05). There were no significant differences in function scores among the three groups. Conclusion: Compared to the PSI and CO, RA is more minimally invasive and more accurate in radio-graphic results.(c) 2023 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:742 / 750
页数:9
相关论文
共 33 条
[21]  
MARTIN JW, 1990, CLIN ORTHOP RELAT R, P146
[22]   Effect of the presence of the articular cartilage on the femoral component rotation in total knee arthroplasty in female and varus osteoarthritis knees [J].
Nam, Ji-Hoon ;
Koh, Yong-Gon ;
Kim, Paul Shinil ;
Park, Joon-Hee ;
Kang, Kyoung-Tak .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
[23]   Flexion Space Balancing Through Component Positioning and Its Relationship to Traditional Anatomic Rotational Landmarks in Robotic Total Knee Arthroplasty [J].
Nodzo, Scott R. ;
Staub, Trevor M. ;
Jancuska, Jeffrey M. ;
Cobler-Lichter, Michael D. ;
Boyle, K. Keely ;
Rachala, Sridhar .
JOURNAL OF ARTHROPLASTY, 2020, 35 (06) :1569-1575
[24]   Transitioning a Practice to Robotic Total Knee Arthroplasty Is Correlated with Favorable Short-Term Clinical Outcomes-A Single Surgeon Experience [J].
Pannu, Tejbir S. ;
Limtong, Justin ;
Villa, Jesus M. ;
Patel, Preetesh D. ;
Higuera, Carlos A. .
JOURNAL OF KNEE SURGERY, 2023, 36 (04) :456-457
[25]  
Radermacher K, 2012, BIOMED ENG-BIOMED TE, V57, P207, DOI [10.1515/bmt-2012-0401, 10.1515/bmt-2012-401]
[26]   The Influence of the Posterior Cruciate Ligament and Component Design on Joint Line Position After Primary Total Knee Arthroplasty [J].
Snider, Matthew G. ;
MacDonald, Steven J. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (07) :1093-1098
[27]   The Learning Curve Associated with Robotic Total Knee Arthroplasty [J].
Sodhi, Nipun ;
Khlopas, Anton ;
Piuzzi, Nicolas S. ;
Sultan, Assem A. ;
Marchand, Robert C. ;
Malkani, Arthur L. ;
Mont, Michael A. .
JOURNAL OF KNEE SURGERY, 2018, 31 (01) :17-21
[28]   Accuracy of a Novel 3D-Printed Patient-Specific Intramedullary Guide to Control Femoral Component Rotation in Total Knee Arthroplasty [J].
Sun, Mao-lin ;
Zhang, Ying ;
Peng, Yang ;
Fu, De-jie ;
Fan, Hua-quan ;
He, Rui .
ORTHOPAEDIC SURGERY, 2020, 12 (02) :429-441
[29]   Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide [J].
Sun, Maolin ;
Zhang, Ying ;
Peng, Yang ;
Fu, Dejie ;
Fan, Huaquan ;
He, Rui .
BIOMED RESEARCH INTERNATIONAL, 2020, 2020
[30]   Patient Variation Limits Use of Fixed References for Femoral Rotation Component Alignment in Total Knee Arthroplasty [J].
Twiggs, Joshua G. ;
Dickison, David M. ;
Kolos, Elizabeth C. ;
Wilcox, Caitlin E. ;
Roe, Justin P. ;
Fritsch, Brett A. ;
McMahon, Stephen J. ;
Miles, Brad P. ;
Ruys, Andrew J. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (01) :67-74