Semiactive robotic-arm system versus patient-specific instrumentation in primary total knee arthroplasty: Efficacy and accuracy

被引:3
作者
He, Rui [1 ]
Sun, Maolin [1 ]
Xiong, Ran [1 ]
Yang, Junjun [1 ]
Guo, Lin [1 ]
Yang, Liu [1 ]
机构
[1] Third Mil Med Univ, Army Med Univ, Southwest Hosp, Ctr Joint Surg, Chongqing 400038, Peoples R China
基金
国家重点研发计划;
关键词
Robotic-arm; Patient-specific instrumentation; Total knee arthroplasty; Rotation alignment; Accuracy; ROTATIONAL ALIGNMENT; FEMORAL COMPONENT; JOINT LINE; STABILITY;
D O I
10.1016/j.asjsur.2022.06.151
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the difference in efficacy and accuracy during total knee arthroplasty (TKA) among robotic-arm system, patient-specific instrumentation (PSI) and conventional TKA (COTKA). Methods: Retrospective analysis of 90 advanced knee osteoarthritis (OA) patients in our hospital be-tween June 2019 and December 2020 was conducted. Patients were divided into robotic arm-assisted (RA)TKA (group A), PSITKA (group B) and COTKA (group C), 30 cases in each group. The operation time, intraoperative bleeding, and length of hospital stay were counted. Imaging data of hip-knee-ankle angle (HKA), posterior condylar angle (PCA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and sagittal tibial component angle (sTCA) were statistically analyzed. The postoperative recovery of the patients was evaluated by Knee Society Score (KSS) and the Western Ontario Mac Master University Index Score (WOMAC). Results: Group A had the least intraoperative bleeding. For operation time, group A was the longest compared with group B and group C (P < 0.05), while group B was longer than group C (P < 0.05). There was no significant difference in HKA, LDFA, and MPTA among the three groups, and the lower limb alignments were all restored to the neutral position. PCA of group A and B were both smaller than that of group C and closer to 0 degrees (P < 0.05), but the difference between group A and B was not statistically significant. The sTCA in group A was significantly better than group B, and group B was significantly better than group C (P < 0.05). There were no significant differences in function scores among the three groups. Conclusion: Compared to the PSI and CO, RA is more minimally invasive and more accurate in radio-graphic results.(c) 2023 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:742 / 750
页数:9
相关论文
共 33 条
[11]   Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis [J].
Kievit, A. J. ;
Dobbe, J. G. G. ;
Streekstra, G. J. ;
Blankevoort, L. ;
Schafroth, M. U. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) :1751-1758
[12]   The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis [J].
Kim, Young-Hoo ;
Park, Jang-Won ;
Kim, Jun-Shik ;
Park, Sang-Doo .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) :379-385
[13]   Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis [J].
Kizaki, Kazuha ;
Shanmugaraj, Ajaykumar ;
Yamashita, Fumiharu ;
Simunovic, Nicole ;
Duong, Andrew ;
Khanna, Vickas ;
Ayeni, Olufemi R. .
BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
[14]   Obesity and osteoarthritis [J].
Kulkarni, Kunal ;
Karssiens, Timothy ;
Kumar, Vijay ;
Pandit, Hemant .
MATURITAS, 2016, 89 :22-28
[15]   Patient-specific instrumentation in total knee arthroplasty [J].
Leon-Munoz, Vicente J. ;
Martinez-Martinez, Francisco ;
Lopez-Lopez, Mirian ;
Santonja-Medina, Fernando .
EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (07) :555-567
[16]  
Lespasio Michelle J, 2017, Perm J, V21, P16, DOI 10.7812/TPP/16-183
[17]   Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial [J].
Liow, Ming Han Lincoln ;
Goh, Graham Seow-Hng ;
Wong, Merng Koon ;
Chin, Pak Lin ;
Tay, Darren Keng-Jin ;
Yeo, Seng-Jin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) :2942-2951
[18]   Robot-Assisted Total Knee Arthroplasty Accurately Restores the Joint Line and Mechanical Axis. A Prospective Randomised Study [J].
Liow, Ming Han Lincoln ;
Xia, Zhan ;
Wong, Merng Koon ;
Tay, Keng Jin ;
Yeo, Seng Jin ;
Chin, Pak Lin .
JOURNAL OF ARTHROPLASTY, 2014, 29 (12) :2373-2377
[19]   An Innovative Three-Dimensional Method for Identifying a Proper Femoral Intramedullary Entry Point in Total Knee Arthroplasty [J].
Ma, Lu-Yao ;
Wei, Hong-Yu ;
Wan, Fu-Yin ;
Guo, Wan-Shou ;
Ma, Jin-Hui .
CHINESE MEDICAL JOURNAL, 2018, 131 (21) :2531-2536
[20]   Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty [J].
Maderbacher, Guenther ;
Matussek, Jan ;
Keshmiri, Armin ;
Greimel, Felix ;
Baier, Clemens ;
Grifka, Joachim ;
Maderbacher, Hermann .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) :3311-3316