Semiactive robotic-arm system versus patient-specific instrumentation in primary total knee arthroplasty: Efficacy and accuracy

被引:3
作者
He, Rui [1 ]
Sun, Maolin [1 ]
Xiong, Ran [1 ]
Yang, Junjun [1 ]
Guo, Lin [1 ]
Yang, Liu [1 ]
机构
[1] Third Mil Med Univ, Army Med Univ, Southwest Hosp, Ctr Joint Surg, Chongqing 400038, Peoples R China
基金
国家重点研发计划;
关键词
Robotic-arm; Patient-specific instrumentation; Total knee arthroplasty; Rotation alignment; Accuracy; ROTATIONAL ALIGNMENT; FEMORAL COMPONENT; JOINT LINE; STABILITY;
D O I
10.1016/j.asjsur.2022.06.151
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the difference in efficacy and accuracy during total knee arthroplasty (TKA) among robotic-arm system, patient-specific instrumentation (PSI) and conventional TKA (COTKA). Methods: Retrospective analysis of 90 advanced knee osteoarthritis (OA) patients in our hospital be-tween June 2019 and December 2020 was conducted. Patients were divided into robotic arm-assisted (RA)TKA (group A), PSITKA (group B) and COTKA (group C), 30 cases in each group. The operation time, intraoperative bleeding, and length of hospital stay were counted. Imaging data of hip-knee-ankle angle (HKA), posterior condylar angle (PCA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and sagittal tibial component angle (sTCA) were statistically analyzed. The postoperative recovery of the patients was evaluated by Knee Society Score (KSS) and the Western Ontario Mac Master University Index Score (WOMAC). Results: Group A had the least intraoperative bleeding. For operation time, group A was the longest compared with group B and group C (P < 0.05), while group B was longer than group C (P < 0.05). There was no significant difference in HKA, LDFA, and MPTA among the three groups, and the lower limb alignments were all restored to the neutral position. PCA of group A and B were both smaller than that of group C and closer to 0 degrees (P < 0.05), but the difference between group A and B was not statistically significant. The sTCA in group A was significantly better than group B, and group B was significantly better than group C (P < 0.05). There were no significant differences in function scores among the three groups. Conclusion: Compared to the PSI and CO, RA is more minimally invasive and more accurate in radio-graphic results.(c) 2023 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页码:742 / 750
页数:9
相关论文
共 33 条
[1]  
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
[2]  
Antonios Joseph K, 2019, Arthroplast Today, V5, P88, DOI 10.1016/j.artd.2019.01.002
[3]   Robot-assisted total knee arthroplasty [J].
Bellemans, Johan ;
Vandenneucker, Hilde ;
Vanlauwe, Johan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) :111-116
[4]   Quality of life after total knee arthroplasty [J].
Canovas, F. ;
Dagneaux, L. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (01) :S41-S46
[5]  
Cielinski Lukasz, 2016, Ortop Traumatol Rehabil, V18, P549, DOI 10.5604/15093492.1230540
[6]  
Deep K, 2017, SICOT-J, V3, DOI 10.1051/sicotj/2017034
[7]   Femoral Component Rotation in Total Knee Arthroplasty: A Comparison Between Transepicondylar Axis and Posterior Condylar Line Referencing [J].
Franceschini, Vincenzo ;
Nodzo, Scott R. ;
Della Valle, Alejandro Gonzalez .
JOURNAL OF ARTHROPLASTY, 2016, 31 (12) :2917-2921
[8]   Patient Dissatisfaction Following Total Knee Arthroplasty: A Systematic Review of the Literature [J].
Gunaratne, Rajitha ;
Pratt, Dylan N. ;
Banda, Joseph ;
Fick, Daniel P. ;
Khan, Riaz J. K. ;
Robertson, Brett W. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (12) :3854-3860
[9]   Knee osteoarthritis: a review of management options [J].
Hussain, S. M. ;
Neilly, D. W. ;
Baliga, S. ;
Patil, S. ;
Meek, R. M. D. .
SCOTTISH MEDICAL JOURNAL, 2016, 61 (01) :7-16
[10]   Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning [J].
Kayani, Babar ;
Konan, S. ;
Huq, S. S. ;
Tahmassebi, J. ;
Haddad, F. S. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) :1132-1141