Outcome of Precontoured Titanium Mesh in the Reconstruction of Orbital Blowout Fractures

被引:3
作者
Munoli, Amarnath [1 ]
Bhanushali, Jinisha [1 ]
Jagannathan, Mukund [1 ]
机构
[1] Lokmanya Tilak Municipal Med Coll & Gen Hosp, Dept Plast & Reconstruct Surg, Mumbai, India
关键词
blowout fracture; titanium mesh; precontoured titanium mesh; enophthalmos; orbital floor; BIOMATERIALS; REPAIR;
D O I
10.1055/s-0043-1761597
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Orbital blowout fractures are peculiar injuries causing disruption of both ocular function and symmetry. We present our experience with the use of a precontoured titanium mesh in orbital blowout fractures.Methods A retrospective study of patients undergoing correction of orbital blowout fractures with a precontoured titanium mesh was done at a tertiary care center in Mumbai. Data regarding demographics and pre- and postoperative clinical and radiological attributes were retrieved and compared.Results A total of 21 patients (19 males and 2 females) underwent correction of blowout fractures with a precontoured titanium mesh. The follow-up period ranged from 6 to 10 months. Road traffic accident (76%) was the most common etiology. Twenty (95%) patients had impure blowout fractures and 1 (5%) patient had a pure blowout. The orbital floor was most commonly fractured (16 [76%]). Associated fractures of the zygomaticomaxillary complex were found in 71% of patients. All patients were operated on within 3 weeks of trauma. A comparison of the operated and uninjured sides on coronal views of computed tomography (CT) scan in nine patients by Photopea application revealed a correction of the increased cross-sectional area in all cases. Enophthalmos was completely corrected in 94% patients, while 92% patients had complete correction of diplopia. One patient with a comminuted zygomatic fracture had persistent diplopia and mild enophthalmos. Infraorbital paresthesia persisted in 58% patients at 6 months of follow-up. No significant postoperative complications were noted.Conclusion The precontoured titanium mesh restores orbital wall anatomy and is safe, quick, fairly easy, and reproducible with a shorter learning curve. With proper patient selection and execution, prefabricated titanium mesh can serve as an excellent reconstructive option in blowout fractures of the orbit.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 18 条
  • [1] Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh
    Ellis, E
    Tan, YH
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (04) : 442 - 453
  • [2] Biomaterials for Repair of Orbital Floor Blowout Fractures: A Systematic Review
    Gunarajah, Dharmindra Rajah
    Samman, Nabil
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) : 550 - 570
  • [3] Han XH, 2016, INT J CLIN EXP MED, V9, P12411
  • [4] HAWES MJ, 1983, OPHTHALMOLOGY, V90, P1066
  • [5] Jatania H., 2012, DISSERTATION, P30
  • [6] A Case Series of Rapid Prototyping and Intraoperative Imaging in Orbital Reconstruction
    Lim, Christopher G. T.
    Campbell, Duncan I.
    Cook, Nicholas
    Erasmus, Jason
    [J]. CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2015, 8 (02) : 105 - 110
  • [7] MECHANISMS OF GLOBAL SUPPORT AND POSTTRAUMATIC ENOPHTHALMOS .1. THE ANATOMY OF THE LIGAMENT SLING AND ITS RELATION TO INTRAMUSCULAR CONE ORBITAL FAT
    MANSON, PN
    CLIFFORD, CM
    ILIFF, NT
    MORGAN, R
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (02) : 193 - 202
  • [8] Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures
    Metzger, Marc C.
    Schoen, Ralf
    Weyer, Nils
    Rafii, Amir
    Gellrich, Nils-Claudius
    Schmelzeisen, Rainer
    Strong, Bradley E.
    [J]. OPHTHALMOLOGY, 2006, 113 (10) : 1863 - 1868
  • [9] Individual preformed titanium meshes for orbital fractures
    Metzger, Marc Christian
    Schoen, Ralf
    Schulze, Dirk
    Carvalho, Carlos
    Gutwald, Ralf
    Schmelzeisen, Rainer
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : 442 - 447
  • [10] Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants
    Nam, SB
    Bae, YC
    Moon, JS