Fragility assessment for new and deteriorated portal framed industrial buildings subjected to tropical cyclone winds

被引:8
作者
Qin, Hao [1 ]
Mason, Matthew [2 ]
Stewart, Mark G. [1 ]
机构
[1] Univ Technol Sydney, Sch Civil & Environm Engn, Sydney, Australia
[2] Univ Queensland, Sch Civil Engn, Brisbane, Australia
关键词
Fragility; Low-rise industrial buildings; Steel portal frame; Metal cladding; Building deterioration; Tropical cyclone; RELIABILITY; DAMAGE; LOADS; PRESSURE;
D O I
10.1016/j.strusafe.2022.102287
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Low-rise portal framed industrial buildings are widely used as warehouses, workshops and storage facilities. Damage surveys following severe tropical cyclones have shown that both structural and non-structural damage can occur to these buildings. While non-structural damage to the building envelope of portal framed industrial buildings are considered by several existing fragility models, almost none exist that include structural failures in the wind fragility assessment. This study develops a fragility assessment method for portal framed industrial buildings that accounts for wind-induced damage to both structural (steel portal frame and end wall frame) and non-structural (metal cladding system and fenestration) building components. Fragility curves are developed for a prototype industrial building located on the cyclone-prone east coast of Australia considering four damage states with increasing damage severity. A Monte Carlo simulation incorporating probabilistic models of the spatio-temporal variable wind pressures, wind-induced demands and component capacities is employed to conduct the fragility assessment for both individual building components and the building system under critical failure modes. It was found that the fragility of structural framing is non-negligible when wind speed exceeds 80% of the design level. Structural framing failure is a major contributor to the most severe damage state and is a necessary inclusion in the fragility assessment for this type of building. A sensitivity analysis also showed that fastener corrosion can significantly increase the fragility of deteriorated buildings near to coastlines, particularly for low levels of damage.
引用
收藏
页数:21
相关论文
共 45 条
  • [1] [Anonymous], 2011, ASNZS11702
  • [2] Low-rise gable roof wind loads: Characterization and stochastic simulation
    Cope, AD
    Gurley, KR
    Gioffre, M
    Reinhold, TA
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2005, 93 (09) : 719 - 738
  • [3] Observations of structural damage caused by Hurricane Katrina on the Mississippi Gulf Coast
    Eamon, Christopher D.
    Fitzpatrick, Patrick
    Truax, Dennis D.
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2007, 21 (02) : 117 - 127
  • [4] FEMA, 2021, Hazus Hurricane Model Technical Manual: Hazus4.2 Service Pack3
  • [5] GALAMBOS TV, 1981, ENG J AISC, V18, P74
  • [6] Storm duration effects on roof-to-wall-connection failures of a residential, wood-frame, gable roof
    Guha, T. K.
    Kopp, Gregory A.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2014, 133 : 101 - 109
  • [7] Henderson DJ, 2006, technical report 51
  • [8] The UWO contribution to the NIST aerodynamic database for wind loads on low buildings: Part 1. Archiving format and basic aerodynamic data
    Ho, TCE
    Surry, D
    Morrish, D
    Kopp, GA
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2005, 93 (01) : 1 - 30
  • [9] Hogan TJ, 1997, AISC STEEL CONSTRUCT, V31, P2
  • [10] Holmes J. D., 1985, CIVIL ENG T I ENG AU, VCE27, P21