Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment

被引:3
作者
Patamarat, Apisit [1 ]
Laoruengthana, Artit [2 ,6 ]
Kitcharanant, Nitchanant [3 ]
Khantasit, Jakkaphong [4 ]
Thremthakanpon, Witoon [5 ]
机构
[1] Phra Nakhon Si Ayutthaya Hosp, Dept Orthopaed Surg, Ayutthaya, Thailand
[2] Naresuan Univ, Fac Med, Dept Orthopaed, Phitsanulok, Thailand
[3] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[4] Phra Nakhon Si Ayutthaya Hosp, Dept Nursing, Ayutthaya, Thailand
[5] Phitsanulok Hosp, Dept Orthopaed, Phitsanulok, Thailand
[6] Naresuan Univ, Fac Med, Dept Orthopaed, 99 Moo Thapho, Phitsanulok 65000, Thailand
来源
ARTHROPLASTY TODAY | 2023年 / 21卷
关键词
Anatomical registration; Computer-assisted; Acetabular cup alignment; Total hip arthroplasty; ANTERIOR PELVIC PLANE; POLYETHYLENE WEAR; NAVIGATION; REPLACEMENT; ORIENTATION; POSITION; TILT;
D O I
10.1016/j.artd.2023.101148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Computer-assisted total hip arthroplasty using direct anatomic registration (DAR) with acetabular center axis software is an alternative method to the indirect anterior pelvic plane method. The software maps the center of hip rotation and orientation of the native acetabulum in 3 dimensions. This study aimed to evaluate the accuracy of acetabular cup alignment using DAR navigation combined with a mechanical guide device (MGD).Methods: This prospective nonrandomized controlled study included 106 patients who underwent primary cementless total hip arthroplasty through the posterolateral approach. Fifty-four patients in the study group underwent DAR combined with MGD, whereas 52 patients underwent MGD only for acetabular cup positioning. Plain radiographs of both hips and computerized tomographic scans were obtained 2 months postoperatively for the evaluation of acetabular cup inclination and anteversion, respectively.Results: The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05). The study group had a mean inclination angle of 43.88(degrees degrees) (standard deviation [SD] 5.38) and anteversion angle of 12.82(degrees)(SD 5.99), whereas the control group had 41.10(degrees)(SD 6.79) and 12.82(degrees) (SD 9.53), respectively. There were no significant differences in estimated blood loss, length of stay, and Harris hip scores at preoperative and 3 and 6 months postoperatively, except for the operative time, which was longer in the study group (P < .01). There was 1 posterior hip dislocation in each group.Conclusions: DAR navigation combined with MGD provides better accuracy for acetabular cup positioning within the Lewinnek safe zone compared with the conventional technique.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Computer-assisted surgery in total hip arthroplasty A review of the literature and current concepts
    Beckmann, J.
    Springorum, H. R.
    Lechler, P.
    Luering, C.
    Tingart, M.
    Grifka, J.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2010, 61 (04) : 285 - 292
  • [42] Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study
    Gupta, Asheesh
    Redmond, John M.
    Hammarstedt, Jon E.
    Petrakos, Alexandra E.
    Vemula, S. Pavan
    Domb, Benjamin G.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2204 - 2207
  • [43] Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery
    Renkawitz, Tobias
    Tingart, Markus
    Grifka, Joachim
    Sendtner, Ernst
    Kalteis, Thomas
    EXPERT REVIEW OF MEDICAL DEVICES, 2009, 6 (05) : 507 - 514
  • [44] Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position
    Sendtner, Ernst
    Schuster, Tibor
    Woerner, Michael
    Kalteis, Thomas
    Grifka, Joachim
    Renkawitz, Tobias
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (06) : 809 - 815
  • [45] Computer-Assisted Navigation Software Advancements Improve the Accuracy of Total Knee Arthroplasty
    Molli, Ryan G.
    Anderson, Kevin C.
    Buehler, Knute C.
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03) : 432 - 438
  • [46] Trends in cup position utilizing computer-assisted navigation during total hip arthroplasty: A retrospective observational study
    Mays, Rachel R.
    Benson, Jessica R.
    Muir, Jeffrey M.
    Meftah, Morteza
    CURRENT ORTHOPAEDIC PRACTICE, 2020, 31 (03): : 211 - 217
  • [47] Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?
    Krueger, S.
    Zambelli, P. Y.
    Leyvraz, P. -F.
    Jolles, B. M.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 27 - 33
  • [48] Computer-assisted navigated cup placement of different cup types in hip arthroplasty - A randomised controlled trial
    Bernsmann, K
    Langlotz, U
    Ansari, B
    Wiese, M
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (06): : 512 - 516
  • [49] The benefits of computer-assisted total knee arthroplasty on coronal alignment with marked femoral bowing in Asian patients
    Lee, Chien-Yin
    Lin, Shih-Jie
    Kuo, Liang-Tseng
    Peng, Kuo-Ti
    Huang, Kuo-Chin
    Huang, Tsan-Wen
    Lee, Mel S.
    Hsu, Robert Wen-Wei
    Shen, Wun-Jer
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9 : 122
  • [50] Accuracy and reproducibility of visual estimation of the acetabular cup positioning in total hip arthroplasty on plain radiographs by orthopaedic surgeons
    Somerville, Charlotte M. B.
    Geddes, James Arthur
    Tofighi, Mehdi
    Boddu, Krishna
    JOURNAL OF PERIOPERATIVE PRACTICE, 2022, 32 (10) : 265 - 269