Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment

被引:3
作者
Patamarat, Apisit [1 ]
Laoruengthana, Artit [2 ,6 ]
Kitcharanant, Nitchanant [3 ]
Khantasit, Jakkaphong [4 ]
Thremthakanpon, Witoon [5 ]
机构
[1] Phra Nakhon Si Ayutthaya Hosp, Dept Orthopaed Surg, Ayutthaya, Thailand
[2] Naresuan Univ, Fac Med, Dept Orthopaed, Phitsanulok, Thailand
[3] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[4] Phra Nakhon Si Ayutthaya Hosp, Dept Nursing, Ayutthaya, Thailand
[5] Phitsanulok Hosp, Dept Orthopaed, Phitsanulok, Thailand
[6] Naresuan Univ, Fac Med, Dept Orthopaed, 99 Moo Thapho, Phitsanulok 65000, Thailand
来源
ARTHROPLASTY TODAY | 2023年 / 21卷
关键词
Anatomical registration; Computer-assisted; Acetabular cup alignment; Total hip arthroplasty; ANTERIOR PELVIC PLANE; POLYETHYLENE WEAR; NAVIGATION; REPLACEMENT; ORIENTATION; POSITION; TILT;
D O I
10.1016/j.artd.2023.101148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Computer-assisted total hip arthroplasty using direct anatomic registration (DAR) with acetabular center axis software is an alternative method to the indirect anterior pelvic plane method. The software maps the center of hip rotation and orientation of the native acetabulum in 3 dimensions. This study aimed to evaluate the accuracy of acetabular cup alignment using DAR navigation combined with a mechanical guide device (MGD).Methods: This prospective nonrandomized controlled study included 106 patients who underwent primary cementless total hip arthroplasty through the posterolateral approach. Fifty-four patients in the study group underwent DAR combined with MGD, whereas 52 patients underwent MGD only for acetabular cup positioning. Plain radiographs of both hips and computerized tomographic scans were obtained 2 months postoperatively for the evaluation of acetabular cup inclination and anteversion, respectively.Results: The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05). The study group had a mean inclination angle of 43.88(degrees degrees) (standard deviation [SD] 5.38) and anteversion angle of 12.82(degrees)(SD 5.99), whereas the control group had 41.10(degrees)(SD 6.79) and 12.82(degrees) (SD 9.53), respectively. There were no significant differences in estimated blood loss, length of stay, and Harris hip scores at preoperative and 3 and 6 months postoperatively, except for the operative time, which was longer in the study group (P < .01). There was 1 posterior hip dislocation in each group.Conclusions: DAR navigation combined with MGD provides better accuracy for acetabular cup positioning within the Lewinnek safe zone compared with the conventional technique.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Comparison of Postoperative Instability and Acetabular Cup Positioning in Robotic-Assisted Versus Traditional Total Hip Arthroplasty
    Shaw, Jonathan H.
    Rahman, Tahsin M.
    Wesemann, Luke D.
    Jiang, Charles Z.
    Lindsay-Rivera, Kevin G.
    Davis, Jason J.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (08) : S881 - S889
  • [32] Three-Dimensional Templating for Acetabular Component Alignment During Total Hip Arthroplasty
    Elbuluk, Ameer M.
    Wojack, Paul
    Eftekhary, Nima
    Vigdorchik, Jonanathan M.
    ORTHOPEDICS, 2017, 40 (04) : E708 - E713
  • [33] Modern cup alignment techniques in total hip arthroplasty: A systematic review
    Maillot, Cedric
    Harman, Ciara
    Villet, Loic
    Cobb, Justin
    Riviere, Charles
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (05) : 907 - 913
  • [34] Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review
    Snijders, Thom E.
    Willemsen, Koen
    van Gaalen, Steven M.
    Castelein, Rene M.
    Weinans, Harrie
    de Gast, Arthur
    HIP INTERNATIONAL, 2019, 29 (01) : 41 - 50
  • [35] Accurate Acetabular Component Orientation After Total Hip Arthroplasty Using an Acetabular Alignment Guide
    Kanoh, Toshiya
    Hasegawa, Yukiharu
    Masui, Tetsuo
    Yamaguchi, Jin
    Kawabe, Kiyoharu
    Ishiguro, Naoki
    JOURNAL OF ARTHROPLASTY, 2010, 25 (01) : 81 - 86
  • [36] Computer-assisted positioning of the acetabular cup for total hip arthroplasty based on joint kinematics without prior imaging: preliminary results with computed tomographic assessment
    Laffargue, P.
    Pinoit, Y.
    Tabutin, J.
    Giraud, F.
    Puget, J.
    Migaud, H.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (04): : 316 - 325
  • [37] Accuracy and Precision of Two Computer-Assisted Methods of Radiographic Wear Measurement in Total Hip Arthroplasty
    Crockarell, John R., Jr.
    Snearly, Christine M.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (01) : 37 - 40
  • [38] Navigating the Reaming of the Acetabular Cavity in Total Hip Arthroplasty: Does it Improve Implantation Accuracy?
    Pagkalos, Joseph
    Chaudary, Muhammad Imran
    Davis, Edward T.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1749 - 1752
  • [39] Research Synthesis of Recommended Acetabular Cup Orientations for Total Hip Arthroplasty
    Harrison, Claire L.
    Thomson, Avril I.
    Cutts, Steven
    Rowe, Philip J.
    Riches, Philip E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02) : 377 - 382
  • [40] Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip
    Zhang, Yuan Z.
    Chen, Bin
    Lu, Sheng
    Yang, Yong
    Zhao, Jian M.
    Liu, Rui
    Li, Yan B.
    Pei, Guo X.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (04) : 469 - 474