Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment

被引:3
|
作者
Patamarat, Apisit [1 ]
Laoruengthana, Artit [2 ,6 ]
Kitcharanant, Nitchanant [3 ]
Khantasit, Jakkaphong [4 ]
Thremthakanpon, Witoon [5 ]
机构
[1] Phra Nakhon Si Ayutthaya Hosp, Dept Orthopaed Surg, Ayutthaya, Thailand
[2] Naresuan Univ, Fac Med, Dept Orthopaed, Phitsanulok, Thailand
[3] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[4] Phra Nakhon Si Ayutthaya Hosp, Dept Nursing, Ayutthaya, Thailand
[5] Phitsanulok Hosp, Dept Orthopaed, Phitsanulok, Thailand
[6] Naresuan Univ, Fac Med, Dept Orthopaed, 99 Moo Thapho, Phitsanulok 65000, Thailand
来源
ARTHROPLASTY TODAY | 2023年 / 21卷
关键词
Anatomical registration; Computer-assisted; Acetabular cup alignment; Total hip arthroplasty; ANTERIOR PELVIC PLANE; POLYETHYLENE WEAR; NAVIGATION; REPLACEMENT; ORIENTATION; POSITION; TILT;
D O I
10.1016/j.artd.2023.101148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Computer-assisted total hip arthroplasty using direct anatomic registration (DAR) with acetabular center axis software is an alternative method to the indirect anterior pelvic plane method. The software maps the center of hip rotation and orientation of the native acetabulum in 3 dimensions. This study aimed to evaluate the accuracy of acetabular cup alignment using DAR navigation combined with a mechanical guide device (MGD).Methods: This prospective nonrandomized controlled study included 106 patients who underwent primary cementless total hip arthroplasty through the posterolateral approach. Fifty-four patients in the study group underwent DAR combined with MGD, whereas 52 patients underwent MGD only for acetabular cup positioning. Plain radiographs of both hips and computerized tomographic scans were obtained 2 months postoperatively for the evaluation of acetabular cup inclination and anteversion, respectively.Results: The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05). The study group had a mean inclination angle of 43.88(degrees degrees) (standard deviation [SD] 5.38) and anteversion angle of 12.82(degrees)(SD 5.99), whereas the control group had 41.10(degrees)(SD 6.79) and 12.82(degrees) (SD 9.53), respectively. There were no significant differences in estimated blood loss, length of stay, and Harris hip scores at preoperative and 3 and 6 months postoperatively, except for the operative time, which was longer in the study group (P < .01). There was 1 posterior hip dislocation in each group.Conclusions: DAR navigation combined with MGD provides better accuracy for acetabular cup positioning within the Lewinnek safe zone compared with the conventional technique.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Quantitative computer-assisted osteodensitometry in total hip arthroplasty
    Pitto, R. P.
    Mueller, L. A.
    Reilly, K.
    Schmidt, R.
    Munro, J.
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (04) : 431 - 438
  • [22] Computer-assisted osteodensitometry following total hip arthroplasty
    Reilly, Keryn
    Munro, Jacob
    Pitto, Rocco P.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) : 763 - 768
  • [23] How far above the true anatomic position can the acetabular cup be placed in total hip arthroplasty?
    Fukui, Kiyokazu
    Kaneuji, Ayumi
    Sugimori, Tanzo
    Ichiseki, Toru
    Matsumoto, Tadami
    HIP INTERNATIONAL, 2013, 23 (02) : 129 - 134
  • [24] Computer-assisted revision of total knee arthroplasty
    de Ladoucette, Aymard
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (10) : 1166 - 1171
  • [25] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [26] Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography
    Bayraktar, Vahdettin
    Weber, Markus
    von Kunow, Frederik
    Zeman, Florian
    Craiovan, Benjamin
    Renkawitz, Tobias
    Grifka, Joachim
    Woerner, Michael
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) : 731 - 738
  • [27] Smartphone-assisted technique in total hip arthroplasty can improve the precision of acetabular cup placement: a randomised controlled trial
    Pongkunakorn, Anuwat
    Diewwattanawiwat, Kittipong
    Chatmaitri, Swist
    HIP INTERNATIONAL, 2021, 31 (01) : 50 - 57
  • [28] Evaluating Alternate Registration Planes for Imageless, Computer-Assisted Navigation During Total Hip Arthroplasty
    Vigdorchik, Jonathan M.
    Sculco, Peter K.
    Inglis, Allan E.
    Schwarzkopf, Ran
    Muir, Jeffrey M.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (10) : 3527 - 3533
  • [29] Influence of the optical system and anatomic points on computer-assisted total knee arthroplasty
    Schlatterer, B.
    Linares, J. -M.
    Chabrand, P.
    Sprauel, J. -M.
    Argenson, J. -N.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (04) : 395 - 402