Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment

被引:3
|
作者
Patamarat, Apisit [1 ]
Laoruengthana, Artit [2 ,6 ]
Kitcharanant, Nitchanant [3 ]
Khantasit, Jakkaphong [4 ]
Thremthakanpon, Witoon [5 ]
机构
[1] Phra Nakhon Si Ayutthaya Hosp, Dept Orthopaed Surg, Ayutthaya, Thailand
[2] Naresuan Univ, Fac Med, Dept Orthopaed, Phitsanulok, Thailand
[3] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[4] Phra Nakhon Si Ayutthaya Hosp, Dept Nursing, Ayutthaya, Thailand
[5] Phitsanulok Hosp, Dept Orthopaed, Phitsanulok, Thailand
[6] Naresuan Univ, Fac Med, Dept Orthopaed, 99 Moo Thapho, Phitsanulok 65000, Thailand
来源
ARTHROPLASTY TODAY | 2023年 / 21卷
关键词
Anatomical registration; Computer-assisted; Acetabular cup alignment; Total hip arthroplasty; ANTERIOR PELVIC PLANE; POLYETHYLENE WEAR; NAVIGATION; REPLACEMENT; ORIENTATION; POSITION; TILT;
D O I
10.1016/j.artd.2023.101148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Computer-assisted total hip arthroplasty using direct anatomic registration (DAR) with acetabular center axis software is an alternative method to the indirect anterior pelvic plane method. The software maps the center of hip rotation and orientation of the native acetabulum in 3 dimensions. This study aimed to evaluate the accuracy of acetabular cup alignment using DAR navigation combined with a mechanical guide device (MGD).Methods: This prospective nonrandomized controlled study included 106 patients who underwent primary cementless total hip arthroplasty through the posterolateral approach. Fifty-four patients in the study group underwent DAR combined with MGD, whereas 52 patients underwent MGD only for acetabular cup positioning. Plain radiographs of both hips and computerized tomographic scans were obtained 2 months postoperatively for the evaluation of acetabular cup inclination and anteversion, respectively.Results: The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05). The study group had a mean inclination angle of 43.88(degrees degrees) (standard deviation [SD] 5.38) and anteversion angle of 12.82(degrees)(SD 5.99), whereas the control group had 41.10(degrees)(SD 6.79) and 12.82(degrees) (SD 9.53), respectively. There were no significant differences in estimated blood loss, length of stay, and Harris hip scores at preoperative and 3 and 6 months postoperatively, except for the operative time, which was longer in the study group (P < .01). There was 1 posterior hip dislocation in each group.Conclusions: DAR navigation combined with MGD provides better accuracy for acetabular cup positioning within the Lewinnek safe zone compared with the conventional technique.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Computer-Assisted Total Hip Arthroplasty Improves Acetabular Prosthesis Placement Accuracy: A Multicenter, Randomized Controlled Clinical Study
    Zhou, Ge
    Geng, Xiao
    Zhang, Ming
    Sun, Zhiwen
    Li, Feng
    Zhao, Minwei
    Tian, Hua
    ORTHOPAEDIC SURGERY, 2024, 16 (12) : 3078 - 3087
  • [2] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [3] Evaluation of cup placement accuracy in computer assisted total hip arthroplasty
    Kaneta, Hiroki
    Shoji, Takeshi
    Ueki, Shinichi
    Morita, Hiroyuki
    Kozuma, Yosuke
    Adachi, Nobuo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [4] Alignment of Computer-Assisted Total Knee Arthroplasty in Patients With Altered Hip Center
    Mullaji, Arun B.
    Lingaraju, A. P.
    Shetty, Gautam M.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07) : 1072 - 1077
  • [5] Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation
    Singh, Ashish
    Kumar, Purushotam
    Kalyan, Kanukuntla
    Gundalli, Akash Chandrashekar
    Mane, Sudhir Shankar
    Swarnkar, Himanshu
    Singh, Lavanya
    SICOT-J, 2024, 10
  • [6] Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 238 - 246
  • [7] Reliability and accuracy of intraoperative fluoroscopy assessment of acetabular cup anteversion in supine direct anterior approach total hip arthroplasty
    Li, Weihua
    Huang, Yan
    Zou, Zehui
    Liu, Xuqiang
    Li, Xiaofeng
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Ming Han Lincoln Liow
    Graham Seow-Hng Goh
    Hee-Nee Pang
    Darren Keng Jin Tay
    Ngai Nung Lo
    Seng Jin Yeo
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1173 - 1180
  • [9] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Liow, Ming Han Lincoln
    Goh, Graham Seow-Hng
    Pang, Hee-Nee
    Tay, Darren Keng Jin
    Lo, Ngai Nung
    Yeo, Seng Jin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (08) : 1173 - 1180
  • [10] Accuracy of acetabular cup placement using an angle-adjusting alignment guide with laser pointer in total hip arthroplasty
    Okanoue, Yusuke
    Aso, Koji
    Dan, Junpei
    Takaya, Shogo
    Izumi, Masashi
    Kawakami, Teruhiko
    Ikeuchi, Masahiko
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)