Determination of the dose rate around a HDR 192Ir brachytherapy source with the microDiamond and the microSilicon detector

被引:3
作者
Rossi, Giulio [1 ,2 ,8 ]
Failing, Thomas [3 ,4 ]
Gainey, Mark [1 ,2 ]
Kollefrath, Michael [1 ,2 ]
Hensley, Frank [5 ]
Zink, Klemens [3 ,6 ,7 ]
Baltas, Dimos [1 ,2 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Radiat Oncol, Freiburg, Germany
[2] German Canc Res Ctr, German Canc Consortium DKTK Partner Site Freiburg, Heidelberg, Germany
[3] Univ Appl Sci Giessen, Inst Med Phys & Radiat Protect, Giessen, Germany
[4] Univ Med Ctr Gottingen, Dept Radiat Oncol, Gottingen, Germany
[5] Univ Hosp Heidelberg, Dept Radiat Oncol, Heidelberg, Germany
[6] Univ Med Ctr Giessen Marburg, Dept Radiotherapy & Radiat Oncol, Marburg, Germany
[7] Marburg Ionbeam Therapycenter MIT, Marburg, Germany
[8] Univ Freiburg, Fac Med, German Canc Res Ctr DKFZ,Dept Radiat Oncol,Div Med, Med Ctr,German Canc Consortium DKTK Partner Site F, Heidelberg, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 04期
关键词
microDiamond; microSilicon; 192Ir; brachytherapy; dosimetry; Monte Carlo simulations; MONTE-CARLO-SIMULATION; IR-192; SOURCE; DOSIMETRY; AAPM; ANISOTROPY; TRANSPORT; WATER; TLD;
D O I
10.1016/j.zemedi.2022.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To employ the microDiamond and the microSilicon detector (mDD and mSD, both PTW-Freiburg, Germany) to determine the dose rate around a HDR 192Ir brachytherapy source (model mHDR-v2r, Elekta AB, Sweden).Methods: The detectors were calibrated with a 60Co beam at the PTW Calibration Laboratory. Measurements around the 192Ir source were performed inside a PTW MP3 water phantom. The detectors were placed at selected points of measure-ment at radial distances r, ranging from 0.5 to 10 cm, keeping the polar angle 0 = 90 degrees. Additional measurements were performed with the mSD at fixed distances r = 1, 3 and 5 cm, with 0 varying from 0 to 150 degrees, 0 to 166 degrees, and 0 to 168 degrees, respectively. The corresponding mDD readings were already available from a previous work (Rossi et al., 2020). The beam quality correction factor of both detectors, as well as a phantom effect correction factor to account for the differ-ence between the experimental geometry and that assumed in the TG-43 formalism, were determined using the Monte Carlo (MC) toolkit EGSnrc. The beam quality correction factor was factorized into energy dependence and volume -averaging correction factors. Using the abovementioned MC-based factors, the dose rate to water at the different points of measurement in TG-43 conditions was obtained from the measured readings, and was compared to the dose rate cal-culated according to the TG-43 formalism.Results: The beam quality correction factor was considerably closer to unity for the mDD than for the mSD. The energy dependence of the mDD showed a very weak radial dependence, similar to the previous findings showing a weak angular dependence as well (Rossi et al., 2020). Conversely, the energy dependence of the mSD decreased significantly with increasing distances, and also showed a considerably more pronounced angular dependence, especially for the smallest angles. The volume-averaging showed a similar radial dependence for both detectors: the correction had a maximal impact at 0.5 cm and then approached unity for larger distances, as expected. Concerning the angular dependence, the correction for the mSD was also similar to the one previously determined for the mDD (Rossi et al., 2020): a maximal impact was observed at 0 = 0 degrees, with values tending to unity for larger angles. In general, the volume-averaging was less pronounced for the mSD due to the smaller sensitive volume radius. After the application of the MC-based factors, dif-ferences between mDD dose rate measurements and TG-43 dose rate calculations ranged from -2.6% to +4.3%, with an absolute average difference of 1.0%. For the mSD, the differences ranged from -3.1% to +5.2%, with an absolute aver-age difference of 1.0%. For both detectors, all differences but one were within the combined uncertainty (k = 2). The dif-ferences of the mSD from the mDD ranged from -3.9% to +2.6%, with the vast majority of them being within the combined uncertainty (k = 2). For 0 - 0 degrees, the mDD was able to provide sufficiently accurate results even without the application of the MC-based beam quality correction factor, with differences to the TG-43 dose rate calculations from -1.9% to +3.4%, always within the combined uncertainty (k = 2).Conclusion: The mDD and the mSD showed consistent results and appear to be well suitable for measuring the dose rate around HDR 192Ir brachytherapy sources. MC characterization of the detectors response is needed to determine the beam quality correction factor and to account for energy dependence and/or volume-averaging, especially for the mSD. Our findings support the employment of the mDD and mSD for source QA, TPS verification and TG-43 parameters determination.
引用
收藏
页码:463 / 478
页数:16
相关论文
共 50 条
  • [31] Verification of high dose rate 192Ir source position during brachytherapy treatment
    Batic, M.
    Burger, J.
    Cindro, V.
    Kramberger, G.
    Mandic, I.
    Mikuz, M.
    Studen, A.
    Zavrtanik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3) : 206 - 208
  • [32] NPL's new absorbed dose standard for the calibration of HDR 192Ir brachytherapy sources
    Sander, T.
    Duane, S.
    Lee, N. D.
    Thomas, C. G.
    Owen, P. J.
    Bailey, M.
    Palmans, H.
    METROLOGIA, 2012, 49 (05) : S184 - S188
  • [33] Dosimetric characterization of round HDR 192Ir AccuBoost applicators for breast brachytherapy
    Rivard, Mark J.
    Melhus, Christopher S.
    Wazer, David E.
    Bricault, Raymond J., Jr.
    MEDICAL PHYSICS, 2009, 36 (11) : 5027 - 5032
  • [34] The Measurement of the Air-Kerma Rate in Air and a Solid Phantom with Ionization Chambers for a 192Ir HDR Brachytherapy Source
    Zeng, Jing
    Qu, Pengpeng
    Pang, Qingsong
    Wang, Ping
    CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 10821 - 10828
  • [35] Determination of the tissue attenuation factor along two major axes of a high dose rate (HDR) 192Ir source
    Cho, SH
    Muller-Runkel, R
    Hanson, WF
    MEDICAL PHYSICS, 1999, 26 (08) : 1492 - 1497
  • [36] Dose distribution around a low dose rate 192Ir seed source implanted in the brain
    Ghiassi-Nejad, M
    Jafarizadeh, M
    Rashidi, S
    Pooya, MH
    PHYSICA MEDICA, 2003, 19 (01) : 27 - 30
  • [37] On source models for 192Ir HDR brachytherapy dosimetry using model based algorithms
    Pantelis, Evaggelos
    Zourari, Kyveli
    Zoros, Emmanouil
    Lahanas, Vasileios
    Karaiskos, Pantelis
    Papagiannis, Panagiotis
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (11) : 4235 - 4246
  • [38] Measurement of absorbed dose-to-water for an HDR 192Ir source with ionization chambers in a sandwich setup
    Araki, Fujio
    Kouno, Tomohiro
    Ohno, Takeshi
    Kakei, Kiyotaka
    Yoshiyama, Fumiaki
    Kawamura, Shinji
    MEDICAL PHYSICS, 2013, 40 (09)
  • [39] The Application of Elliptic Cylindrical Phantom in Brachytherapy Dosimetric Study of HDR 192Ir Source
    Ahn, Woo Sang
    Park, Sung Ho
    Jung, Sang Hoon
    Choi, Wonsik
    Do Ahn, Seung
    Shin, Seong Soo
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [40] Dose perturbation effects by metal hip prosthesis in gynaecological 192Ir HDR brachytherapy
    Ab Shukor, N. S.
    Abdullah, R.
    Aziz, M. Z. Abdul
    Samson, D. O.
    Musarudin, M.
    APPLIED RADIATION AND ISOTOPES, 2023, 196