Detectability of Visual Field Defects in Glaucoma Using Moving Versus Static Stimuli for Perimetry

被引:0
作者
Gardiner, Stuart K. [1 ,2 ]
Mansberger, Steven L. [1 ]
机构
[1] Legacy Hlth, Devers Eye Inst, Portland, OR USA
[2] Devers Eye Inst, Legacy Res Inst, 1225 NE 2nd Ave, Portland, OR 97232 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2023年 / 12卷 / 08期
关键词
perimetry; glaucoma; visual psychophysics; VARIABILITY; THRESHOLD; STANDARD; MOTION;
D O I
10.1167/tvst.12.8.12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We have previously shown that using moving, instead of static, stimuli extends the effective dynamic range of automated perimetry in glaucoma. In this study, we further investigate the effect of using moving stimuli on the detectability of functional loss. Methods: We used two experimental perimetry paradigms to test 155 subjects with a diagnosis of glaucoma or glaucoma suspect, and 34 healthy control subjects. One test used stimuli moving parallel to the average nerve fiber bundle orientation at each location; the other used static stimuli. Algorithms were otherwise identical. Sensitivities to moving stimuli were transformed to the equivalent values for static stimuli based on a Bland-Altman plot. The proportions of locations outside age-corrected normative limits were compared, and test-retest variability was compared against defect depth for each stimulus type. Results: More tested locations were below the fifth percentile of the normative range for that location using static stimuli. However, among locations abnormal according to standard clinical perimetry on the same day, 19.2% were abnormal using static stimuli, versus 20.5% using moving stimuli (P = 0.372). Test-retest variability was 44% lower for moving stimuli across the range of defect depths. Conclusions: When compared with static automated perimetry and expressed on a common scale, moving stimuli extend the effective dynamic range and decrease variability, without decreasing the detectability of known functional defects. Translational Relevance: Moving stimuli provide a method to improve known problems of current clinical perimetry.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Usefulness of 10-2 Matrix Frequency Doubling Technology Perimetry for Detecting Central Visual Field Defects in Preperimetric Glaucoma Patients [J].
Jung, Younhea ;
Park, Hae-Young L. ;
Park, Yi Ryeung ;
Park, Chan Kee .
SCIENTIFIC REPORTS, 2017, 7
[42]   COURSE OF VISUAL-FIELD LOSS ON AUTOMATED PERIMETRY IN CHRONIC GLAUCOMA STABILIZED BY TRABECULECTOMY [J].
BOISSONNOT, M ;
HIRSCH, AL ;
ROVIRA, JC ;
RISSE, JF .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 1992, 15 (12) :645-650
[43]   Evaluation of the Consistency of Glaucomatous Visual Field Defects Using a Clustered SITA-Faster Protocol [J].
Tan, Jeremy C. K. ;
Phu, Jack ;
Go, Denise ;
Nguyen, Doan ;
Masselos, Katherine ;
Bank, Allan ;
Kalloniatis, Michael ;
Agar, Ashish .
OPHTHALMOLOGY, 2023, 130 (11) :1138-1148
[44]   COMPARISON OF THE OCULOKINETIC PERIMETRY GLAUCOMA SCREENER WITH 2 TYPES OF VISUAL-FIELD ANALYZER [J].
GREVE, M ;
CHISHOLM, IA .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1993, 28 (05) :201-206
[45]   Comparing a Head-Mounted Smartphone Visual Field Analyzer to Standard Automated Perimetry in Glaucoma: A Prospective Study [J].
Wang, Sean K. ;
Tran, Elaine M. ;
Yan, William ;
Kosaraju, Reshma ;
Sun, Yang ;
Chang, Robert T. .
JOURNAL OF GLAUCOMA, 2024, 33 (10) :742-747
[46]   Sensitivity of size I stimulus in achromatic automated perimetry for detection of glaucomatous visual field defects: a comparative analysis with short wavelength automated perimetry and standard automated perimetry (SITA) [J].
Lemos Mattos, Tessa de Cerqueira ;
Kasahara, Niro ;
Della Paolera, Mauricio ;
Cohen, Ralph ;
Mandia Junior, Carmo ;
de Almeida, Geraldo Vicente .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (02) :142-148
[47]   Location of Initial Visual Field Defects in Glaucoma and Their Modes of Deterioration [J].
Kim, Joon Mo ;
Kyung, Haksu ;
Shim, Seong Hee ;
Azarbod, Parham ;
Caprioli, Joseph .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) :7956-7962
[48]   Distribution and Progression of Visual Field Defects With Binocular Vision in Glaucoma [J].
Hashimoto, Shigeki ;
Matsumoto, Chota ;
Eura, Mariko ;
Okuyama, Sachiko ;
Nomoto, Hiroki ;
Tanabe, Fumi ;
Kayazawa, Tomoyasu ;
Iwase, Aiko ;
Shimomura, Yoshikazu .
JOURNAL OF GLAUCOMA, 2018, 27 (06) :519-524
[49]   Comparison of Visual Field Results of Humphrey Matrix Perimetry and Standard Automated Perimetry with SITA Strategy in Glaucoma and Ocular Hypertension Subjects [J].
Yilmaz, Pinar Topcu ;
Bozkurt, Banu ;
Irkec, Murat .
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02) :98-103
[50]   Does frequency doubling technology perimetry reliably detect neurological visual field defects? [J].
Fong, KCS ;
Byles, DB ;
Constable, PH .
EYE, 2003, 17 (03) :330-333