Detectability of Visual Field Defects in Glaucoma Using Moving Versus Static Stimuli for Perimetry

被引:0
|
作者
Gardiner, Stuart K. [1 ,2 ]
Mansberger, Steven L. [1 ]
机构
[1] Legacy Hlth, Devers Eye Inst, Portland, OR USA
[2] Devers Eye Inst, Legacy Res Inst, 1225 NE 2nd Ave, Portland, OR 97232 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2023年 / 12卷 / 08期
关键词
perimetry; glaucoma; visual psychophysics; VARIABILITY; THRESHOLD; STANDARD; MOTION;
D O I
10.1167/tvst.12.8.12
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We have previously shown that using moving, instead of static, stimuli extends the effective dynamic range of automated perimetry in glaucoma. In this study, we further investigate the effect of using moving stimuli on the detectability of functional loss. Methods: We used two experimental perimetry paradigms to test 155 subjects with a diagnosis of glaucoma or glaucoma suspect, and 34 healthy control subjects. One test used stimuli moving parallel to the average nerve fiber bundle orientation at each location; the other used static stimuli. Algorithms were otherwise identical. Sensitivities to moving stimuli were transformed to the equivalent values for static stimuli based on a Bland-Altman plot. The proportions of locations outside age-corrected normative limits were compared, and test-retest variability was compared against defect depth for each stimulus type. Results: More tested locations were below the fifth percentile of the normative range for that location using static stimuli. However, among locations abnormal according to standard clinical perimetry on the same day, 19.2% were abnormal using static stimuli, versus 20.5% using moving stimuli (P = 0.372). Test-retest variability was 44% lower for moving stimuli across the range of defect depths. Conclusions: When compared with static automated perimetry and expressed on a common scale, moving stimuli extend the effective dynamic range and decrease variability, without decreasing the detectability of known functional defects. Translational Relevance: Moving stimuli provide a method to improve known problems of current clinical perimetry.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Detectability of Visual Field Defects in Glaucoma With High-resolution Perimetry
    Numata, Takuya
    Matsumoto, Chota
    Okuyama, Sachiko
    Tanabe, Fumi
    Hashimoto, Shigeki
    Nomoto, Hiroki
    Shimomura, Yoshikazu
    JOURNAL OF GLAUCOMA, 2016, 25 (10) : 847 - 853
  • [2] Static Versus Kinetic Perimetry in Glaucomatous Visual Field Defects
    Rohrschneider, K.
    Scheuerle, A. F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [3] Threshold Automated Perimetry of the Full Visual Field in Patients With Glaucoma With Mild Visual Loss
    Wall, Michael
    Lee, Eric J.
    Wanzek, Robert J.
    Zamba, K. D.
    Turpin, Andrew
    Chong, Luke X.
    Marin-Franch, Ivan
    JOURNAL OF GLAUCOMA, 2019, 28 (11) : 997 - 1005
  • [4] Diffuse and localised visual field defects to automated perimetry in primary open angle glaucoma
    Mutlukan, E
    EYE, 1995, 9 : 745 - 750
  • [5] Detectability of Visual Field Defects using 0.5 Degree Interval in High Resolution Perimetry and OCT Findings
    Numata, Takuya
    Matsumoto, Chota
    Okuyama, Sachiko
    Takada, Sonoko
    Tanabe, Fumi
    Hashimoto, Shigeki
    Eura, Mariko
    Kayazawa, Tomoyasu
    Koike, Eiko
    Shimomura, Yoshikazu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [6] Using high-density perimetry to explore new approaches for characterizing visual field defects
    Marin-Franch, I.
    Wyatt, H. J.
    Swanson, W. H.
    VISION RESEARCH, 2023, 210
  • [7] Temporal Wedge Defects in Glaucoma: Structure/Function Correlation With Threshold Automated Perimetry of the Full Visual Field
    Wall, Michael
    Lee, Eric J.
    Wanzek, Robert J.
    Chong, Luke X.
    Turpin, Andrew
    JOURNAL OF GLAUCOMA, 2020, 29 (03) : 191 - 197
  • [8] Comparison of Matrix Perimetry With Octopus Perimetry for Assessing Glaucomatous Visual Field Defects
    Lan, Yu-Wen
    Hsieh, Jui-Wen
    Sun, Fang-Ju
    JOURNAL OF GLAUCOMA, 2011, 20 (02) : 126 - 132
  • [9] Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes
    Hu, Rongrong
    Wang, Chenkun
    Racette, Lyne
    PLOS ONE, 2017, 12 (05):
  • [10] Identification of functional visual field loss by automated static perimetry
    Frisen, Lars
    ACTA OPHTHALMOLOGICA, 2014, 92 (08) : 805 - 809