Low-Intensity Pulsed Ultrasound Neuromodulation of a Rodent's Spinal Cord Suppresses Motor Evoked Potentials

被引:6
|
作者
Tsehay, Yohannes [1 ]
Zeng, Yinuo [2 ]
Weber-Levine, Carly [1 ]
Awosika, Tolulope [1 ]
Kerensky, Max [2 ]
Hersh, Andrew M. [1 ]
Ou, Ze [2 ]
Jiang, Kelly [1 ]
Bhimreddy, Meghana [1 ]
Bauer, Stuart J. [2 ]
Theodore, John N.
Quiroz, Victor M. [2 ]
Suk, Ian [1 ]
Alomari, Safwan [1 ]
Sun, Junfeng
Tong, Shanbao [3 ]
Thakor, Nitish [2 ,4 ,5 ]
Doloff, Joshua C. [2 ,6 ,7 ,8 ]
Theodore, Nicholas [2 ,9 ,10 ]
Manbachi, Amir [11 ,12 ,13 ,14 ,15 ,16 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Neurosurg, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Sch Med, Baltimore, MD 21287 USA
[3] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[4] Natl Univ Singapore, Dept Biomed Engn, Singapore, Singapore
[5] Natl Univ Singapore, SINAPSE Inst, Singapore, Singapore
[6] Johns Hopkins Univ, Inst NanoBioTechnol, Dept Mat Sci & Engn, Baltimore, MD USA
[7] Johns Hopkins Univ, Sidney Kimmel Comprehens Canc Ctr, Dept Oncol, Div Canc Immunol,Sch Med, Baltimore, MD USA
[8] Johns Hopkins Univ, Bloomberg Kimmel Inst Canc Immunotherapy, Translat Tissue Engn Ctr, Sch Med, Baltimore, MD USA
[9] Johns Hopkins Univ, Sch Med, Dept Neurosurg, HEPIUS Innovat Lab, Baltimore, MD 21287 USA
[10] Johns Hopkins Univ, Sch Med, Dept Orthoped Surg, Baltimore, MD 21287 USA
[11] Dept Neurosurg, HEPIUS Innovat Lab, Baltimore, MD USA
[12] Dept Biomed Engn, Baltimore, MD USA
[13] Dept Mech Engn, Baltimore, MD USA
[14] Dept Elect & Comp Engn, Baltimore, MD USA
[15] Dept Anesthesiol, Baltimore, MD USA
[16] Dept Crit Care Med, Baltimore, MD USA
关键词
Low-intensity pulsed ultrasound; motor evoked potentials; neuromodulation; rat model; spinal cord injury; thoracic spine; FOCUSED ULTRASOUND; STIMULATION; INJURY;
D O I
10.1109/TBME.2022.3233345
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Here we investigate the ability of low-intensity ultrasound (LIUS) applied to the spinal cord to modulate the transmission of motor signals. Methods: Male adult Sprague-Dawley rats (n = 10, 250-300 g, 15 weeks old) were used in this study. Anesthesia was initially induced with 2% isoflurane carried by oxygen at 4 L/min via a nose cone. Cranial, upper extremity, and lower extremity electrodes were placed. A thoracic laminectomy was performed to expose the spinal cord at the T11 and T12 vertebral levels. A LIUS transducer was coupled to the exposed spinal cord, and motor evoked potentials (MEPs) were acquired each minute for either 5- or 10-minutes of sonication. Following the sonication period, the ultrasound was turned off and post-sonication MEPs were acquired for an additional 5 minutes. Results: Hindlimb MEP amplitude significantly decreased during sonication in both the 5- (p < 0.001) and 10-min (p = 0.004) cohorts with a corresponding gradual recovery to baseline. Forelimb MEP amplitude did not demonstrate any statistically significant changes during sonication in either the 5- (p = 0.46) or 10-min (p = 0.80) trials. Conclusion: LIUS applied to the spinal cord suppresses MEP signals caudal to the site of sonication, with recovery of MEPs to baseline after sonication. Significance: LIUS can suppress motor signals in the spinal cord and may be useful in treating movement disorders driven by excessive excitation of spinal neurons.
引用
收藏
页码:1992 / 2001
页数:10
相关论文
共 50 条
  • [21] Advances in the application of low-intensity pulsed ultrasound to mesenchymal stem cells
    Xia, Peng
    Shi, Yi
    Wang, Xiaoju
    Li, Xueping
    STEM CELL RESEARCH & THERAPY, 2022, 13 (01)
  • [22] Transesophageal versus transcranial motor evoked potentials to monitor spinal cord ischemia
    Tsuda, Kazumasa
    Shiiya, Norihiko
    Takahashi, Daisuke
    Ohkura, Kazuhiro
    Yamashita, Katsushi
    Kando, Yumi
    Arai, Yoshifumi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (02) : 509 - 517
  • [23] Effects of low-intensity pulsed ultrasound exposure on rats tibia periosteum
    Batista, Jaqueline M.
    Nakagaki, Wilson R.
    Soares, Evelise A.
    Camilli, Josse A.
    ANAIS DA ACADEMIA BRASILEIRA DE CIENCIAS, 2020, 92 (01):
  • [24] REINFORCEMENT OF MOTOR EVOKED-POTENTIALS IN PATIENTS WITH SPINAL-CORD INJURY
    HAYES, KC
    ALLATT, RD
    WOLFE, DL
    KASAI, T
    HSIEH, J
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, : 312 - 329
  • [25] Effects of Athermal Shortwave Diathermy Treatment on Somatosensory Evoked Potentials and Motor Evoked Potentials in Rats With Spinal Cord Injury
    Xie, Caizhong
    Li, Xiangzhe
    Fang, Lu
    Wang, Tong
    SPINE, 2019, 44 (13) : E749 - E758
  • [26] Low-intensity pulsed ultrasound reduces oxidative and endoplasmic reticulum stress in motor neuron cells
    Truong, Thi-Thuyet
    Huang, Chih-Chung
    Chiu, Wen-Tai
    ULTRASONICS, 2025, 146
  • [27] Proteomics Reveals the Effect of Low-Intensity Focused Ultrasound on Spasticity After Spinal Cord Injury
    Wang, Bin
    Zhao, Hongbo
    Chen, Moxian
    Chen, Shaochun
    Liao, Yehui
    Tang, Xin
    Ao, Lijuan
    Liu, Yao
    TURKISH NEUROSURGERY, 2023, 33 (01) : 77 - 86
  • [28] Peripheral nerve grafts in a spinal cord prosthesis result in regeneration and motor evoked potentials following spinal cord resection
    Nordblom, Jonathan
    Persson, Jonas K. E.
    Svensson, Mikael
    Mattsson, Per
    RESTORATIVE NEUROLOGY AND NEUROSCIENCE, 2009, 27 (04) : 285 - 295
  • [29] Effects of Low-Intensity Pulsed Ultrasound on Spinal Pseudarthrosis Created by Nicotine Administration A Model of Lumbar Posterolateral Pseucarthrosis in Rabbits
    Liao, Jen-Chung
    Chen, Wen-Jer
    Niu, Chi-Chien
    Chen, Lih-Hui
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (06) : 1043 - 1050
  • [30] The action of low-intensity pulsed ultrasound in bones of osteopenic rats
    Carvalho, DCL
    Cliquet, A
    ARTIFICIAL ORGANS, 2004, 28 (01) : 114 - 118