共 50 条
Low-Intensity Pulsed Ultrasound Neuromodulation of a Rodent's Spinal Cord Suppresses Motor Evoked Potentials
被引:6
|作者:
Tsehay, Yohannes
[1
]
Zeng, Yinuo
[2
]
Weber-Levine, Carly
[1
]
Awosika, Tolulope
[1
]
Kerensky, Max
[2
]
Hersh, Andrew M.
[1
]
Ou, Ze
[2
]
Jiang, Kelly
[1
]
Bhimreddy, Meghana
[1
]
Bauer, Stuart J.
[2
]
Theodore, John N.
Quiroz, Victor M.
[2
]
Suk, Ian
[1
]
Alomari, Safwan
[1
]
Sun, Junfeng
Tong, Shanbao
[3
]
Thakor, Nitish
[2
,4
,5
]
Doloff, Joshua C.
[2
,6
,7
,8
]
Theodore, Nicholas
[2
,9
,10
]
Manbachi, Amir
[11
,12
,13
,14
,15
,16
]
机构:
[1] Johns Hopkins Univ, Sch Med, Dept Neurosurg, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Sch Med, Baltimore, MD 21287 USA
[3] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[4] Natl Univ Singapore, Dept Biomed Engn, Singapore, Singapore
[5] Natl Univ Singapore, SINAPSE Inst, Singapore, Singapore
[6] Johns Hopkins Univ, Inst NanoBioTechnol, Dept Mat Sci & Engn, Baltimore, MD USA
[7] Johns Hopkins Univ, Sidney Kimmel Comprehens Canc Ctr, Dept Oncol, Div Canc Immunol,Sch Med, Baltimore, MD USA
[8] Johns Hopkins Univ, Bloomberg Kimmel Inst Canc Immunotherapy, Translat Tissue Engn Ctr, Sch Med, Baltimore, MD USA
[9] Johns Hopkins Univ, Sch Med, Dept Neurosurg, HEPIUS Innovat Lab, Baltimore, MD 21287 USA
[10] Johns Hopkins Univ, Sch Med, Dept Orthoped Surg, Baltimore, MD 21287 USA
[11] Dept Neurosurg, HEPIUS Innovat Lab, Baltimore, MD USA
[12] Dept Biomed Engn, Baltimore, MD USA
[13] Dept Mech Engn, Baltimore, MD USA
[14] Dept Elect & Comp Engn, Baltimore, MD USA
[15] Dept Anesthesiol, Baltimore, MD USA
[16] Dept Crit Care Med, Baltimore, MD USA
关键词:
Low-intensity pulsed ultrasound;
motor evoked potentials;
neuromodulation;
rat model;
spinal cord injury;
thoracic spine;
FOCUSED ULTRASOUND;
STIMULATION;
INJURY;
D O I:
10.1109/TBME.2022.3233345
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Objective: Here we investigate the ability of low-intensity ultrasound (LIUS) applied to the spinal cord to modulate the transmission of motor signals. Methods: Male adult Sprague-Dawley rats (n = 10, 250-300 g, 15 weeks old) were used in this study. Anesthesia was initially induced with 2% isoflurane carried by oxygen at 4 L/min via a nose cone. Cranial, upper extremity, and lower extremity electrodes were placed. A thoracic laminectomy was performed to expose the spinal cord at the T11 and T12 vertebral levels. A LIUS transducer was coupled to the exposed spinal cord, and motor evoked potentials (MEPs) were acquired each minute for either 5- or 10-minutes of sonication. Following the sonication period, the ultrasound was turned off and post-sonication MEPs were acquired for an additional 5 minutes. Results: Hindlimb MEP amplitude significantly decreased during sonication in both the 5- (p < 0.001) and 10-min (p = 0.004) cohorts with a corresponding gradual recovery to baseline. Forelimb MEP amplitude did not demonstrate any statistically significant changes during sonication in either the 5- (p = 0.46) or 10-min (p = 0.80) trials. Conclusion: LIUS applied to the spinal cord suppresses MEP signals caudal to the site of sonication, with recovery of MEPs to baseline after sonication. Significance: LIUS can suppress motor signals in the spinal cord and may be useful in treating movement disorders driven by excessive excitation of spinal neurons.
引用
收藏
页码:1992 / 2001
页数:10
相关论文