The Ability of Robot-Assisted Total Knee Arthroplasty in Matching the Efficiency of Its Conventional Counterpart at an Orthopaedic Specialty Hospital

被引:5
作者
Knee, Primary [1 ]
Meghpara, Michael M. [1 ]
Goh, Graham S. [1 ]
Magnuson, Justin A. [1 ]
Hozack, William J. [1 ]
Courtney, Maxwell [1 ]
Krueger, Chad A. [1 ,2 ]
机构
[1] Thomas Jefferson Univ, Rothman Orthopaed Inst, Philadelphia, PA USA
[2] Rothman Orthopaed Inst, 925 Chestnut St, Philadelphia, PA 19107 USA
关键词
total knee arthroplasty; robotic; operative time; turnover; learning curve; TOTAL JOINT ARTHROPLASTY; HIP-ARTHROPLASTY; LEARNING-CURVE; REVISION HIP; VOLUME;
D O I
10.1016/j.arth.2022.07.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Robot-assisted total knee arthroplasty (RA-TKA) has become a popular technology. Studies have investigated the learning curve for surgeons incorporating RA-TKA into practice, but less is known regarding the change in operative efficiency when introducing RA-TKA into a facility. The purpose of this study was to investigate the effects of RA-TKA on operative and turnover time at an orthopaedic specialty hospital.Methods: A total of 148 cases (74 RA-TKA and 74 conventional TKA [C-TKA]) performed by 2 surgeons with previous robotic experience were identified following the introduction of RA-TKA at our facility. Patient demographics, comorbidities, and operative times (ie, wheels-in to incision, incision to closure, closure to wheels-out, and turnover time) were recorded. Cumulative summation analyses were used to investigate learning curves of factors extraneous to surgeon proficiency with RA-TKA.Results: While RA-TKA had a slightly longer set up (3 minutes; range, 12-45), surgical (5 minutes; range, 33-118), and breakdown time (3 minutes; range, 2-7), there was no difference in turnover time between the groups. The learning curve for surgeon A was 6 robotic cases, whereas surgeon B demonstrated no learning curve. There was no identifiable learning curve for turnover time.Conclusion: There was a mean of 8 minutes of increased time required to perform a RA-TKA compared to C-TKA. However, these small increases for the RA-TKA group for set-up, surgical, and breakdown times are not likely to be clinically relevant compared to the C-TKA. It appears that the RA-TKA technology was able to be incorporated into this specialty hospital with minimal changes to surgical efficiency.(c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:72 / +
页数:9
相关论文
共 22 条
  • [1] Inflation-Adjusted Medicare Reimbursement for Revision Hip Arthroplasty Study Showing Significant Decrease from 2002 to 2019
    Acuna, Alexander J.
    Jella, Tarun K.
    Samuel, Linsen T.
    Schwarzkopf, Ran
    Fehring, Thomas K.
    Kamath, Atul F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (13) : 1212 - 1219
  • [2] Developing a High-efficiency Operating Room for Total Joint Arthroplasty in an Academic Setting
    Attarian, David E.
    Wahl, Jennie E.
    Wellman, Samuel S.
    Bolognesi, Michael P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (06) : 1832 - 1836
  • [3] A 90-day episode-of-care cost analysis of robotic-arm assisted total knee arthroplasty
    Cool, Christina L.
    Jacofsky, David J.
    Seeger, Kelly A.
    Sodhi, Nipun
    Mont, Michael A.
    [J]. JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2019, 8 (05) : 327 - 336
  • [4] Total Knee Arthroplasty Hospital Costs by Time-Driven Activity-Based Costing: Robotic vs Conventional
    Fang, Christopher J.
    Mazzocco, John C.
    Sun, Daniel C.
    Shaker, Jonathan M.
    Talmo, Carl T.
    Mattingly, David A.
    Smith, Eric L.
    [J]. ARTHROPLASTY TODAY, 2022, 13 : 43 - 47
  • [5] Improving Arthroplasty Efficiency and Quality Through Concentrating Service Volume by Complexity: Surviving the Medicare Policy Changes
    Iorio, Richard
    Peavy, Patrick R.
    Keyes, David W.
    Dempsey, Susan M.
    McCready, David O.
    Kang, James D.
    [J]. JOURNAL OF ARTHROPLASTY, 2021, 36 (09) : 3055 - 3059
  • [6] Robotics in Arthroplasty: A Comprehensive Review
    Jacofsky, David J.
    Allen, Mark
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (10) : 2353 - 2363
  • [7] Medicare Physician Fee Reimbursement for Revision Total Knee Arthroplasty Has Not Kept Up with Inflation from 2002 to 2019
    Jella, Tarun K.
    Acuna, Alexander J.
    Samuel, Linsen T.
    Schwarzkopf, Ran
    Fehring, Thomas K.
    Kamath, Atul F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2021, 103 (09) : 778 - 785
  • [8] Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning
    Kayani, Babar
    Konan, S.
    Huq, S. S.
    Tahmassebi, J.
    Haddad, F. S.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1132 - 1141
  • [9] Prevalence of Total Hip and Knee Replacement in the United States
    Kremers, Hilal Maradit
    Larson, Dirk R.
    Crowson, Cynthia S.
    Kremers, Walter K.
    Washington, Raynard E.
    Steiner, Claudia A.
    Jiranek, William A.
    Berry, Daniel J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (17) : 1386 - 1397
  • [10] Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030
    Kurtz, Steven
    Ong, Kevin
    Lau, Edmund
    Mowat, Fionna
    Halpern, Michael
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) : 780 - 785