Homogeneous electrochemiluminescence aptasensor based on hybridization chain reaction and magnetic separation assistance for Staphylococcus aureus

被引:11
|
作者
You, Shumin [1 ]
Li, Qiaoyin [1 ]
Chen, Haiyan [1 ]
Lin, Zhenyu [1 ]
Zhang, Shenghang [2 ,3 ]
Jiang, Xiaohua [2 ,4 ]
Qiu, Bin [1 ,2 ]
机构
[1] Fuzhou Univ, Key Lab Analyt Sci Food Safety & Biol, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] Xiamen Univ, Hosp 900, Affiliated Dongfang Hosp, Fujian Key Lab Aptamers Technol,Sch Med, Fuzhou 350025, Fujian, Peoples R China
[3] PLA, Hosp Joint Logist Support Force 900, Inst Clin Lab Med, Fuzhou 350025, Fujian, Peoples R China
[4] Shenzhen Polytech, Sch Mat & Enviromental Engn, Shenzhen 518055, Peoples R China
关键词
Aptasensor; Hybridization chain reaction; Staphylococcus aureus; Magnetic separation; SENSITIVE DETECTION; BACTERIA;
D O I
10.1016/j.microc.2022.108377
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Staphylococcus aureus(S. aureus) can cause a variety of diseases,so it is essential to provide the simple and responsive identification of bacterial pathogens in clinical treatment. In this work a homogeneous aptamer electrochemiluminescence biosensor for Staphylococcus aureus was developed assisted based on hybridization chain reaction and magnetic separation assistance. The ds (Probe DNA/Aptamer) is modified on the magnetic beads. In the presence of the target the target binds to the Aptamer in ds (Probe DNA/Aptamer) exposing the Probe DNA in the ds DNA. The exposed Probe DNA triggers HCR resulting in long DNA duplexes which can be simply and efficiently enriched for the luminescent molecule Ru(phen)32+. To reduce the possibility of false positive signals Exo III was added to cut unreacted dsDNA from the magnetic beads. The ECL intensity was linearly correlated with the logarithm of S. aureus concentration in the range of 10 CFU/mL -10 x 107 CFU/mL with a detection limit of 3 CFU/mL. The method developed in this work has good sensitivity and specificity and can well evaluate the concentration of Staphylococcus aureus in normal human serum and the results are consistent with the results obtained by the plate counting method.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A SERS aptasensor based on porous Au-NC nanoballoons for Staphylococcus aureus detection
    Xie, Beibei
    Wang, Zhi-Peng
    Zhang, Ruixue
    Zhang, Zhen
    He, Yun
    ANALYTICA CHIMICA ACTA, 2022, 1190
  • [22] A fluorescence aptasensor based on hybridization chain reaction for simultaneous detection of T-2 toxins and zearalenone1
    Zhu, Wenyan
    Ji, Guangna
    Chen, Ruipeng
    Xiang, Yunfeng
    Ji, Shuaifeng
    Zhang, Shengli
    Gao, Zhixian
    Liu, Hui
    Wang, Yu
    Han, Tie
    TALANTA, 2023, 255
  • [23] Electrochemiluminescence Immunosensor Based on Au Nanocluster and Hybridization Chain Reaction Signal Amplification for Ultrasensitive Detection of Cardiac Troponin I
    Zhu, Liping
    Ye, Jing
    Yan, Mengxia
    Zhu, Qiuju
    Wang, Shuang
    Huang, Jianshe
    Yang, Xiurong
    ACS SENSORS, 2019, 4 (10) : 2778 - 2785
  • [24] Ultrasensitive electrochemical biosensor for silver ion based on magnetic nanoparticles labeling with hybridization chain reaction amplification strategy
    Zhang, Yanli
    Li, Haiyan
    Chen, Meng
    Fang, Xiang
    Pang, Pengfei
    Wang, Hongbin
    Wu, Zhan
    Yang, Wenrong
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 249 : 431 - 438
  • [25] A colorimetric assay for Hg(II) based on the use of a magnetic aptamer and a hybridization chain reaction
    Lina Wang
    Fengya Liu
    Ning Sui
    Manhong Liu
    William W. Yu
    Microchimica Acta, 2016, 183 : 2855 - 2860
  • [26] A colorimetric assay for Hg(II) based on the use of a magnetic aptamer and a hybridization chain reaction
    Wang, Lina
    Liu, Fengya
    Sui, Ning
    Liu, Manhong
    Yu, William W.
    MICROCHIMICA ACTA, 2016, 183 (11) : 2855 - 2860
  • [27] A sensitive gold nanoparticle-based colorimetric aptasensor for Staphylococcus aureus
    Yuan, Jinglei
    Wu, Shijia
    Duan, Nuo
    Ma, Xiaoyuan
    Xia, Yu
    Chen, Jie
    Ding, Zhansheng
    Wang, Zhouping
    TALANTA, 2014, 127 : 163 - 168
  • [28] Streptavidin-exposed magnetic nanoparticles for lectin magnetic separation (LMS) of Staphylococcus aureus prior to three quantification strategies
    Yang, Guotai
    Huang, Min
    Wang, Yutong
    Chen, Guanhua
    Zhao, Yu
    Xu, Hengyi
    MICROCHIMICA ACTA, 2019, 186 (12)
  • [29] Hybridization Chain Reaction-Based Electrochemical Biosensors by Integrating the Advantages of Homogeneous Reaction and Heterogeneous Detection
    Xia, Ning
    Cheng, Jiayou
    Tian, Linxu
    Zhang, Shuo
    Wang, Yunqiu
    Li, Gang
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [30] Label-free ratiometric homogeneous electrochemical aptasensor based on hybridization chain reaction for facile and rapid detection of aflatoxin B1 in cereal crops
    Zhu, Chengxi
    Liu, Dong
    Li, Yuye
    Chen, Ting
    You, Tianyan
    FOOD CHEMISTRY, 2022, 373