Homogeneous electrochemiluminescence aptasensor based on hybridization chain reaction and magnetic separation assistance for Staphylococcus aureus

被引:11
|
作者
You, Shumin [1 ]
Li, Qiaoyin [1 ]
Chen, Haiyan [1 ]
Lin, Zhenyu [1 ]
Zhang, Shenghang [2 ,3 ]
Jiang, Xiaohua [2 ,4 ]
Qiu, Bin [1 ,2 ]
机构
[1] Fuzhou Univ, Key Lab Analyt Sci Food Safety & Biol, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] Xiamen Univ, Hosp 900, Affiliated Dongfang Hosp, Fujian Key Lab Aptamers Technol,Sch Med, Fuzhou 350025, Fujian, Peoples R China
[3] PLA, Hosp Joint Logist Support Force 900, Inst Clin Lab Med, Fuzhou 350025, Fujian, Peoples R China
[4] Shenzhen Polytech, Sch Mat & Enviromental Engn, Shenzhen 518055, Peoples R China
关键词
Aptasensor; Hybridization chain reaction; Staphylococcus aureus; Magnetic separation; SENSITIVE DETECTION; BACTERIA;
D O I
10.1016/j.microc.2022.108377
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Staphylococcus aureus(S. aureus) can cause a variety of diseases,so it is essential to provide the simple and responsive identification of bacterial pathogens in clinical treatment. In this work a homogeneous aptamer electrochemiluminescence biosensor for Staphylococcus aureus was developed assisted based on hybridization chain reaction and magnetic separation assistance. The ds (Probe DNA/Aptamer) is modified on the magnetic beads. In the presence of the target the target binds to the Aptamer in ds (Probe DNA/Aptamer) exposing the Probe DNA in the ds DNA. The exposed Probe DNA triggers HCR resulting in long DNA duplexes which can be simply and efficiently enriched for the luminescent molecule Ru(phen)32+. To reduce the possibility of false positive signals Exo III was added to cut unreacted dsDNA from the magnetic beads. The ECL intensity was linearly correlated with the logarithm of S. aureus concentration in the range of 10 CFU/mL -10 x 107 CFU/mL with a detection limit of 3 CFU/mL. The method developed in this work has good sensitivity and specificity and can well evaluate the concentration of Staphylococcus aureus in normal human serum and the results are consistent with the results obtained by the plate counting method.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Signal-on electrochemiluminescence aptasensor for bisphenol A based on hybridization chain reaction and electrically heated electrode
    Zhang, Huifang
    Luo, Fang
    Wang, Peilong
    Guo, Longhua
    Qiu, Bin
    Lin, Zhenyu
    BIOSENSORS & BIOELECTRONICS, 2019, 129 : 36 - 41
  • [2] An Ultrasensitive Upconversion Fluorescence Aptasensor Based on Graphene Oxide Release and Magnetic Separation for Staphylococcus aureus Detection
    Chen, Min
    Song, Yaqi
    Han, Lu
    Zhou, Dandan
    Wang, Yan
    Pan, Leiqing
    Tu, Kang
    FOOD ANALYTICAL METHODS, 2022, 15 (10) : 2791 - 2800
  • [3] Electrochemical Aptasensor based on the Hybridization Chain Reaction for Kanamycin Detection
    Zhang, Qinpu
    Li, Fang
    Li, Xinmiao
    Liu, Yunhong
    Han, Jing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (11): : 1 - 11
  • [4] Enzyme-free hybridization chain reaction-based signal amplification strategy for the sensitive detection of Staphylococcus aureus
    Tang, Jie
    Wang, Zefeng
    Zhou, Jiaqi
    Lu, Qiujun
    Deng, Le
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 215 : 41 - 47
  • [5] Portable detection of Staphylococcus aureus using personal glucose meter based on hybridization chain reaction strategy
    Yang, Yuemeng
    Wu, Tingting
    Xu, Li-Ping
    Zhang, Xueji
    TALANTA, 2021, 226
  • [6] Fluorescent aptasensor for highly sensitive detection of Staphylococcus aureus based on dual-amplification strategy by integrating DNA walking and hybridization chain reaction
    Zhang, Jialin
    Mao, Biyao
    Fan, Yaqi
    Zhou, Ming
    Wen, Herui
    Huang, Bin
    Lu, Kangqiang
    Ren, Jiali
    TALANTA, 2024, 270
  • [7] Recent Advancement in the development of hybridization chain reaction-based electrochemiluminescence biosensors
    Sun, Ting
    Du, Jia
    Li, Zhuo
    Zhao, Feng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (05):
  • [8] Tetrahedral DNA probe coupling with hybridization chain reaction for competitive thrombin aptasensor
    Chen, Ying-Xu
    Huang, Ke-Jing
    He, Liu-Liu
    Wang, Yi-Han
    BIOSENSORS & BIOELECTRONICS, 2018, 100 : 274 - 281
  • [9] Highly sensitive homogeneous electrochemiluminescence biosensor for microRNA-21 based on cascaded signal amplification of target-induced hybridization chain reaction and magnetic assisted enrichment
    Xu, Yunpeng
    Zhang, Yanzi
    Sui, Xiaolu
    Zhang, Aisha
    Liu, Xinguang
    Lin, Zhenyu
    Chen, Jihong
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 344
  • [10] Fluorescence Detection of Telomerase Activity Based on Signal Amplification of Hybridization Chain Reaction Combining with Magnetic Separation
    Zhang Jiayu
    Zhou Xiaoyu
    Zhou Man
    Jia Hongxia
    ACTA CHIMICA SINICA, 2016, 74 (06) : 513 - 517