Multi-commutated flow system for inorganic selenium speciation in infusion tea samples by chemical vapor generation atomic fluorescence spectrometry

被引:8
|
作者
Portugal, Lindomar A. [1 ]
Palacio, Edwin [1 ]
Frizzarin, Rejane [1 ]
Neto, Joao H. Santos [2 ,3 ]
Cerda, Victor [4 ]
Ferreira, Sergio L. C. [2 ,3 ]
机构
[1] Univ Balearic Isl, E-07122 Palma De Mallorca, Spain
[2] Univ Fed Bahia, Inst Quim, Campus Ondina, BR-40170270 Salvador, BA, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, Energia & Ambiente, BR-40170115 Salvador, BA, Brazil
[4] Sciware Syst SL, Bunyola 07193, Spain
关键词
Selenium; Teas; Atomic fluorescence spectrometry; MSFIA; LOV; HYDRIDE GENERATION; ABSORPTION-SPECTROMETRY; SEQUENTIAL DETERMINATION; MSFIA SYSTEM; SE(IV); SE(VI); OPTIMIZATION; REDUCTION;
D O I
10.1016/j.talanta.2022.123897
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work proposes an automated strategy for the inorganic selenium speciation in infusion tea samples, employing an MSFIA-CVG-AFS system and sodium tetrahydroborate for chemical vapor generation. The sele-nium total is determined after an online prereduction step of selenium (VI) to selenium (IV) in alkaline media, using a UV reactor with a 15 W Hg lamp. Selenium (IV) is quantified directly on the sample, and selenium (VI) is determined by the difference between the total selenium and selenium (IV) concentrations. The optimization of the chemical parameters: hydrochloric acid - hydrobromide acid solution concentration, potassium iodide concentration, sodium hydroxide concentration, and sodium tetrahydroborate concentration was performed using a (24-1) two-level fractional factorial design. The validation parameters were determined for total selenium and selenium (IV), and the results found were: limits of detection and quantification of 0.05 and 0.18 mu g L-1, respectively; a linear range of 0.18-5.0 mu g L-1, precision expressed as the relative standard deviation of 2.1% for a sample number of 10, for both analytes. The system allows the speciation analysis with an injection throughput of 15 injections per hour. This analytical method was applied for inorganic selenium speciation in nine infusions of tea samples purchased commercially in supermarkets in Palma de Mallorca City, Spain. The concentrations of selenium (IV) and total selenium varied from 0.2 to 0.6 mu g L-1 and 0.4-2.0 mu g L-1, respectively. The accuracy method was evaluated using spike tests, and the recoveries achieved varied from 91 to 111%.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Speciation of inorganic selenium using flow injection hydride generation atomic fluorescence spectrometry
    Bryce, DW
    Izquierdo, A
    DeCastro, MDL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (12) : 1059 - 1063
  • [2] A MSFIA system for selenium speciation by atomic fluorescence spectrometry
    Serra, Antonio M.
    Estela, Jose M.
    Cerda, Victor
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (11) : 1858 - 1862
  • [3] Speciation of Organic and Inorganic Selenium in Selenium-enriched Eggs by Hydride Generation Atomic Fluorescence Spectrometry
    Sun, Hanwen
    Feng, Bo
    FOOD ANALYTICAL METHODS, 2011, 4 (02) : 240 - 244
  • [4] Arsenic Speciation in Drinking Tea Samples by Hydride Generation Atomic Fluorescence Spectrometry
    Cai, Longfei
    Xu, Chunxiu
    Zhong, Minghua
    Wu, Yunying
    Zheng, Shufen
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (14) : 8169 - 8172
  • [5] Speciation of Organic and Inorganic Selenium in Selenium-enriched Eggs by Hydride Generation Atomic Fluorescence Spectrometry
    Hanwen Sun
    Bo Feng
    Food Analytical Methods, 2011, 4 : 240 - 244
  • [6] Determination of total inorganic arsenic in water samples by cadmium ion assisted photochemical vapor generation-atomic fluorescence spectrometry
    Zhou, Jing
    Deng, Dongyan
    Su, Yingying
    Lv, Yi
    MICROCHEMICAL JOURNAL, 2019, 146 : 359 - 365
  • [7] Determination of Selenium in Plant Samples by Hydride Generation Atomic Fluorescence Spectrometry
    Gou Ti-zhone
    Tang Wen-hua
    Zhang Wen-hua
    Liu Shao-you
    Wu Lin-dong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (05) : 1401 - 1404
  • [8] Multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry
    Semenova, NV
    Leal, LO
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2003, 486 (02) : 217 - 225
  • [9] Application of flow injection-green chemical vapor generation-atomic fluorescence spectrometry to ultrasensitive mercury speciation analysis of water and biological samples
    Zhang, Ruoxi
    Peng, Mengting
    Zheng, Chengbin
    Xu, Kailai
    Hou, Xiandeng
    MICROCHEMICAL JOURNAL, 2016, 127 : 62 - 67
  • [10] Chemical vapor generation coupled with atomic fluorescence spectrometry for the determination of manganese in food samples
    Zeng, Chujie
    Qin, Peipei
    Lan, Liling
    Wei, Haishi
    Wu, Wenfeng
    MICROCHEMICAL JOURNAL, 2017, 131 : 31 - 35