Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol

被引:13
|
作者
Schmitt, Niclas [1 ]
Wucherpfennig, Lena [2 ]
Rotkopf, Lukas T. [3 ]
Sawall, Stefan [4 ]
Kauczor, Hans-Ulrich [2 ]
Bendszus, Martin [1 ]
Moehlenbruch, Markus A. [1 ]
Schlemmer, Heinz-Peter [3 ]
Vollherbst, Dominik F. [1 ]
机构
[1] Heidelberg Univ Hosp, Dept Neuroradiol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol, Neuenheimer Feld 420, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Div Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[4] German Canc Res Ctr, Div Xray Imaging & Computed Tomog, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
Metal artifact reduction; Coils; Photon-counting CT; Aneurysm; Brain imaging; COMPUTED-TOMOGRAPHY;
D O I
10.1007/s00330-022-09073-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). Methods A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). Results Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 +/- 7.89 Hounsfield units (HU) versus 90.35 +/- 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 +/- 0.37 and 3.70 +/- 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 +/- 0.43 and 3.18 +/- 0.34; p < 0.001). Conclusion PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study.
引用
收藏
页码:803 / 811
页数:9
相关论文
共 50 条
  • [41] Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
    Rajendran, Kishore
    Voss, Benjamin A.
    Zhou, Wei
    Tao, Shengzhen
    DeLone, David R.
    Lane, John, I
    Weaver, Jayse M.
    Carlson, Matthew L.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 91 - 100
  • [42] Low-contrast detectability of photon-counting-detector CT at different scan modes and image types in comparison with energy-integrating-detector CT
    Fan, Mingdong
    Zhou, Zhongxing
    Wellinghoff, Jarod
    Mccollough, Cynthia H.
    Yu, Lifeng
    JOURNAL OF MEDICAL IMAGING, 2024, 11
  • [43] Assessing beam hardening artifacts in coronary stent imaging using different CT acquisition parameters on photon-counting detector computed tomography
    Adolf, Rafael
    Ried, Isabelle
    Will, Albrecht
    Hendrich, Eva
    Bressem, Keno
    Engel, Leif-Christoph
    Hadamitzky, Martin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025,
  • [44] Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT
    Stephan Rau
    Alexander Rau
    Thomas Stein
    Muhammad Taha Hagar
    Sebastian Faby
    Fabian Bamberg
    Jakob Weiss
    La radiologia medica, 2024, 129 : 669 - 676
  • [45] Value of virtual non-contrast images to identify uncomplicated cystic renal lesions: photon-counting detector CT vs. dual-energy integrating detector CT
    Rau, Stephan
    Rau, Alexander
    Stein, Thomas
    Hagar, Muhammad Taha
    Faby, Sebastian
    Bamberg, Fabian
    Weiss, Jakob
    RADIOLOGIA MEDICA, 2024, 129 (04): : 585 - 597
  • [46] Radiation Dose Reduction in Contrast-Enhanced Abdominal CT: Comparison of Photon-Counting Detector CT with 2nd Generation Dual-Source Dual-Energy CT in an oncologic cohort
    Wrazidlo, Robin
    Walder, Lukas
    Estler, Arne
    Gutjahr, Ralf
    Schmidt, Bernhard
    Faby, Sebastian
    Fritz, Jan
    Nikolaou, Konstantin
    Horger, Marius
    Hagen, Florian
    ACADEMIC RADIOLOGY, 2023, 30 (05) : 855 - 862
  • [47] Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction
    Zhang, Huan
    Xing, Yue
    Wang, Lingyun
    Hu, Yangfan
    Xu, Zhihan
    Chen, Haoda
    Lu, Junjie
    Yang, Jiarui
    Ding, Bei
    Hu, Weiguo
    Zhong, Jingyu
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, : 1891 - 1903
  • [48] Inter-reader agreement of pancreatic adenocarcinoma resectability assessment with photon counting versus energy integrating detector CT
    Kim, Jesi
    Mabud, Tarub
    Huang, Chenchan
    del Hoyo, Juan Lloret
    Petrocelli, Robert
    Vij, Abhinav
    Dane, Bari
    ABDOMINAL RADIOLOGY, 2024, 49 (09) : 3149 - 3157
  • [49] Universal 120-kV Dual-Source Ultra-High Pitch Protocol on the Photon-Counting CT System for Pediatric Abdomen of All Sizes: A Phantom Investigation Comparing With Energy-Integrating CT
    Zhou, Wei
    Huo, Donglai
    Browne, Lorna P.
    Zhou, Xin
    Weinman, Jason
    INVESTIGATIVE RADIOLOGY, 2024, 59 (10) : 719 - 726
  • [50] Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT
    Rajendran, Kishore
    Bruesewitz, Michael
    Swicklik, Joseph
    Ferrero, Andrea
    Thorne, Jamison
    Yu, Lifeng
    McCollough, Cynthia
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11)