Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol

被引:13
|
作者
Schmitt, Niclas [1 ]
Wucherpfennig, Lena [2 ]
Rotkopf, Lukas T. [3 ]
Sawall, Stefan [4 ]
Kauczor, Hans-Ulrich [2 ]
Bendszus, Martin [1 ]
Moehlenbruch, Markus A. [1 ]
Schlemmer, Heinz-Peter [3 ]
Vollherbst, Dominik F. [1 ]
机构
[1] Heidelberg Univ Hosp, Dept Neuroradiol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol, Neuenheimer Feld 420, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Div Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[4] German Canc Res Ctr, Div Xray Imaging & Computed Tomog, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
Metal artifact reduction; Coils; Photon-counting CT; Aneurysm; Brain imaging; COMPUTED-TOMOGRAPHY;
D O I
10.1007/s00330-022-09073-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). Methods A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). Results Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 +/- 7.89 Hounsfield units (HU) versus 90.35 +/- 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 +/- 0.37 and 3.70 +/- 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 +/- 0.43 and 3.18 +/- 0.34; p < 0.001). Conclusion PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study.
引用
收藏
页码:803 / 811
页数:9
相关论文
共 50 条
  • [21] Image Quality and Radiation Dose of CTPA With Iodine Maps: A Prospective Randomized Study of High-Pitch Mode Photon-Counting Detector CT Versus Energy-Integrating Detector CT
    Pannenbecker, Pauline
    Heidenreich, Julius F.
    Grunz, Jan-Peter
    Huflage, Henner
    Gruschwitz, Philipp
    Patzer, Theresa S.
    Feldle, Philipp
    Bley, Thorsten A.
    Petritsch, Bernhard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (02)
  • [22] Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study
    Zhou, W.
    Lane, J. I.
    Carlson, M. L.
    Bruesewitz, M. R.
    Witte, R. J.
    Koeller, K. K.
    Eckel, L. J.
    Carter, R. E.
    McCollough, C. H.
    Leng, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (09) : 1733 - 1738
  • [23] Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
    Frings, Marko
    Welsner, Matthias
    Mousa, Christin
    Zensen, Sebastian
    Salhoefer, Luca
    Meetschen, Mathias
    Beck, Nikolas
    Bos, Denise
    Westhoelter, Dirk
    Wienker, Johannes
    Taube, Christian
    Umutlu, Lale
    Schaarschmidt, Benedikt M.
    Forsting, Michael
    Haubold, Johannes
    Sutharsan, Sivagurunathan
    Opitz, Marcel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [24] A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT
    Kammerling, Nina
    Tesselaar, Erik
    Booij, Ronald
    Fornander, Lotta
    Persson, Anders
    Farnebo, Simon
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 173
  • [25] An Intra-Individual Comparison of Low-keV Photon-Counting CT versus Energy-Integrating-Detector CT Angiography of the Aorta
    Hennes, Jan-Lucca
    Huflage, Henner
    Grunz, Jan-Peter
    Hartung, Viktor
    Augustin, Anne Marie
    Patzer, Theresa Sophie
    Pannenbecker, Pauline
    Petritsch, Bernhard
    Bley, Thorsten Alexander
    Gruschwitz, Philipp
    DIAGNOSTICS, 2023, 13 (24)
  • [26] Photon- Counting Detector CT Versus Energy- Integrating Detector CT of the Lumbar Spine: Comparison of Radiation Dose and Image Quality
    Marth, Adrian A.
    Marcus, Roy P.
    Feuerriegel, Georg C.
    Nanz, Daniel
    Sutter, Reto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (01)
  • [27] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [28] Comparison of spectral CT imaging methods based a photon-counting detector: Experimental study
    Lee, Youngjin
    Lee, Seungwan
    Kim, Hee-Joung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 815 : 68 - 74
  • [29] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22) : 6709 - 6727
  • [30] Spectral Shaping Via Tin Prefiltration in Ultra-High-Resolution Photon-Counting and Energy-Integrating Detector CT of the Temporal Bone
    Grunz, Jan-Peter
    Heidenreich, Julius Frederik
    Lennartz, Simon
    Weighardt, Jens Philipp
    Bley, Thorsten Alexander
    Erguen, Sueleyman
    Petritsch, Bernhard
    Huflage, Henner
    INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 819 - 825