Energy, exergy, exergoeconomic and exergoenvironmental analyses of a hybrid renewable energy system with hydrogen fuel cells

被引:17
作者
Qi, Xinrui [1 ]
Kochan, Orest [2 ]
Ma, Zhenjun [3 ]
Siarry, Patrick [4 ]
Krolczyk, Grzegorz [6 ]
Li, Z. [5 ,6 ]
机构
[1] Ocean Univ China, Sch Engn, Qingdao 266100, Peoples R China
[2] Lviv Polytech Natl Univ, Dept Telecommun, UA-79013 Lvov, Ukraine
[3] Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW 2522, Australia
[4] Univ Paris Est Creteil Val De Marne, Lab Images Signals & Intelligent Syst, F-94010 Creteil, France
[5] Donghai Lab, Zhoushan 316021, Zhejiang, Peoples R China
[6] Opole Univ Technol, Fac Mech Engn, PL-45758 Opole, Poland
关键词
Exergoeconomic; Exergoenvironmental analysis; Renewable energy systems; Energy storage; SOLAR POWER; HEAT; CYCLE; OPTIMIZATION; PERFORMANCE; MULTIGENERATION; COLLECTORS; DESIGN; CPV/T;
D O I
10.1016/j.ijhydene.2023.07.163
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, the energy, exergy, exergoeconomic and exergoenvironmental (4E) analyses of a cogeneration system that combines photovoltaic thermal panels (PV/T), evacuated tube solar collectors, an organic Rankine cycle (ORC) and energy storage systems are performed. The cogeneration model is built to meet the load demand of independent houses in remote areas and avoids excessive consumption of traditional energy and environmental pollution. Here, the exergoenvironmental analysis adopts the Eco-indicator-99 method and the all life cycle assessment method is used to calculate the environmental impact of each component. Two comparative studies are conducted to the 4E analyses. The first one compares the comprehensive performance of the battery storage and hydrogen production for energy storage. The results indicate that the cogeneration system using both batteries and hydrogen production for energy storage has the best overall performance. According the exergoeconomic and exergoenvironmental analyses, its environmental impact is 23.6% lower than the cogeneration system using batteries alone and the PV/T can be fully utilized. In addition, the total cost rate is 6.2% lower than the cogeneration system using hydrogen production alone. The second case investigates the effect of adding the evacuated tube solar collectors between the PV/T and ORC on the cogeneration system. The analysis results demonstrate that the evacuated tube solar collectors can increase the heat source temperature of the ORC to increase the power generation of the ORC by 37.14%; however, the total cost rate of the cogeneration system increases by 3.7% and the environmental impact rate increases by 19.8%.(c) 2023 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:617 / 634
页数:18
相关论文
共 69 条
[41]   Applications of evacuated tubes collector to harness the solar energy: a review [J].
Mevada, Dinesh ;
Panchal, Hitesh ;
ElDinBastawissi, Hagar Alm ;
Elkelawy, Medhat ;
Sadashivuni, Kishorkumar ;
Ponnamma, Deepalekshmi ;
Thakar, Nishant ;
Sharshir, S. W. .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2019, 43 (01) :344-361
[42]   Exergoenvironmental analysis for evaluation of the environmental impact of energy conversion systems [J].
Meyer, Lutz ;
Tsatsaronis, George ;
Buchgeister, Jens ;
Schebek, Liselotte .
ENERGY, 2009, 34 (01) :75-89
[43]   Modified exergy and modified exergoeconomic analyses of a solar based biomass co-fired cycle with hydrogen production [J].
Moharramian, Anahita ;
Soltani, Saeed ;
Rosen, Marc A. ;
Mahmoudi, S. M. S. ;
Bhattacharya, Tanushree .
ENERGY, 2019, 167 :715-729
[44]   Multi-objective optimization of a biomass gasification to generate electricity and desalinated water using Grey Wolf Optimizer and artificial neural network [J].
Musharavati, Farayi ;
Khoshnevisan, Alireza ;
Alirahmi, Seyed Mojtaba ;
Ahmadi, Pouria ;
Khanmohammadi, Shoaib .
CHEMOSPHERE, 2022, 287
[45]   Comparison of optimum design, sizing, and economic analysis of standalone photovoltaic/battery without and with hydrogen production systems [J].
Nordin, Nur Dalilah ;
Rahman, Hasimah Abdul .
RENEWABLE ENERGY, 2019, 141 :107-123
[46]   Energy and exergy efficiencies enhancement analysis of integrated photovoltaic-based energy systems [J].
Ogbonnaya, C. ;
Turan, A. ;
Abeykoon, C. .
JOURNAL OF ENERGY STORAGE, 2019, 26
[47]   Techno-economic assessment of integrated spectral-beam-splitting photovoltaic-thermal (PV-T) and organic Rankine cycle (ORC) systems [J].
Peacock, Joshua ;
Huang, Gan ;
Song, Jian ;
Markides, Christos N. .
ENERGY CONVERSION AND MANAGEMENT, 2022, 269
[48]   Exergy of undiluted thermal radiation [J].
Petela, R .
SOLAR ENERGY, 2003, 74 (06) :469-488
[49]   EXERGETIC ANALYSIS OF HYBRID PHOTOVOLTAIC - THERMAL SOLAR COLLECTORS COUPLED TO ORGANIC RANKINE CYCLES [J].
Pinto, Clara ;
Mady, Carlos Eduardo .
CIVIL AND ENVIRONMENTAL ENGINEERING REPORTS, 2018, 28 (04) :1-12
[50]   RETRACTED: Sustainability analysis of a hybrid renewable power system with battery storage for islands application [J].
Qi, Xinrui ;
Wang, Jianmei ;
Krolczyk, Grzegorz ;
Gardoni, Paolo ;
Li, Zhixiong .
JOURNAL OF ENERGY STORAGE, 2022, 50