A Combined Use of Custom-Made Partial Pelvic Replacement and Proximal Femur Megaprosthesis in the Treatment of Severe Bone Loss after Multiple Total Hip Arthroplasty Revisions

被引:1
|
作者
Fiore, Michele [1 ]
Paolucci, Azzurra [1 ]
Zunarelli, Renato [1 ]
Bortoli, Marta [1 ]
Montanari, Andrea [1 ]
Pace, Andrea [1 ]
Di Prinzio, Lorenzo [1 ]
Parisi, Stefania Claudia [1 ]
De Cristofaro, Roberto [1 ]
De Paolis, Massimiliano [1 ]
Sambri, Andrea [1 ]
机构
[1] IRCCS Azienda Osped Univ Bologna, Orthoped & Traumatol Unit, I-40138 Bologna, Italy
来源
PROSTHESIS | 2023年 / 5卷 / 04期
关键词
severe bone loss; revision hip arthroplasty; custom-made; megaprosthesis; silver; FEMORAL REPLACEMENT; FOLLOW-UP; ACETABULAR COMPONENTS; ENDOPROSTHETIC REPLACEMENT; RESECTION ARTHROPLASTY; SURVIVORSHIP ANALYSIS; IMPLANTS; RECONSTRUCTION; MANAGEMENT; DEFECTS;
D O I
10.3390/prosthesis5040076
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Hip arthroplasty failures (either septic or aseptic) often require multiple revisions, thus leading to severe bone defects. The most common reconstruction methods do not allow the management of severe defects. For this reason, in recent years, techniques borrowed from surgical oncology have been applied in the field of revision surgery to deal with both acetabular and femoral bone losses. In this article, two cases of severe bone deficiency following multiple hip arthroplasty revisions that were treated with a custom-made hip prosthesis combined with a proximal femur megaprosthesis are presented. Both implants were silver coated. A review of the literature was conducted to analyze similar cases treated with either a custom-made prosthesis or a proximal femur megaprosthesis. At the 2-year follow-up, all prostheses were in site without clinical or radiographic signs of implant loosening. No postoperative complications occurred. At the last follow-up, both patients resumed their daily life activities with an MSTS score of 23 and 21, respectively. The combined approach of a proximal femur megaprosthesis with a custom-made partial pelvic replacement is a solution that allows severe bone deficiency cases to be tackled with good functional results. Additionally, silver coating may help prevent recurrence of infection.
引用
收藏
页码:1093 / 1110
页数:18
相关论文
共 10 条
  • [1] Proximal femoral replacement in contemporary revision total hip arthroplasty for severe femoral bone loss
    Viste, A.
    Perry, K. I.
    Taunton, M. J.
    Hanssen, A. D.
    Abdel, M. P.
    BONE & JOINT JOURNAL, 2017, 99B (03) : 325 - 329
  • [2] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    Froeschen, F. S.
    Randau, T. M.
    Hischebeth, G. T. R.
    Gravius, N.
    Gravius, S.
    Walter, S. G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) : 263 - 273
  • [3] Acetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature
    Chiarlone, Francesco
    Zanirato, Andrea
    Cavagnaro, Luca
    Alessio-Mazzola, Mattia
    Felli, Lamberto
    Burastero, Giorgio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 415 - 424
  • [4] Primary shoulder arthroplasty using a custom-made hip-inspired implant for the treatment of advanced glenohumeral arthritis in the presence of severe glenoid bone loss
    Chammaa, Ramsey
    Uri, Ofir
    Lambert, Simon
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (01) : 101 - 107
  • [5] Custom-made total ankle arthroplasty with patient-specific instrumentation for severe bone loss conditions: a case series
    Faldini, Cesare
    Mazzotti, Antonio
    Langone, Laura
    Arceri, Alberto
    Bonelli, Simone
    Zielli, Simone Ottavio
    Artioli, Elena
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01) : 379 - 387
  • [6] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    F. S. Fröschen
    T. M. Randau
    G. T. R. Hischebeth
    N. Gravius
    S. Gravius
    S. G. Walter
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 263 - 273
  • [7] Management of peri-prosthetic joint infection and severe bone loss after total hip arthroplasty using a long-stemmed cemented custom-made articulating spacer (CUMARS)
    Quayle, J.
    Barakat, A.
    Klasan, A.
    Mittal, A.
    Chan, G.
    Gibbs, J.
    Edmondson, M.
    Stott, P.
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [8] Strategies for the planning of complex shoulder arthroplasty: Use of a custom-made glenoid component in reverse shoulder arthroplasty for a neglected posterior fracture dislocation of the shoulder with malunited scapula fractures and severe eccentric glenoid bone loss
    Virani, Siddharth
    Shah, Nikki
    Assiotis, Angelos
    Rumian, Adam
    Uppal, Harpal
    SHOULDER & ELBOW, 2023, 15 (3_SUPPL) : 110 - 116
  • [9] High periprosthetic bone mineral density measured in immediate postoperative period may not guarantee less periprosthetic bone loss in the proximal femur after cementless total hip arthroplasty - A retrospective study
    Fu, Guangtao
    Ma, Yuanchen
    Liao, Junxing
    Xue, Yunlian
    Li, Mengyuan
    Li, Qingtian
    Deng, Zhantao
    Zheng, Qiujian
    ARTHROPLASTY, 2020, 2 (01)
  • [10] Using personalized 3D printed Titanium sleeve-prosthetic composite for reconstruction of severe segmental bone loss of proximal femur in revision total hip arthroplasty A case report
    Wang, Xingshan
    Xu, Hui
    Zhang, Ji
    MEDICINE, 2020, 99 (03)