Impartial Sequential Model Predictive Control of Parallel T-Type Rectifiers for Power Sharing and Circulating Current Elimination

被引:3
作者
Long, Bo [1 ,2 ,3 ,4 ]
Zhang, Jiahao [1 ,2 ,3 ,4 ]
Mao, Wenze [1 ,2 ,3 ,4 ]
Rodriguez, Jose [5 ]
Guerrero, Josep M. [6 ]
Chong, Kil To [7 ]
机构
[1] Univ Elect Sci & Technol China UESTC, Yangtze Delta Reg Inst Huzhou, Huzhou 313001, Peoples R China
[2] UESTC, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[3] UESTC, Inst Elect & Informat Engn, Huzhou 523808, Guangdong, Peoples R China
[4] Shenyang Univ Technol, MOE, Key Lab Special Machine & High Voltage Apparat, Shenyang 110870, Peoples R China
[5] Univ Andres Bello, Fac Engn, Santiago 8370146, Chile
[6] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[7] Jeonbuk Natl Univ, Dept Elect & Informat Engn, Jeonju 54896, South Korea
关键词
Common-mode voltage (CMV); impartial sequential model predictive control (ISMPC); neutral-point voltage balancing; parallel three-level T-type rectifiers (3LT2Rs); power sharing; zero-sequence circulating current (ZSCC); DEADBEAT CONTROL STRATEGY; CURRENT SUPPRESSION; CONVERTERS;
D O I
10.1109/JESTPE.2023.3277192
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A parallel T-type rectifier connection is often required to improve the system capacity and stability in high-power applications. However, the parallel rectifier faces the challenges of zero-sequence circulating current (ZSCC) elimination, neutral-point (NP) voltage balance, dc voltage stability, and power sharing. First, to solve the multiobjective optimization problem of two parallel three-level T-type rectifiers with LCL filters (LCL-3LT(2) Rs), a double closed-loop control scheme is adopted. In this scheme, an impartial sequential model predictive control (ISMPC) is proposed as the inner loop controller for ZSCC elimination and NP voltage balance, and an adaptive droop control with voltage feedforward is designed as the outer loop controller to achieve dc voltage stability and power sharing for each rectifier based on its capacity. Second, the main influencing factors of ZSCC in LCL-3LT(2)Rs are analyzed, and ZSCC elimination is considered as one control objective in ISMPC. Finally, ISMPC is proposed to solve the problem that sequential model predictive control (SMPC) could not select the optimal solution due to the fixed priority and the excessive process of only controlling a single objective. The proposed method is tested on a prototype hardware platform of 10- and 5-kW parallel rectifiers. Experiment results demonstrate the superiority of this method over existing methods under several typical scenarios.
引用
收藏
页码:3937 / 3948
页数:12
相关论文
共 24 条
  • [21] A Simplified Optimal Switching Sequence Model Predictive Control Without Weighting Coefficients for T-Type Single-Phase Three-Level Inverters
    Chen, Shengwei
    Yang, Yong
    Fan, Mingdi
    Chen, Rong
    Xiao, Yang
    Wen, Huiqing
    Wu, Weimin
    Hu, Jiefeng
    Zhang, Xinan
    Rodriguez, Jose
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (03): : 5936 - 5946
  • [22] Model Predictive Control without Weighting Factors for T-type Multilevel Inverters with Magnetic-Link and Series Stacked AC-DC Modules
    Khan, Shakil Ahamed
    Guo, Youguang
    Khan, Md Noman Habib
    Siwakoti, Yam
    Zhu, Jianguo
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 5603 - 5609
  • [23] Stability analysis and duty cycle limitation of grid-connected current control strategy for multiple parallel three-level T-type grid-connected inverters
    Liu, Jiang
    Sun, Xiangdong
    Ren, Biying
    Zhang, Qi
    IET POWER ELECTRONICS, 2020, 13 (18) : 4348 - 4358
  • [24] Fast Finite-Switching-State Model Predictive Control Method Without Weighting Factors for T-Type Three-Level Three-Phase Inverters
    Yang, Yong
    Wen, Huiqing
    Fan, Mingdi
    Xie, Menxi
    Chen, Rong
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (03) : 1298 - 1310