Influence of Humidity and Salinity on the Discharge Characteristics of a Short Rod-Plane Gap Under Negative DC Voltage

被引:6
作者
Meng, Xiangrui [1 ]
Shen, Nanxuan [1 ]
Lu, Tiebing [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewable, Beijing 102206, Peoples R China
关键词
Humidity; Discharges (electric); Corona; Electrodes; Voltage measurement; Partial discharges; Photomultipliers; negative corona discharge; partial discharge; rod-plane gap; salinity; CORONA INCEPTION VOLTAGES; RELATIVE-HUMIDITY; AIR; PRESSURES; MECHANISM; GRIDS; MODEL;
D O I
10.1109/TDEI.2022.3232579
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, the effects of air humidity and salinity on the discharge characteristics of a short rod-plane gap under negative dc voltage are investigated experimentally. The discharge of the rod-plane gap was recorded using a measuring resistance, photomultiplier tube, and ultraviolet imager. The experimental results show that corona discharge of rod electrode can be observed in the rod-plane gap when the relative humidity is lower than 70%, and furthermore, partial discharge of water molecules in the air can also be observed in the rod-plane gap when the relative humidity is higher than 70%. The partial discharge inception voltage (PDIV) decreases with the increase of air humidity and salinity, and the corona discharge inception voltage (CDIV) increases slightly with the increase of humidity. The average discharge current increases with the increase of applied voltage and humidity. The repetition rate of the optical pulse and the Trichel pulse increases with the increase of applied voltage. The discharge repetition rate of water molecules in the air can be estimated from the repetition rate difference between the optical pulse and the Trichel pulse. The amplitude of the Trichel pulse in clean air is higher than that in the salty air, while the repetition rate of the Trichel pulse in clean air is lower than that in the salty air, which is due to the charging of NaCl particles during discharge.
引用
收藏
页码:700 / 708
页数:9
相关论文
共 31 条
[1]   POSITIVE WIRE-TO-PLANE CORONAS AS INFLUENCED BY ATMOSPHERIC HUMIDITY [J].
ABDELSALAM, M .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1985, 21 (01) :35-40
[2]   Effect of relative humidity on current-voltage characteristics of monopolar DC wire-to-plane system [J].
Aissou, Massinissa ;
Said, Hakim Ait ;
Nouri, Hamou ;
Zebboudj, Youcef .
JOURNAL OF ELECTROSTATICS, 2015, 76 :108-114
[3]   Transmission design and analysis for large-scale offshore wind energy development [J].
Apostolaki-Iosifidou, Elpiniki ;
McCormack, Regina ;
Kempton, Willett ;
McCoy, Paul ;
Ozkan, Deniz .
IEEE Power and Energy Technology Systems Journal, 2019, 6 (01) :22-31
[4]   Effects of humidity on variation of negative corona-generated space charge in rod to plane electrode [J].
Bian, Xingming ;
He, Zichen ;
Zhu, JunYu ;
Pi, Xinan ;
Wan, Shuwei ;
Qi, Lei .
JOURNAL OF ENGINEERING-JOE, 2019, (16) :2869-2872
[5]   Negative Corona Inception Voltages in Rod-plane Gaps at Various Air Pressures and Humidities [J].
Bian, Xingming ;
Meng, Xiaobo ;
Wang, Liming ;
MacAlpine, J. M. K. ;
Guan, Zhicheng ;
Hui, Jianfeng .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (02) :613-619
[6]   Positive Corona Inception Voltages and Corona Currents for Air at Various Pressures and Humidities [J].
Bian, Xingming ;
Wang, Liming ;
MacAlpine, J. M. K. ;
Guan, Zhicheng ;
Hui, Jianfeng ;
Chen, Yong .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) :63-70
[7]   POSITIVE DC CORONA AND SPARKOVER IN SHORT AND LONG ROD-PLANE GAPS UNDER VARIABLE HUMIDITY CONDITIONS [J].
BOUTLENDJ, M ;
ALLEN, NL ;
LIGHTFOOT, HA ;
NEVILLE, RB .
IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1991, 138 (01) :31-36
[8]   On the Dynamic Modeling of Marine VSC-HVDC Power Grids Including Offshore Wind Farms [J].
Castro, Luis M. ;
Acha, Enrique .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2020, 11 (04) :2889-2900
[9]   Optical Emission Spectroscopy of Lightning Impulse Discharges in Long Air Gaps with and without Water Mist [J].
Chen, Bao-Hui ;
Deng, Jie ;
Pan, Bicheng ;
Liu, Yu ;
Zhou, Tiannian .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (04) :1110-1117
[10]  
Deng H, 1995, IEEE 1995 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, P145