Estimation of measurement uncertainty for the quantification of protein by ID-LC-MS/MS

被引:5
|
作者
Beasley-Green, Ashley [1 ]
Heckert, N. Alan [2 ]
机构
[1] Natl Inst Stand & Technol, Biomol Measurement Div, Mat Measurement Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Stat Engn Div, Informat Technol Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA
关键词
Measurement uncertainty; Isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS; MS); Albumin; Design of experiments (DOE); Reference measurement procedure (RMP); Standard Reference Material (R) (SRM);
D O I
10.1007/s00216-023-04705-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The emergence of mass spectrometry (MS)-based methods to quantify proteins for clinical applications has led to the need for accurate and consistent measurements. To meet the clinical needs of MS-based protein results, it is important that the results are traceable to higher-order standards and methods and have defined uncertainty values. Therefore, we outline a comprehensive approach for the estimation of measurement uncertainty of a MS-based procedure for the quantification of a protein biomarker. Using a bottom-up approach, which is the model outlined in the "Guide to the Expression of Uncertainty of Measurement" (GUM), we evaluated the uncertainty components of a MS-based measurement procedure for a protein biomarker in a complex matrix. The cause-and-effect diagram of the procedure is used to identify each uncertainty component, and statistical equations are derived to determine the overall combined uncertainty. Evaluation of the uncertainty components not only enables the calculation of the measurement uncertainty but can also be used to determine if the procedure needs improvement. To demonstrate the use of the bottom-up approach, the overall combined uncertainty is estimated for the National Institute of Standards and Technology (NIST) candidate reference measurement procedure for albumin in human urine. The results of the uncertainty approach are applied to the determination of uncertainty for the certified value for albumin in candidate NIST Standard Reference Material (R) (SRM) 3666. This study provides a framework for measurement uncertainty estimation of a MS-based protein procedure by identifying the uncertainty components of the procedure to derive the overall combined uncertainty.
引用
收藏
页码:3265 / 3274
页数:10
相关论文
共 50 条
  • [21] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of primidone in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Fischer, Vanessa
    Kobel, Anja
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1327 - 1338
  • [22] Determination of 72 Chemical Pesticides and Estimation of Measurement of Uncertainty in Rice Using LC-MS/MS and GC-MS/MS
    R Harischandra Naik
    M S Pallavi
    K Pavan Kumar
    B.K Vanitha
    V Chandra Sekhara Reddy
    A Shwetha
    Nandini S
    Naveenkumar P
    R Udaykumar Nidoni
    M Bheemanna
    Food Analytical Methods, 2021, 14 : 1788 - 1805
  • [23] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma
    Engel, Anett
    Ruhe, Lena
    Singh, Neeraj
    Wright, Jo Anne
    Liesch, Franziska
    Bauland, Friederike
    Ostermann, Annika I. I.
    Sumalowitsch, Tamara
    Schweinsberg, Vincent J. T.
    Geistanger, Andrea
    Hegel, Johannes Kolja
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1917 - 1929
  • [24] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of aldosterone in human serum and plasma
    Taibon, Judith
    Santner, Tobias
    Singh, Neeraj
    Ibrahim, Sara Cheikh
    Babitzki, Galina
    Koeppl, Daniel
    Gaudl, Alexander
    Geistanger, Andrea
    Ceglarek, Uta
    Rauh, Manfred
    Geletneky, Christian
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1902 - 1916
  • [25] Determination of 72 Chemical Pesticides and Estimation of Measurement of Uncertainty in Rice Using LC-MS/MS and GC-MS/MS
    Harischandra Naik, R.
    Pallavi, M. S.
    Pavan Kumar, K.
    Vanitha, B. K.
    Chandra Sekhara Reddy, V
    Shwetha, A.
    Nandini, S.
    Naveenkumar, P.
    Udaykumar Nidoni, R.
    Bheemanna, M.
    FOOD ANALYTICAL METHODS, 2021, 14 (09) : 1788 - 1805
  • [26] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Schierscher, Tobias
    Bachmann, Martina
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1930 - 1941
  • [27] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of phenobarbital in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Bachmann, Martina
    Kobel, Anja
    Wild, Janik
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1314 - 1326
  • [28] Various calibration procedures result in optimal standardization of routinely used 25(OH)D ID-LC-MS/MS methods
    Dirks, Niek F.
    Vesper, Hubert W.
    van Herwaarden, Antonius E.
    van den Ouweland, Jody M. W.
    Kema, Ido P.
    Krabbe, Johannes G.
    Heijboer, Annemieke C.
    CLINICA CHIMICA ACTA, 2016, 462 : 49 - 54
  • [29] LC-MS/MS for protein and peptide quantification in clinical chemistry
    Rauh, Manfred
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 883 : 59 - 67
  • [30] Development of matrix-based reference materials for 17 beta-estradiol by the recommended reference method of ID-LC-MS/MS
    Lin, Haibiao
    Liu, Dan
    Deng, Li
    Yan, Jun
    Han, Liqiao
    Zhan, Min
    Zhang, Pengwei
    Wang, Jianbing
    He, Min
    Zhang, Qiaoxuan
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (23) : 5637 - 5644