Estimation of measurement uncertainty for the quantification of protein by ID-LC-MS/MS

被引:5
|
作者
Beasley-Green, Ashley [1 ]
Heckert, N. Alan [2 ]
机构
[1] Natl Inst Stand & Technol, Biomol Measurement Div, Mat Measurement Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Stat Engn Div, Informat Technol Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA
关键词
Measurement uncertainty; Isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS; MS); Albumin; Design of experiments (DOE); Reference measurement procedure (RMP); Standard Reference Material (R) (SRM);
D O I
10.1007/s00216-023-04705-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The emergence of mass spectrometry (MS)-based methods to quantify proteins for clinical applications has led to the need for accurate and consistent measurements. To meet the clinical needs of MS-based protein results, it is important that the results are traceable to higher-order standards and methods and have defined uncertainty values. Therefore, we outline a comprehensive approach for the estimation of measurement uncertainty of a MS-based procedure for the quantification of a protein biomarker. Using a bottom-up approach, which is the model outlined in the "Guide to the Expression of Uncertainty of Measurement" (GUM), we evaluated the uncertainty components of a MS-based measurement procedure for a protein biomarker in a complex matrix. The cause-and-effect diagram of the procedure is used to identify each uncertainty component, and statistical equations are derived to determine the overall combined uncertainty. Evaluation of the uncertainty components not only enables the calculation of the measurement uncertainty but can also be used to determine if the procedure needs improvement. To demonstrate the use of the bottom-up approach, the overall combined uncertainty is estimated for the National Institute of Standards and Technology (NIST) candidate reference measurement procedure for albumin in human urine. The results of the uncertainty approach are applied to the determination of uncertainty for the certified value for albumin in candidate NIST Standard Reference Material (R) (SRM) 3666. This study provides a framework for measurement uncertainty estimation of a MS-based protein procedure by identifying the uncertainty components of the procedure to derive the overall combined uncertainty.
引用
收藏
页码:3265 / 3274
页数:10
相关论文
共 50 条
  • [1] Estimation of measurement uncertainty for the quantification of protein by ID-LC–MS/MS
    Ashley Beasley-Green
    N. Alan Heckert
    Analytical and Bioanalytical Chemistry, 2023, 415 : 3265 - 3274
  • [2] Determination of sulfonamides in milk by ID-LC-MS/MS
    Unsal, Isin Aydin
    Tasan, Murat
    Gokcen, Taner
    Goren, Ahmet C.
    JOURNAL OF CHEMICAL METROLOGY, 2018, 12 (01): : 70 - 78
  • [3] Development of a candidate reference measurement procedure by ID-LC-MS/MS for total tau protein measurement in cerebrospinal fluid (CSF)
    Giangrande, Chiara
    Vaneeckhoutte, Helene
    Boeuf, Amandine
    Lalere, Beatrice
    Hirtz, Christophe
    Lehmann, Sylvain
    Quaglia, Milena
    Delatour, Vincent
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (07) : 1235 - 1244
  • [4] Quantification of 25OHD in serum by ID-LC-MS/MS based on oriented immobilization of antibody on magnetic materials
    Keke Yi
    Jie Xie
    Ziyu Qu
    Yanling Lin
    Zejian Huang
    Tao Peng
    Yang Zhao
    Rui Zhai
    Xiaoyun Gong
    You Jiang
    Xinhua Dai
    Xiang Fang
    Microchimica Acta, 2023, 190
  • [5] Comparative evaluation of peptide vs. protein-based calibration for quantification of cardiac troponin I using ID-LC-MS/MS
    Asicioglu, Meltem
    Swart, Claudia
    Saban, Evren
    Yurek, Emrah
    Karaguler, Nevin Gul
    Oztug, Merve
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
  • [6] Quantification of 25OHD in serum by ID-LC-MS/MS based on oriented immobilization of antibody on magnetic materials
    Yi, Keke
    Xie, Jie
    Qu, Ziyu
    Lin, Yanling
    Huang, Zejian
    Peng, Tao
    Zhao, Yang
    Zhai, Rui
    Gong, Xiaoyun
    Jiang, You
    Dai, Xinhua
    Fang, Xiang
    MICROCHIMICA ACTA, 2023, 190 (06)
  • [7] Establishment and clinical application of a candidate reference measurement procedure for quantification of urinary vanillylmandelic acid and homovanillic acid using ID-LC-MS/MS method
    Yu, Lintao
    Kang, Shiyue
    Cheng, Long
    Zhang, Qiaoxuan
    Ouyang, Fen
    Han, Liqiao
    Zhan, Min
    Liao, Dezheng
    Zhang, Pengwei
    Yan, Jun
    Huang, Xianzhang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 248
  • [8] Description and validation of an equilibrium dialysis ID-LC-MS/MS candidate reference measurement procedure for free thyroxine in human serum
    Jansen, Heleen I.
    van der Steen, Rob
    Brandt, Andre
    Olthaar, Andre J.
    Vesper, Hubert W.
    Shimizu, Eri
    Heijboer, Annemieke C.
    Van Uytfanghe, Katleen
    van Herwaarden, Antonius E.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (09) : 1605 - 1611
  • [9] Clinical application of an optimized reference measurement procedure for serum digoxin using bracketing calibration method by ID-LC-MS/MS
    Yan, Qiaofang
    Huang, Fei
    Wang, Chuyang
    Zhan, Min
    Zhang, Qiaoxuan
    Huang, Di
    Yan, Jun
    Lin, Haibiao
    Huang, Xianzhang
    Han, Liqiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (29) : 6909 - 6918
  • [10] Simultaneous determination of ergothioneine, selenoneine, and their methylated metabolites in human blood using ID-LC-MS/MS
    Achouba, Adel
    Dumas, Pierre
    Ayotte, Pierre
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (29-30) : 7259 - 7267