Development of a validated stability-indicating HPLC- DAD method for dasabuvir and the characterization of its degradation products using LC-QToF-MS/MS

被引:0
|
作者
Junkert, Allan Michael [1 ]
Marson, Breno Mauricio [1 ]
Fachi, Mariana Millan [1 ]
Vilhena, Raquel de Oliveira [1 ]
Boeger, Beatriz [1 ]
Pontarolo, Roberto [1 ,2 ]
机构
[1] Univ Fed Parana, Dept Pharm, Pharmaceut Sci Postgrad Res Program, Curitiba, PR, Brazil
[2] Univ Fed Parana, Dept Farm, Jardim Bot, Campus 3,Ave Pref Lothario Meissner 632, BR-80210170 Curitiba, PR, Brazil
关键词
Dasabuvir; Degradation products; Liquid chromatography; Stability study; OMBITASVIR; DRUGS; ASSAY;
D O I
10.1590/s2175-97902023e21480
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A stability-indicating HPLC-DAD method was developed and validated for the simultaneous determination of dasabuvir and its degradation products in the pharmaceutical formulation. The proposed method utilized a Symmetry (R) C18 (4.6 x 75 mm, 3.5 gm) column, and the mobile phase consisted of an isocratic elution of formic acid (0.1%) and acetonitrile (55:45, v/v), at a flow of 1 mL min-1; analytes were detected at 244 nm. Dasabuvir was submitted to different stress degradation conditions, such as acidic, alkaline, neutral, thermal, oxidative and photolytic, and the structural elucidation of degradation products was performed using LC-QToF-MS/MS. The HPLC-DAD stability-indicating method was validated for selectivity, linearity, limit of detection and quantification, accuracy, precision and robustness, according to ICH guidelines. Dasabuvir produced two degradation products (DP1 and DP2) from the alkaline stress conditions, which were characterized in negative ion mode. Dasabuvir was linear in the range 9.78 to 136.92 gg mL-1, and DP1 and DP2 were linear in the range 2.9 to 20.2 gg mL-1 and 1.3 to 14.9 gg mL-1, respectively. The recovery ranged between 99.16 and 100.86%, while precision ranged from 1.02 to 2.89%. As the method can effectively separate the dasabuvir from its degradation products and quantitate them, it may be employed as a stability-indicating method for the pharmaceutical formulation.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A stability-indicating QTRAP LC-MS/MS method for identification and structural characterization of degradation products of indapamide
    Attia, Khalid A. M.
    Nassar, Mohamed W. I.
    El-Din, Mohie M. K. Sharaf
    Mohamad, Ahmad A. A.
    Kaddah, Mohamed M. Y.
    ANALYTICAL METHODS, 2016, 8 (08) : 1836 - 1851
  • [22] HPLC and LC-MS studies on stress degradation behaviour of tinidazole and development of a validated specific stability-indicating HPLC assay method
    Bakshi, M
    Singh, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 11 - 18
  • [23] A Validated Stability Indicating RP-HPLC Method for Nabumetone, Identification and Characterization of Forced Degradation Products of Nabumetone Using LC-MS/MS
    Sawant, Sanjay
    Barge, Vijaya
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (11) : 6203 - 6208
  • [24] A Validated Stability Indicating RP-HPLC Method for Valganciclovir, Identification and Characterization of Forced Degradation Products of Valganciclovir Using LC-MS/MS
    Sawant, S.
    Barge, V.
    ACTA CHROMATOGRAPHICA, 2014, 26 (01) : 29 - 42
  • [25] Stability-indicating HPLC method development and structural elucidation of novel degradation products in posaconazole injection by LC-TOF/MS, LC-MS/MS and NMR
    Yang, Yidi
    Zhu, Xi
    Zhang, Fei
    Li, Wei
    Wu, Ying
    Ding, Li
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 125 : 165 - 177
  • [26] Development and validation of stability-indicating method of etrasimod by HPLC/DAD/MS/MS technique with greenness profiling
    Kovacic, Jelena
    Klaric, Daniela Amidzic
    Turk, Niksa
    Krznaric, Zeljko
    Mornar, Ana
    HELIYON, 2024, 10 (13)
  • [27] Determination of lumiracoxib by a validated stability-indicating MEKC method and identification of its degradation products by LC-ESI-MS studies
    Sangoi, Maximiliano S.
    Wrasse-Sangoi, Micheli
    Oliveira, Paulo R.
    Bernardi, Larissa S.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1867 - 1874
  • [28] Development of stability-indicating HPLC method for quantification of pharmacopeia impurities of Zuclopenthixol and characterization of its stress degradation products by LCMS/MS
    Sesharamsingh, Bondili
    Kumar, J. Suresh
    Viswanath, I. V. Kasi
    Rao, Gattupalli Subhakara
    Anna, Venkateswara Rao
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 9 (01)
  • [29] Development of stability-indicating HPLC method for quantification of pharmacopeia impurities of Zuclopenthixol and characterization of its stress degradation products by LCMS/MS
    Bondili Sesharamsingh
    J. Suresh Kumar
    I. V. Kasi Viswanath
    Gattupalli Subhakara Rao
    Venkateswara Rao Anna
    Future Journal of Pharmaceutical Sciences, 9
  • [30] Development and validation of a stability-indicating, single HPLC method for sacubitril-valsartan and their stereoisomers and identification of forced degradation products using LC-MS/MS
    Vijaykumar, Cholleti
    Kumar, Yalavarti Ravindra
    Aparna, Pasula
    Rao, Pydimarry Surya Prakash
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (02)