Agreement of Oscillometric and Auscultatory blood pressure measurement methods: An ambulance noise simulation study

被引:2
|
作者
Tatliparmak, Ali Cankut [1 ]
Yilmaz, Sarper [2 ]
机构
[1] Kolan Int Hosp, Dept Emergency Med, Istanbul, Turkiye
[2] Univ Hlth Sci, Kartal Dr Lut fi Kirdar City Hosp, Dept Emergency Med, Istanbul, Turkiye
来源
关键词
Blood pressure measurement method; Oscillometric blood pressure measurement; Auscultatory blood pressure measurement; Ambulance noise;
D O I
10.1016/j.ajem.2023.02.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Although noise is known to negatively affect blood pressure (BP) measurements, its impact on different BP measurement methods remains unclear. The aim of this study is to compare the agreement of oscillometric and auscultatory BP measurement methods under in-ambulance noise levels. Methods: This method-comparison study was conducted on 50 healthy volunteers in a tertiary emergency department (ED). Participants were divided into two groups of 25, and BP was measured using auscultatory and oscillometric methods in noisy and ambient environments by 2 emergency medicine technicians (EMT). The primary object of the study was to compare the agreement of auscultatory mercury sphygmomanometers and automated auscillometric BP measurements in ambient and noisy environments. Results: We examined the agreement between auscultative and oscillometric measurements of BP conducted in an ambient environment (46.75 [IQR (41.2-55.18)] dB) and found that both systolic and diastolic BP were within the level of agreement (LoA) established before the study (systolic BP [-13.96 to 8.48 mmHG], diastolic BP [-7.44 to 8.08 mmHg]); whereas, in noisy environment (92.35 [IQR 88-96.55] dB) both systolic and diastolic BP were outside the range of LoA (systolic BP [-37.77 to 9.94 mmHg], diastolic BP [-21.73 to 16.37 mmHg]). Additionally, we found that in ambient environments, concordance correlation coefficients were higher than in noisy environments (0.943 [0.906-0.966], 0.957 [0.93-0.974]; 0.574 [0.419-0.697], 0.544 [0.326-0.707]; systolic and diastolic BP, respectively). Conclusion: The results of this study demonstrate that noise significantly affects the agreement between oscillometric and auscultatory blood pressure measurement methods. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 50 条
  • [21] Effect of Talking on Mean Arterial Blood Pressure: Agreement between Manual Auscultatory and Automatic Oscillometric Techniques
    Zheng, Dingchang
    Giovannini, Roberto
    Murray, Alan
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 841 - 844
  • [22] Errors of oscillometric blood pressure measurement as predicted by simulation
    Raamat, Rein
    Talts, Jaak
    Jagomaegi, Kersti
    Kivastik, Jana
    BLOOD PRESSURE MONITORING, 2011, 16 (05) : 238 - 245
  • [23] Effect of Cuff Design on Auscultatory and Oscillometric Blood Pressure Measurements
    Ringrose, Jennifer S.
    McLean, Donna
    Ao, Peter
    Yousefi, Farahnaz
    Sankaralingam, Sowndramalingam
    Millay, Jack
    Padwal, Raj
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (09) : 1063 - 1069
  • [24] A New Noise Reduction Method for Oscillometric Blood Pressure Measurement
    Choi, Hyun-Seok
    Myoung, Hyoun-Seok
    Lee, Hyo-Ki
    Park, Ho-Dong
    Lee, Kyoung-Joung
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 270 - +
  • [25] IMPACT OF USING INAPPROPRIATE CUFF SIZE IN BLOOD PRESSURE CLASSIFICATION: ANALYSIS FOR AUSCULTATORY AND OSCILLOMETRIC METHODS
    Albuquerque, Nila
    Sheppard, James
    Araujo, Thelma
    JOURNAL OF HYPERTENSION, 2021, 39 : E129 - E130
  • [26] Accuracy of oscillometric blood pressure monitoring with concurrent auscultatory blood pressure in hemodialysis patients
    Semret, M
    Zidehsarai, M
    Agarwal, R
    BLOOD PRESSURE MONITORING, 2005, 10 (05) : 249 - 255
  • [27] Ambient noise interferes with auscultatory blood pressure measurement during exercise
    Lightfoot, JT
    Tuller, B
    Williams, DF
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (04): : 502 - 508
  • [28] Can auscultatory blood pressure normative values be used for evaluation of oscillometric blood pressure in children?
    Sulakova, Terezie
    Sulakova, Astrida
    Strnadel, Jiri
    Pavlicek, Jan
    Obermannova, Barbora
    Feber, Janusz
    JOURNAL OF CLINICAL HYPERTENSION, 2017, 19 (04): : 381 - 387
  • [29] Instruments and Methods for Calibration of Oscillometric Blood Pressure Measurement Devices
    Balestrieri, Eulalia
    Rapuano, Sergio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (09) : 2391 - 2404
  • [30] Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia
    Natarajan, P
    Shennan, AH
    Penny, J
    Halligan, AW
    de Swiet, M
    Anthony, J
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1999, 181 (05) : 1203 - 1210