Agreement of Oscillometric and Auscultatory blood pressure measurement methods: An ambulance noise simulation study

被引:2
|
作者
Tatliparmak, Ali Cankut [1 ]
Yilmaz, Sarper [2 ]
机构
[1] Kolan Int Hosp, Dept Emergency Med, Istanbul, Turkiye
[2] Univ Hlth Sci, Kartal Dr Lut fi Kirdar City Hosp, Dept Emergency Med, Istanbul, Turkiye
来源
关键词
Blood pressure measurement method; Oscillometric blood pressure measurement; Auscultatory blood pressure measurement; Ambulance noise;
D O I
10.1016/j.ajem.2023.02.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Although noise is known to negatively affect blood pressure (BP) measurements, its impact on different BP measurement methods remains unclear. The aim of this study is to compare the agreement of oscillometric and auscultatory BP measurement methods under in-ambulance noise levels. Methods: This method-comparison study was conducted on 50 healthy volunteers in a tertiary emergency department (ED). Participants were divided into two groups of 25, and BP was measured using auscultatory and oscillometric methods in noisy and ambient environments by 2 emergency medicine technicians (EMT). The primary object of the study was to compare the agreement of auscultatory mercury sphygmomanometers and automated auscillometric BP measurements in ambient and noisy environments. Results: We examined the agreement between auscultative and oscillometric measurements of BP conducted in an ambient environment (46.75 [IQR (41.2-55.18)] dB) and found that both systolic and diastolic BP were within the level of agreement (LoA) established before the study (systolic BP [-13.96 to 8.48 mmHG], diastolic BP [-7.44 to 8.08 mmHg]); whereas, in noisy environment (92.35 [IQR 88-96.55] dB) both systolic and diastolic BP were outside the range of LoA (systolic BP [-37.77 to 9.94 mmHg], diastolic BP [-21.73 to 16.37 mmHg]). Additionally, we found that in ambient environments, concordance correlation coefficients were higher than in noisy environments (0.943 [0.906-0.966], 0.957 [0.93-0.974]; 0.574 [0.419-0.697], 0.544 [0.326-0.707]; systolic and diastolic BP, respectively). Conclusion: The results of this study demonstrate that noise significantly affects the agreement between oscillometric and auscultatory blood pressure measurement methods. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 50 条
  • [1] Blood pressure measurement by oscillometric and auscultatory methods in normotensive pregnant women
    Vigato, Estefanie Siqueira
    Tatagiba Lamas, Jose Luiz
    REVISTA BRASILEIRA DE ENFERMAGEM, 2019, 72 : 162 - 169
  • [2] Auscultatory versus oscillometric measurement of blood pressure in octogenarians
    Rosholm, Jens-Ulrik
    Arnspang, Sidsel
    Matzen, Lars
    Jacobsen, Ib A.
    BLOOD PRESSURE, 2012, 21 (05) : 269 - 272
  • [3] EFFECT OF UNDERCUFFING ON AUSCULTATORY AND OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT
    Albuquerque, Nila
    Padwal, Raj
    Araujo, Thelma
    JOURNAL OF HYPERTENSION, 2021, 39 : E130 - E130
  • [4] Comparison between oscillometric and auscultatory methods of ambulatory blood pressure measurement in hemodialysis patients
    Fagugli, RM
    Vecchi, L
    Valente, F
    Santirosi, P
    Laviola, MM
    CLINICAL NEPHROLOGY, 2002, 57 (04) : 283 - 288
  • [5] Comparing Intra-Arterial, Auscultatory, and Oscillometric Measurement Methods for Arterial Blood Pressure
    Babadag, Keziban
    Zaybak, Ayten
    FLORENCE NIGHTINGALE JOURNAL OF NURSING, 2021, 29 (02): : 194 - 202
  • [6] Comparability of oscillometric to simultaneous auscultatory blood pressure measurement in children
    Ringrose, Jennifer S.
    Alabbas, Abdullah
    Jalali, Afrooz
    Khinda, Harsimran
    Morgan, Catherine
    Yiu, Verna
    Alexander, R. Todd
    Padwal, Raj
    BLOOD PRESSURE MONITORING, 2019, 24 (02) : 83 - 88
  • [7] Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement
    Landgraf, Johanna
    Wishner, Stanley H.
    Kloner, Robert A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 386 - 388
  • [8] Oscillometric and auscultatory blood pressure measurement in the assessment of blood pressure and target organ damage
    Johansson, Jouni K.
    Puukka, Pauli J.
    Jula, Antti M.
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 6 - 13
  • [9] Oscillometric and auscultatory blood pressure measurement methods in children: a systematic review and meta-analysis
    Duncombe, Stephanie L.
    Voss, Christine
    Harris, Kevin C.
    JOURNAL OF HYPERTENSION, 2017, 35 (02) : 213 - 224
  • [10] Comparative study on auscultatory and oscillometric methods of ambulatory blood pressure measurements in adult patients
    Genc, Yasemin
    Altunkan, Sekip
    Kilinc, Oguzhan
    Altunkan, Erkan
    BLOOD PRESSURE MONITORING, 2008, 13 (01) : 29 - 35