Energetic, environmental and economic assessment of multi-evaporator CO2-NH3 cascade refrigeration system for seafood application

被引:11
|
作者
Saini, Santosh Kumar [1 ]
Dasgupta, Mani Sankar [1 ]
Widell, Kristina N. [2 ]
Bhattacharyya, Souvik [1 ]
机构
[1] BITS Pilani, Dept Mech Engn, Pilani 333031, Rajasthan, India
[2] SINTEF Ocean, N-7465 Trondheim, Norway
关键词
Cascade refrigeration; Natural refrigerants; Seafood; Environmental emission cost; Low GWP; LOW-GWP REFRIGERANTS; PERFORMANCE EVALUATION; EXERGY ANALYSIS; OPTIMIZATION; NH3/CO2; CO2;
D O I
10.1007/s10973-022-11619-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
Refrigeration plays a vital role in ensuring quality and safety of seafood. In a tropical country like India, the seafood industry has a relatively larger cooling load throughout the supply chain due to higher temperature differences between ambient and chilled seafood. The cooling demands in a seafood processing plant are typically at four different temperature levels. Supply of chilled water at 2 degrees C, ice at - 5 degrees C, cold storage maintained at - 25 degrees C, and a plate or blast freezer at - 40 degrees C. Commonly, a multi-evaporator multi-stage refrigeration system with refrigerants like R22, R404A, or NH3 are used in India. However, R22 and R404A have harmful effects on the environment due to their high global warming potential. This study proposed an all-natural multi-evaporator CO2-NH3 cascade refrigeration system (CRS). For comparison, the refrigeration demands in a surimi (seafood) processing and storage plant located in Mumbai were utilized. The study revealed that CO2-NH3 CRS has the highest COP and the lowest annual energy consumption followed by conventional NH3 system. CO2-NH3 CRS exhibited 6.2%, 12.3% and 3.2% less energy consumption compared to R22, R404A, and NH3 systems, respectively. Similarly, CO2-NH3 CRS also showed the lowest total equivalent warming impact which is 26.8%, 44.3% and 3.2% less compared to R22, R404A, and NH3 systems, respectively. Furthermore, CO2-NH3 CRS also presented relatively better results in terms of annual cost rate and life cycle cost.
引用
收藏
页码:2845 / 2856
页数:12
相关论文
共 50 条
  • [1] Energetic, environmental and economic assessment of multi-evaporator CO2–NH3 cascade refrigeration system for seafood application
    Santosh Kumar Saini
    Mani Sankar Dasgupta
    Kristina N. Widell
    Souvik Bhattacharyya
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 2845 - 2856
  • [2] Comparative analysis of a few novel multi-evaporator CO2-NH3 cascade refrigeration system for seafood processing & storage
    Saini, Santosh Kumar
    Dasgupta, Mani Sankar
    Widell, Kristina N.
    Bhattacharyya, Souvik
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 817 - 825
  • [3] Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures
    Dopazo, J. Alberto
    Fernandez-Seara, Jose
    Sieres, Jaime
    Uhia, Francisco J.
    APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) : 1577 - 1583
  • [4] Optimization of a liquid injection NH3/CO2 cascade refrigeration system. Energetic, exergetic and environmental assessment
    Hamzaoui, Malek
    Grine, Ali
    Tiachacht, Samir
    Beltagy, Hani
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2025, 196
  • [5] Thermodynamic Analysis and Comparison on Low Temperature CO2-NH3 Cascade Refrigeration Cycle
    查世彤
    马一太
    申江
    李敏霞
    Transactions of Tianjin University, 2003, (03) : 252 - 255
  • [6] Exergy assessment of a multistage multi-evaporator vapor compression refrigeration system using eighteen refrigerants
    Malwe, Prateek D.
    Shaikh, Juned
    Gawali, Bajirao S.
    ENERGY REPORTS, 2022, 8 : 153 - 162
  • [7] Exergetic, economic and environmental (3E) analyses, and multiobjective optimization of a CO2/NH3 cascade refrigeration system
    Aminyavari, Mehdi
    Najafi, Behzad
    Shirazi, Alec
    Rinaldi, Fabio
    APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) : 42 - 50
  • [8] Performance characteristics of multi-evaporator transcritical CO2 refrigeration cycles with hybrid compression/ejection
    Sarkar, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A6) : 773 - 780
  • [9] Energetic, Exergetic, Environmental, and Economic Assessment of a Cascade Refrigeration System Operating with Four Different Ecological Refrigerant Pairs
    de Paula, Cleison Henrique
    Duarte, Willian Moreira
    Rocha, Thiago Torres Martins
    de Oliveira, Raphael Nunes
    Maia, Antonio Augusto Torres
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (03)
  • [10] Exergy assessment on multi-evaporator cascade refrigeration system using R515B/R170 refrigerant pair: an experimental study
    Kasi, Parthiban
    Cheralathan, M.
    INTERNATIONAL JOURNAL OF EXERGY, 2024, 45 (3-4) : 159 - 174