Immunoassays: Analytical and Clinical Performance, Challenges, and Perspectives of SERS Detection in Comparison with Fluorescent Spectroscopic Detection

被引:11
作者
Terzapulo, Xeniya [1 ]
Kassenova, Aiym [1 ]
Bukasov, Rostislav [1 ]
机构
[1] Nazarbayev Univ, Dept Chem, Kabanbay Batyr Ave 53, Astana 010000, Kazakhstan
关键词
SERS; fluorescence; immunoassays; LOD; sensitivity; accuracy; non-specific binding; biomarker; cancer marker; ELISA; ENHANCED RAMAN-SCATTERING; LATERAL FLOW IMMUNOASSAY; HIGHLY SENSITIVE DETECTION; OF-CARE DETECTION; ULTRASENSITIVE DETECTION; QUANTUM DOTS; CARBON DOTS; SANDWICH IMMUNOASSAY; NANOPARTICLES; BIOMARKER;
D O I
10.3390/ijms25042080
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Immunoassays (IAs) with fluorescence-based detection are already well-established commercialized biosensing methods, such as enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay (LFIA). Immunoassays with surface-enhanced Raman spectroscopy (SERS) detection have received significant attention from the research community for at least two decades, but so far they still lack a wide clinical commercial application. This review, unlike any other review that we have seen, performs a three-dimensional performance comparison of SERS IAs vs. fluorescence IAs. First, we compared the limit of detection (LOD) as a key performance parameter for 30 fluorescence and 30 SERS-based immunoassays reported in the literature. We also compared the clinical performances of a smaller number of available reports for SERS vs. fluorescence immunoassays (FIAs). We found that the median and geometric average LODs are about 1.5-2 orders of magnitude lower for SERS-based immunoassays in comparison to fluorescence-based immunoassays. For instance, the median LOD for SERS IA is 4.3 x 10-13 M, whereas for FIA, it is 1.5 x 10-11 M. However, there is no significant difference in average relative standard deviation (RSD)-both are about 5-6%. The analysis of sensitivity, selectivity, and accuracy reported for a limited number of the published clinical studies with SERS IA and FIA demonstrates an advantage of SERS IA over FIA, at least in terms of the median value for all three of those parameters. We discussed common and specific challenges to the performances of both SERS IA and FIA, while proposing some solutions to mitigate those challenges for both techniques. These challenges include non-specific protein binding, non-specific interactions in the immunoassays, sometimes insufficient reproducibility, relatively long assay times, photobleaching, etc. Overall, this review may be useful for a large number of researchers who would like to use immunoassays, but particularly for those who would like to make improvements and move forward in both SERS-based IAs and fluorescence-based IAs.
引用
收藏
页数:33
相关论文
共 155 条
  • [11] Challenges in SERS-based pesticide detection and plausible solutions
    Bernat, Andrea
    Samiwala, Mustafa
    Albo, Jonathan
    Jiang, Xingyi
    Rao, Qinchun
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (45) : 12341 - 12347
  • [12] Digital SERS Protocol Using Au Nanoparticle-Based Extrinsic Raman Labels for the Determination of SARS-CoV-2 Spike Protein in Saliva Samples
    Bido, Ariadne Tuckmantel
    Brolo, Alexandre G.
    [J]. ACS APPLIED NANO MATERIALS, 2023, 6 (17) : 15426 - 15436
  • [13] An experimental and theoretical investigation of the thiophene/aluminum interface
    Blyth, RIR
    Mittendorfer, F
    Hafner, J
    Sardar, SA
    Duschek, R
    Netzer, FP
    Ramsey, MG
    [J]. JOURNAL OF CHEMICAL PHYSICS, 2001, 114 (02) : 935 - 942
  • [14] Immunoassays: their history, development and current place in food science and technology
    Bonwick, GA
    Smith, CJ
    [J]. INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2004, 39 (08) : 817 - 827
  • [15] Bose A., 2018, Int. J. Adv. Pharm. Res., V8, P1, DOI DOI 10.7439/IJAPA
  • [16] Alkaline phosphatase labeled SERS active sandwich immunoassay for detection of Escherichia coli
    Bozkurt, Akif Goktug
    Buyukgoz, Guluzar Gorkem
    Soforoglu, Mehmet
    Tamer, Ugur
    Suludere, Zekiye
    Boyaci, Ismail Hakki
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 194 : 8 - 13
  • [17] Aluminum Foil vs. Gold Film: Cost-Effective Substrate in Sandwich SERS Immunoassays of Biomarkers Reveals Potential for Selectivity Improvement
    Bukasov, Rostislav
    Sultangaziyev, Alisher
    Kunushpayeva, Zhanar
    Rapikov, Alisher
    Dossym, Dina
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (06)
  • [18] Surface-enhanced Raman scattering-based immunoassay for severe acute respiratory syndrome coronavirus 2
    Cha, Hyunjung
    Kim, Hyeran
    Joung, Younju
    Kang, Hyunju
    Moon, Jeong
    Jang, Hyowon
    Park, Sohyun
    Kwon, Hyung-Jun
    Lee, In-Chul
    Kim, Sunjoo
    Yong, Dongeun
    Yoon, Sun-Woo
    Park, Sung-Gyu
    Guk, Kyeonghye
    Lim, Eun-Kyung
    Park, Hyun Gyu
    Choo, Jaebum
    Jung, Juyeon
    Kang, Taejoon
    [J]. BIOSENSORS & BIOELECTRONICS, 2022, 202
  • [19] PSA Detection with Femtomolar Sensitivity and a Broad Dynamic Range Using SERS Nanoprobes and an Area-Scanning Method
    Chang, Hyejin
    Kang, Homan
    Ko, Eunbyeol
    Jun, Bong-Hyun
    Lee, Ho-Young
    Lee, Yoon-Sik
    Jeang, Dae Hong
    [J]. ACS SENSORS, 2016, 1 (06): : 645 - 649
  • [20] Fluorescence Immunoassay Based on the Phosphate-Triggered Fluorescence Turn-on Detection of Alkaline Phosphatase
    Chen, Chuanxia
    Zhao, Jiahui
    Lu, Yizhong
    Sun, Jian
    Yang, Xiurong
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (05) : 3505 - 3511