Differences in Kinematic Changes From Self-Selected to Fast Speed Gait in Asymptomatic Adults With Radiological Signs of Femoro-Acetabular Impingement

被引:1
作者
Yared, Fares [1 ]
Massaad, Abir [1 ]
Bakouny, Ziad [1 ]
Otayek, Joeffroy [1 ]
Bizdikian, Aren-Joe [1 ]
Ghanimeh, Joe [1 ]
Labaki, Chris [1 ]
Ghanem, Diane [1 ]
Ghanem, Ismat [1 ]
Skalli, Wafa [2 ]
Assi, Ayman [1 ]
机构
[1] St Joseph Univ Beirut, Lab Biomech & Med Imaging, Beirut, Lebanon
[2] ParisTech, Inst Biomecan Humaine Georges Charpak Arts & Metie, Paris, France
关键词
walking speed; kinematics; 3d reconstruction; gait; hip; femoro-acetabular impingement; COMPUTED-TOMOGRAPHY ANALYSIS; FEMOROACETABULAR IMPINGEMENT; LOWER-LIMB; HIP; OSTEOARTHRITIS; ANTEVERSION; PREVALENCE; PARAMETERS; MANAGEMENT; MORPHOLOGY;
D O I
10.7759/cureus.43733
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Femoro-acetabular impingement (FAI) may present as alterations in the skeletal morphology of the hip. Repercussions of FAI can be witnessed in self-selected speed walking as well as physical exercise such as running or fast speed walking. The aim of this study was to investigate changes in kinematics at different gait speeds in subjects presenting with radiological findings invoking FAI. One hundred thirty asymptomatic adults underwent biplanar X-rays with a calculation of 3D hip parameters: acetabular anteversion, abduction and tilt, vertical center edge angle (VCE), femoral anteversion, neck-shaft angle, acetabular coverage of the femoral head, femoral head diameter and neck length. Parameters were classified according to FAI clinical thresholds. Two groups were created: Control group (63 subjects having up to one subnormal hip parameter in favour of FAI) and Radiographic FAI group (67 subjects having >= 2 subnormal hip parameters that might cause FAI). All subjects underwent 3D gait analysis at self-selected and fast speed, from which kinematic parameters were generated. Arithmetic differences between fast and self-selected speed gait were considered as gait changes. Subjects in the Radiographic FAI group had decreased acetabular tilt (24 vs. 19 degrees), anteversion (19 vs. 16 degrees), abduction (55 vs. 53 degrees), femoral anteversion (18 vs. 14 degrees) and increased VCE (29 vs. 33 degrees, all p<0.05), compared to controls. Changes from self-selected to fast speed showed that subjects in the Radiographic FAI group had lower range of motion (ROM) pelvic rotation (7 vs. 4 degrees) and ROM hip flexion/extension (10 vs. 7 degrees), reduced hip extension (-4 vs. -2 degrees) and step length (16 vs. 13 cm; all p<0.05). The Radiographic FAI group had decreased acetabular abduction, anteversion and femoral anteversion in favour of FAI. When adapting from self-selected to fast speed gait, the Radiographic FAI group seemed to limit pelvic rotation and hip flexion/extension resulting in a decrease in step length. These kinematic limitations were previously reported in subjects with symptomatic FAI. Gait analysis could be considered as a functional diagnostic tool to assess FAI along with radiological assessment.
引用
收藏
页数:11
相关论文
共 43 条
  • [1] Gait and Lower Extremity Kinematic Analysis as an Outcome Measure After Femoroacetabular Impingement Surgery
    Alradwan, Hussain
    Khan, Moin
    Grassby, Maggie Hamel-Smith
    Bedi, Asheesh
    Philippon, Marc J.
    Ayeni, Olufemi R.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (02) : 339 - 344
  • [2] The effect of femoro-acetabular impingement on the kinematics and kinetics of the hip joint
    Alshameeri, Zeiad
    Khanduja, Vikas
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1615 - 1620
  • [3] Gait analysis in children and uncertainty assessment for Davis protocol and Gillette Gait Index
    Assi, Ayman
    Ghanem, Ismat
    Lavaste, Francois
    Skalli, Wafa
    [J]. GAIT & POSTURE, 2009, 30 (01) : 22 - 26
  • [4] Hip Morphological Characteristics and Range of Internal Rotation in Femoroacetabular Impingement
    Audenaert, Emmanuel A.
    Peeters, Ian
    Vigneron, Lara
    Baelde, Nick
    Pattyn, Christophe
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (06) : 1329 - 1336
  • [5] Hip morphology influences the pattern of damage to the acetabular cartilage - Femoroacetabular impingement as a cause of early osteoarthritis of the hip
    Beck, M
    Kalhor, M
    Leunig, M
    Ganz, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (07): : 1012 - 1018
  • [6] Healthy vs. osteoarthritic hips: A comparison of hip, pelvis and femoral parameters and relationships using the EOS® system
    Bendaya, S.
    Lazennec, J. Y.
    Anglin, C.
    Allena, R.
    Sellam, N.
    Thoumie, P.
    Skalli, W.
    [J]. CLINICAL BIOMECHANICS, 2015, 30 (02) : 195 - 204
  • [7] Data management in gait analysis for clinical applications
    Benedetti, MG
    Catani, F
    Leardini, A
    Pignotti, E
    Giannini, S
    [J]. CLINICAL BIOMECHANICS, 1998, 13 (03) : 204 - 215
  • [8] Femoroacetabular Impingement in Athletes Current Concepts
    Byrd, J. W. Thomas
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (03) : 737 - 751
  • [9] Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays
    Chaibi, Y.
    Cresson, T.
    Aubert, B.
    Hausselle, J.
    Neyret, P.
    Hauger, O.
    de Guise, J. A.
    Skalli, W.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) : 457 - 466
  • [10] A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE
    DAVIS, RB
    OUNPUU, S
    TYBURSKI, D
    GAGE, JR
    [J]. HUMAN MOVEMENT SCIENCE, 1991, 10 (05) : 575 - 587