Modified endurance time method for seismic performance assessment of base-isolated structures

被引:13
|
作者
Movahhed, Ataallah Sadeghi [1 ]
Shirkhani, Amir [2 ]
Zardari, Saeid [3 ]
Mashayekhi, Mohammadreza [4 ]
Farsangi, Ehsan Noroozinejad [5 ]
Majdi, Ali [6 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Shabestar Branch, Shabestar, Iran
[2] Univ Tabriz, Fac Civil Engn, Dept Struct Engn, Tabriz, Iran
[3] Istanbul Okan Univ, Dept Civil Engn, Istanbul, Turkiye
[4] K N Toosi Univ Technol, Dept Civil Engn, Tehran, Iran
[5] Grad Univ Adv Technol, Fac Civil & Surveying Engn, Kerman, Iran
[6] Al Mustaqbal Univ Coll, Dept Bldg & Construct Tech Engn, Hillah 51001, Babylon, Iraq
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 67卷
关键词
Endurance time method; Endurance time excitation functions; Nonlinear time history analysis; Base isolation system; Modified endurance time method; Seismic resilience; SLIDING ISOLATION BEARINGS; STRONG-MOTION DURATION; STEEL FRAMES; ADAPTIVE-BEHAVIOR; FRICTION; EXCITATIONS; DESIGN;
D O I
10.1016/j.jobe.2023.105955
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Endurance time (ET) method is a novel Time History Analysis (THA) approach in which structures are subjected to a set of intensifying excitations called endurance time excitation functions (ETEF). Although various studies show the efficiency of the ET method for the seismic evaluation of fixed base structures, this method has been less employed in isolated structures. The lack of coverage of high-intensity measures by existing ETEFs is the major obstacle to adopting the ET method in high-period structures such as isolated structures. It must be noted that high-intensity measures that are associated with large earthquakes are of paramount importance in performance assessment. This paper introduced a novel method called the modified endurance time (MET) method based on scaling existing ETEFs to alleviate this problem. By averaging multiple scaled ETEFs, the accuracy of the ET method is improved. Three steel structures with a different number of stories (6, 9, and 12), including Intermediate Moment Frames (IMFs), mounted on Triple Friction Pendulum Isolators (TFPIs) are considered to demonstrate the efficiency of the proposed method. These structures are analyzed under ETEFs with intensity multipliers 1 to 4 for three seismic hazard levels with return periods of 72, 475, and 2475 years. The effect of changing parameters such as isolator damping and period is also investigated on the results. The seismic responses obtained from the Endurance Time Analysis (ETA) are compared with the responses obtained from the nonlinear THA and pushover analysis. Results show that increasing the intensity multiplier of ETEFs can greatly improve the accuracy of results. However, it should be careful in the procedure of selecting the appropriate intensity multiplier. Because of the unbalanced changes in some ETEFs parameters such as PGV/PGA, the accuracy of results may also reduce by increasing the intensity multiplier. Therefore, the use of different combinations of results, obtained from several intensity multipliers, is investigated and proposed to reduce the error in results.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Dynamic behavior and seismic performance of base-isolated structures with electromagnetic inertial mass dampers: Analytical solutions and simulations
    Wang, Heng
    Shen, Wenai
    Li, Yamin
    Zhu, Hongping
    Zhu, Songye
    ENGINEERING STRUCTURES, 2021, 246
  • [22] Seismic performance of advanced three-dimensional base-isolated nuclear structures in complex-layered sites
    Liu, Yu
    Li, Jianbo
    Lin, Gao
    ENGINEERING STRUCTURES, 2023, 289
  • [23] A methodology for value based seismic design of structures by the endurance time method
    Basim, M. Ch.
    Estekanchi, H. E.
    Vafai, A.
    SCIENTIA IRANICA, 2016, 23 (06) : 2514 - 2527
  • [24] Application of first-order reliability method in seismic loss assessment of structures with Endurance Time analysis
    Basim, Mohammad Ch.
    Estekanchi, Homayoon E.
    Mahsuli, Mojtaba
    EARTHQUAKES AND STRUCTURES, 2018, 14 (05) : 437 - 447
  • [25] A simple method for approximate estimation of the displacement response of base-isolated structures
    Yaghmaei-Sabegh, Saman
    Jafari, Ebrahim
    Neekmanesh, Shabnam
    STRUCTURES, 2022, 41 : 1570 - 1583
  • [26] Sliding implant-magnetic bearing for adaptive seismic mitigation of base-isolated structures
    Peng, Yongbo
    Huang, Tianchen
    STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (10)
  • [27] A simulation-based framework for risk assessment and probabilistic sensitivity analysis of base-isolated structures
    Taflanidis, Alexandros A.
    Jia, Gaofeng
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (14) : 1629 - 1651
  • [28] Seismic performance evaluation of reinforced concrete frame structures using the endurance time method
    Bai J.-L.
    Ou J.-P.
    Ou, Jin-Ping (oujinping@hit.edu.cn), 1600, Tsinghua University (33): : 86 - 96
  • [29] Seismic resilience assessment of base-isolated structures with friction pendulum isolation bearings based on two-dimensional fragility
    He, Puchang
    Ma, Ying
    Liu, Chengqing
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [30] Seismic assessment of concrete frames by endurance time method
    Amouzegar, Hamed
    Riahi, Hossein Tajmir
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2015, 168 (08) : 578 - 592