Modified endurance time method for seismic performance assessment of base-isolated structures

被引:13
|
作者
Movahhed, Ataallah Sadeghi [1 ]
Shirkhani, Amir [2 ]
Zardari, Saeid [3 ]
Mashayekhi, Mohammadreza [4 ]
Farsangi, Ehsan Noroozinejad [5 ]
Majdi, Ali [6 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Shabestar Branch, Shabestar, Iran
[2] Univ Tabriz, Fac Civil Engn, Dept Struct Engn, Tabriz, Iran
[3] Istanbul Okan Univ, Dept Civil Engn, Istanbul, Turkiye
[4] K N Toosi Univ Technol, Dept Civil Engn, Tehran, Iran
[5] Grad Univ Adv Technol, Fac Civil & Surveying Engn, Kerman, Iran
[6] Al Mustaqbal Univ Coll, Dept Bldg & Construct Tech Engn, Hillah 51001, Babylon, Iraq
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 67卷
关键词
Endurance time method; Endurance time excitation functions; Nonlinear time history analysis; Base isolation system; Modified endurance time method; Seismic resilience; SLIDING ISOLATION BEARINGS; STRONG-MOTION DURATION; STEEL FRAMES; ADAPTIVE-BEHAVIOR; FRICTION; EXCITATIONS; DESIGN;
D O I
10.1016/j.jobe.2023.105955
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Endurance time (ET) method is a novel Time History Analysis (THA) approach in which structures are subjected to a set of intensifying excitations called endurance time excitation functions (ETEF). Although various studies show the efficiency of the ET method for the seismic evaluation of fixed base structures, this method has been less employed in isolated structures. The lack of coverage of high-intensity measures by existing ETEFs is the major obstacle to adopting the ET method in high-period structures such as isolated structures. It must be noted that high-intensity measures that are associated with large earthquakes are of paramount importance in performance assessment. This paper introduced a novel method called the modified endurance time (MET) method based on scaling existing ETEFs to alleviate this problem. By averaging multiple scaled ETEFs, the accuracy of the ET method is improved. Three steel structures with a different number of stories (6, 9, and 12), including Intermediate Moment Frames (IMFs), mounted on Triple Friction Pendulum Isolators (TFPIs) are considered to demonstrate the efficiency of the proposed method. These structures are analyzed under ETEFs with intensity multipliers 1 to 4 for three seismic hazard levels with return periods of 72, 475, and 2475 years. The effect of changing parameters such as isolator damping and period is also investigated on the results. The seismic responses obtained from the Endurance Time Analysis (ETA) are compared with the responses obtained from the nonlinear THA and pushover analysis. Results show that increasing the intensity multiplier of ETEFs can greatly improve the accuracy of results. However, it should be careful in the procedure of selecting the appropriate intensity multiplier. Because of the unbalanced changes in some ETEFs parameters such as PGV/PGA, the accuracy of results may also reduce by increasing the intensity multiplier. Therefore, the use of different combinations of results, obtained from several intensity multipliers, is investigated and proposed to reduce the error in results.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Application of the Modified Endurance Time Method for Predicting Seismic Response of Base-Isolated Structures Under Pounding
    Majdi, Ali
    Sadeghi-Movahhed, Ataallah
    Farsangi, Ehsan Noroozinejad
    Mashayekhi, Mohammadreza
    Almujibah, Hamad
    De Domenico, Dario
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2025,
  • [2] Seismic performance assessment of fixed offshore structures by endurance time method
    Diznab, Mohammad Ali Dastan
    Mehdigholi, Hamid
    Seif, Mohammad Saeed
    SHIPS AND OFFSHORE STRUCTURES, 2019, 14 (07) : 709 - 722
  • [3] Design and assessment of seismic resilient structures by the endurance time method
    Estekanchi, H. E.
    Vafai, A.
    Basim, M. Ch.
    SCIENTIA IRANICA, 2016, 23 (04) : 1648 - 1657
  • [4] Seismic behavior of torsionally coupled base-isolated structures
    Fallahian, Milad
    Paytam, Farzane
    Khoshnoudian, Faramarz
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2016, 169 (03) : 159 - 173
  • [5] Seismic performance of a building base-isolated by TFP to with a moat wall
    Movahhed, Ataallah Sadeghi
    Zardari, Saeid
    Sadoglu, Erol
    EARTHQUAKES AND STRUCTURES, 2022, 23 (01) : 87 - 100
  • [6] Seismic reliability assessment of base-isolated bridges in Quebec
    Nassar, M.
    Guizani, L.
    Nollet, M-J
    Tahan, A.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2022, 49 (02) : 242 - 254
  • [7] Application of Endurance Time Method for the Seismic Assessment of an Isolated Viaduct
    Nemati, Hamidreza
    Poursadrollah, Arash
    Katebi, Javad
    D Aniello, Mario
    Landolfo, Raffaele
    Bahar, Arash
    INGEGNERIA SISMICA, 2021, 38 (01): : 66 - 87
  • [8] Seismic Performance Comparison of Fixed and Base-Isolated Models
    Ozer, Esra
    Inel, Mehmet
    Cayci, Bayram Tanik
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2023, 47 (02) : 1007 - 1023
  • [9] Value based seismic design of structures using performance assessment by the endurance time method
    Mirfarhadi, S. Ali
    Estekanchi, Homayoon E.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2020, 16 (10) : 1397 - 1415
  • [10] Seismic reliability assessment of base-isolated structures using artificial neural network: operation failure of sensitive equipment
    Moeindarbari, Hesamaldin
    Taghikhany, Touraj
    EARTHQUAKES AND STRUCTURES, 2018, 14 (05) : 425 - 436