Intermittently stiffened cold-formed steel GFRP composite lightweight built-up beams: Experimental investigation and performance assessment

被引:10
|
作者
Dar, Mohammad Adil [1 ]
Subramanian, N.
Ghowsi, Ahmad Fayeq [2 ]
Anbarasu, M. [3 ]
Hajirasouliha, Iman [1 ]
Haris, Sheikh [4 ]
Dar, A. R. [4 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield, England
[2] Istanbul Tech Univ, Fac Architecture, Struct & Earthquake Engn Div, Istanbul, Turkiye
[3] Govt Coll Engn Salem, Dept Civil Engn, Salem, Tamil Nadu, India
[4] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar, J&k, India
关键词
Cold -formed steel; Built-up section; Strength; Stiffness; GFRP; Experiments; FLEXURAL BEHAVIOR; MOMENT CAPACITY; SECTIONS; STRENGTH; DESIGN; WEB;
D O I
10.1016/j.tws.2023.110630
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Previous attempts to develop lightweight cold-formed steel (CFS) composite sections have successfully improved their buckling strengths but have been limited to unstiffened profiles only. This paper reports the results of an experimental program on the flexural behavior of newly developed CFSGFRP (Glass Fiber Reinforced Plastic) composite built-up open-section beams. In total, six large-scale specimens were tested under four-point loading with simply supported boundary conditions. To counter the inherent limitation of premature local buckling in the thin-walled CFS sections under compressive stresses, various combinations of intermittent stiffening and GFRP plank packing were adopted to improve the performance of the CFS GFRP lightweight composite beam specimens. The intermittent stiffening and GFRP plank packing were used judiciously in the compression flange and the web region of the specimens. A conventional open-section built-up beam was fabricated using two plain channels fastened through the web as a benchmark to evaluate the flexural performance of the composite beams. Furthermore, a hot-rolled steel beam with equivalent dimensions was also tested to give a broader comparison. The flexural performance of all the beams was assessed in terms of peak strength, initial stiffness, load-deformation response, failure modes and strength-to-weight parameter. The results confirmed the structural feasibility of adopting GFRP to form CFS lightweight built-up beams. The incorporation of GFRP planks significantly improved the flexural capacity by about 180% compared to the conventional CFS built-up beams. They also helped in attaining about 80% of the equivalent hot-rolled steel beam's flexural strength, resulting in highly efficient built-up beams for practical applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Flexural Strength of cold-formed steel built-up composite beams with rectangular compression flanges
    Dar, M. Adil
    Subramanian, N.
    Dar, Dawood A.
    Dar, A. R.
    Anbarasu, M.
    Lim, James B. P.
    Mahjoubi, Soroush
    STEEL AND COMPOSITE STRUCTURES, 2020, 34 (02) : 171 - 188
  • [32] Nonlinear Study on the Mechanical Performance of Built-Up Cold-Formed Steel Concrete-Filled Columns under Compression
    Harrat, Oulfa
    Hadidane, Yazid
    Anas, S. M.
    Sor, Nadhim Hamah
    Deifalla, Ahmed Farouk
    Awoyera, Paul O.
    Gouider, Nadia
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2024, 139 (03): : 3435 - 3465
  • [33] Numerical modelling of cold-formed steel built-up columns
    Meza, Francisco J.
    Becque, Jurgen
    THIN-WALLED STRUCTURES, 2023, 188
  • [34] Experimental Investigation of the Deformation of Built-up Members of Cold-formed Steel Profiles
    Georgieva, Iveta
    Schueremans, Luc
    De Roeck, Guido
    Pyl, Lincy
    ADVANCES IN EXPERIMENTAL MECHANICS VIII, 2011, 70 : 416 - +
  • [35] Post-fire flexural behaviour and performance of unrestrained cold-formed steel built-up section beams: Experimental and numerical investigation
    Kumar, G. Jaya
    Kiran, T.
    Anand, N.
    Anbarasu, M.
    Lubloy, Eva
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 18
  • [36] Bending Moment Capacity of Cold-Formed Steel Built-Up Beams
    Mohamed Ghannam
    International Journal of Steel Structures, 2019, 19 : 660 - 671
  • [37] Experimental study on the composite action in sheathed and bare built-up cold-formed steel columns
    Fratamico, David C.
    Torabian, Shahabeddin
    Zhao, Xi
    Rasmussen, Kim J. R.
    Schafer, Benjamin W.
    THIN-WALLED STRUCTURES, 2018, 127 : 290 - 305
  • [38] Nonlinear behaviour of built-up cold-formed steel section battened columns
    Dabaon, Mohamed
    Ellobody, Ehab
    Ramzy, Khaled
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 : 16 - 28
  • [39] Experimental investigation of cold-formed stainless steel built-up closed section stub columns
    Li, Hai -Ting
    Jin, Chun -Chi
    Li, Qiu-Yun
    Young, Ben
    ENGINEERING STRUCTURES, 2024, 306
  • [40] Experimental investigation of cold-formed steel built-up closed section columns with web stiffeners
    Zhang, Jia-Hui
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 147 : 380 - 392