Intermittently stiffened cold-formed steel GFRP composite lightweight built-up beams: Experimental investigation and performance assessment

被引:10
|
作者
Dar, Mohammad Adil [1 ]
Subramanian, N.
Ghowsi, Ahmad Fayeq [2 ]
Anbarasu, M. [3 ]
Hajirasouliha, Iman [1 ]
Haris, Sheikh [4 ]
Dar, A. R. [4 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield, England
[2] Istanbul Tech Univ, Fac Architecture, Struct & Earthquake Engn Div, Istanbul, Turkiye
[3] Govt Coll Engn Salem, Dept Civil Engn, Salem, Tamil Nadu, India
[4] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar, J&k, India
关键词
Cold -formed steel; Built-up section; Strength; Stiffness; GFRP; Experiments; FLEXURAL BEHAVIOR; MOMENT CAPACITY; SECTIONS; STRENGTH; DESIGN; WEB;
D O I
10.1016/j.tws.2023.110630
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Previous attempts to develop lightweight cold-formed steel (CFS) composite sections have successfully improved their buckling strengths but have been limited to unstiffened profiles only. This paper reports the results of an experimental program on the flexural behavior of newly developed CFSGFRP (Glass Fiber Reinforced Plastic) composite built-up open-section beams. In total, six large-scale specimens were tested under four-point loading with simply supported boundary conditions. To counter the inherent limitation of premature local buckling in the thin-walled CFS sections under compressive stresses, various combinations of intermittent stiffening and GFRP plank packing were adopted to improve the performance of the CFS GFRP lightweight composite beam specimens. The intermittent stiffening and GFRP plank packing were used judiciously in the compression flange and the web region of the specimens. A conventional open-section built-up beam was fabricated using two plain channels fastened through the web as a benchmark to evaluate the flexural performance of the composite beams. Furthermore, a hot-rolled steel beam with equivalent dimensions was also tested to give a broader comparison. The flexural performance of all the beams was assessed in terms of peak strength, initial stiffness, load-deformation response, failure modes and strength-to-weight parameter. The results confirmed the structural feasibility of adopting GFRP to form CFS lightweight built-up beams. The incorporation of GFRP planks significantly improved the flexural capacity by about 180% compared to the conventional CFS built-up beams. They also helped in attaining about 80% of the equivalent hot-rolled steel beam's flexural strength, resulting in highly efficient built-up beams for practical applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [11] Effect of GFRP strengthening on the flexural behaviour of cold-formed steel built-up beams
    A. R. Dar
    Innovative Infrastructure Solutions, 2022, 7
  • [12] Experimental Study of Cold-Formed Steel Built-Up Beams
    Meza, Francisco J.
    Becque, Jurgen
    Hajirasouliha, Iman
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (07)
  • [13] Experimental and Numerical Investigation on Flexural Behavior of Novel Unsymmetrical Cold-Formed Steel Built-Up Stiffened Box Sections
    Dai, Yecheng
    Raftery, Gary M.
    Roy, Krishanu
    Hajirasouliha, Iman
    Fang, Zhiyuan
    Chen, Boshan
    Lim, James B. P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2025, 151 (02)
  • [14] Flexural Integrity Between the Individual Channels of Built-Up Cold-Formed Steel Beams
    Suhaib, Mir Basar
    Tantray, Manzoor Ahmad
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2023, 23 (02) : 503 - 520
  • [15] Numerical investigation of the flexural-torsional behaviour of built-up cold-formed steel beams
    Ma, Di
    Rasmussen, Kim J. R.
    Zhang, Hao
    THIN-WALLED STRUCTURES, 2025, 212
  • [16] Sustainable Performance of a Modular Building System Made of Built-Up Cold-Formed Steel Beams
    Thirunavukkarasu, Kajaharan
    Kanthasamy, Elilarasi
    Gatheeshgar, Perampalam
    Poologanathan, Keerthan
    Rajanayagam, Heshachanaa
    Suntharalingam, Thadshajini
    Dissanayake, Madhushan
    BUILDINGS, 2021, 11 (10)
  • [17] Experimental investigation of built-up cold-formed steel section battened columns
    Dabaon, Mohamed
    Ellobody, Ehab
    Ramzy, Khaled
    THIN-WALLED STRUCTURES, 2015, 92 : 137 - 145
  • [18] The Evolution and Performance of Cold-Formed Steel Built-Up Battened Columns
    Jainudin, N. F.
    Jamaluddin, N.
    Jaini, Zainorizuan Mohd
    Hakim, S. J. s
    Mohamad, Noridah
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2024, 16 (05): : 444 - 453
  • [20] Bending response of cold-formed steel built-up beams with overlapped flanges in stiffened channels
    A. R. Dar
    Innovative Infrastructure Solutions, 2021, 6