Combining trapped ion mobility spectrometry with liquid chromatography and tandem mass spectrometry for analysis of isomeric PDE-5 inhibitor analogs

被引:2
|
作者
Falconer, Travis M. [1 ,4 ]
Schneider, Birgit [2 ]
Baessmann, Carsten [2 ]
Wendt, Karin [2 ]
Filipenko, Artem [3 ]
机构
[1] US FDA, Forens Chem Ctr, Off Regulatory Affairs, Off Regulatory Sci, Cincinnati, OH USA
[2] Bruker Dalton & Co KG, Solut Dev Appl Markets & Characterizat, Bremen, Germany
[3] Bruker Daltonics Inc, Billerica, MA USA
[4] US FDA, Forens Chem Ctr, 6751 Steger Dr, Cincinnati, OH 45237 USA
关键词
PDE-5; inhibitors; Ion mobility spectrometry; Liquid chromatography; Mass spectrometry; PHOSPHODIESTERASE-5; INHIBITORS; DIETARY-SUPPLEMENTS; STRUCTURAL-CHARACTERIZATION; ADULTERANTS; FUNDAMENTALS;
D O I
10.1016/j.jpba.2022.115210
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection and identification of phosphodiesterase type 5 enzyme (PDE-5) inhibitors in dietary supplements poses an analytical challenge due to the large number of analogs and isomers currently available and the continued introduction of novel analogs. The use of trapped ion mobility spectrometry (TIMS) in conjunction with liquid chromatography (LC) and electrospray ionization tandem mass spectrometry (MS/MS) was explored for the analysis of two groups of isomeric PDE-5 inhibitor analogs using a 5-minute method. Of the eight compounds studied, six were resolved by a combination of LC and TIMS; the two remaining isomers were distinguished by one or more unique product ions in the MS/MS spectrum. The results revealed that separation by LC corresponded to differences in substitution on the piperazine moiety of the PDE-5 inhibitors, while sep-aration by TIMS corresponded to the position of a nitrogen atom in the fused ring region of the molecules. Samples prepared by spiking mixtures of varying amounts of the Group 2 isomers into a representative dietary supplement matrix were analyzed and concentrations determined from the mobility-adjusted extracted ion chromatograms exhibited relative standard deviations of 6.0 % or less for 17 of 20 measurements and recoveries between 80 % and 120 % for all measurements. Quantitative measurements from a short LC gradient were possible due to the reduced chemical background associated with the TIMS separation of co-eluting matrix compounds, which enabled acquisition of rapid and qualitatively relevant broadband collision induced disso-ciation spectra that didn't require precursor ion isolation; the reduced chemical background permits non-targeted detection of novel analogs and eliminates the need for a separate method for quantitative measurement.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Recent advances in biological separations using trapped ion mobility spectrometry - mass spectrometry
    Fouque, Kevin Jeanne Dit
    Fernandez-Lima, Francisco
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 116 : 308 - 315
  • [22] Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry
    Kyle, Jennifer E.
    Zhang, Xing
    Weitz, Karl K.
    Monroe, Matthew E.
    Ibrahim, Yehia M.
    Moore, Ronald J.
    Cha, Jeeyeon
    Sun, Xiaofei
    Lovelace, Erica S.
    Wagoner, Jessica
    Polyak, Stephen J.
    Metz, Thomas O.
    Dey, Sudhansu K.
    Smith, Richard D.
    Burnum-Johnson, Kristin E.
    Baker, Erin S.
    ANALYST, 2016, 141 (05) : 1649 - 1659
  • [23] High-throughput liquid chromatography-vacuum differential mobility spectrometry-mass spectrometry for the analysis of isomeric drugs of abuse in human urine
    Girard, Maria Fernanda Cifuentes
    Knight, Patrick
    Hopfgartner, Gerard
    DRUG TESTING AND ANALYSIS, 2024,
  • [24] Critical Comparison of Liquid Chromatography Coupled to Mass Spectrometry and Three Different Ion Mobility Spectrometry Systems on Their Separation Capability for Small Isomeric Compounds
    Werres, Tobias
    Leonhardt, Juri
    Jaeger, Martin
    Teutenberg, Thorsten
    CHROMATOGRAPHIA, 2019, 82 (01) : 251 - 260
  • [25] Critical Comparison of Liquid Chromatography Coupled to Mass Spectrometry and Three Different Ion Mobility Spectrometry Systems on Their Separation Capability for Small Isomeric Compounds
    Tobias Werres
    Juri Leonhardt
    Martin Jäger
    Thorsten Teutenberg
    Chromatographia, 2019, 82 : 251 - 260
  • [26] Analysis of vitamin D metabolites by liquid chromatography-tandem mass spectrometry
    van den Ouweland, Johannes M. W.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 84 : 117 - 130
  • [27] Ion mobility spectrometry and mass spectrometry coupled to gas chromatography for analysis of microbial contaminated cosmetic creams
    Garcia-Nicolas, Maria
    Arroyo-Manzanares, Natalia
    de Dios Hernandez, Juan
    Guillen, Isidro
    Vizcaino, Pascuala
    Sanchez-Rubio, Marta
    Lopez-Garcia, Ignacio
    Hernandez-Cordoba, Manuel
    Vinas, Pilar
    ANALYTICA CHIMICA ACTA, 2020, 1128 : 52 - 61
  • [28] Comprehensive lipidomic analysis of human plasma using multidimensional liquid- and gas-phase separations: Two-dimensional liquid chromatography-mass spectrometry vs. liquid chromatography-trapped-ion-mobility-mass spectrometry
    Baglai, Anna
    Gargano, Andrea F. G.
    Jordens, Jan
    Mengerink, Ynze
    Honing, Maarten
    van der Wal, Sjoerd
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1530 : 90 - 103
  • [29] Tandem mass spectrometry and ion mobility mass spectrometry for the analysis of molecular sequence and architecture of hyperbranched glycopolymers
    Liu, Xiumin
    Cool, Lydia R.
    Lin, Kenneth
    Kasko, Andrea M.
    Wesdemiotis, Chrys
    ANALYST, 2015, 140 (04) : 1182 - 1191
  • [30] Study of Electrochemical Oxidation of Xanthohumol by Ultra-Performance Liquid Chromatography Coupled to High Resolution Tandem Mass Spectrometry and Ion Mobility Mass Spectrometry
    Guido, Luis F.
    Carvalho, Daniel O.
    Taborsky, Jakub
    Skopalova, Jana
    Saldanha, Helena M. E. B.
    Bednar, Petr
    CHROMATOGRAPHIA, 2015, 78 (19-20) : 1233 - 1243