Caudal vena cava measurements and fluid responsiveness in hospitalized cats with compromised hemodynamics and tissue hypoperfusion

被引:2
作者
Donati, Pablo A. [1 ,2 ,4 ]
Tunesi, Marcela [2 ]
Araos, Joaquin [3 ]
机构
[1] Univ Buenos Aires, Fac Ciencias Vet, Buenos Aires, Argentina
[2] Cooperat Vet Intens Care Unit UCICOOP, Buenos Aires, Argentina
[3] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY USA
[4] Cooperat Vet Intens Care Unit UCICOOP, Jose Maria Moreno 635,CP 1424,C1424AAG, Buenos Aires, Argentina
关键词
awake patients; critically ill cats; fluid responsiveness; spontaneous ventilation; CARDIAC-OUTPUT; HEALTHY CATS; ULTRASOUND; DOGS; ULTRASONOGRAPHY; CONSENSUS; THERAPY; SHOCK;
D O I
10.1111/vec.13272
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo evaluate the use of the caudal vena cava collapsibility index (CVCCI) and the inspiratory/minimum and expiratory/maximum diameters of the vena cava to predict fluid responsiveness in hospitalized, critically ill cats with hemodynamic and tissue perfusion abnormalities. DesignDiagnostic test study in a prospective cohort of hospitalized cats. SettingPrivate practice referral hospital. AnimalsTwenty-four hospitalized cats with spontaneous breathing and compromised hemodynamics and tissue hypoperfusion. InterventionsUltrasonographic examination before and after fluid expansion with 10 ml/kg of lactated Ringer's solution. Measurements and Main ResultsFluid responsiveness was evaluated using the velocity-time integral (VTI) of the subaortic blood flow, by measuring it before and after a fluid load of 10 ml/kg of lactated Ringer's solution. The CVCCI was calculated using the following formula: (maximum diameter - minimum diameter / maximum diameter) x 100. Ten cats were fluid responders (42 %) and 14 were nonresponders (58 %). The area under the receiver operating characteristic curve (AUROC) with their 95% confidence interval for the predictors and the best cutoff values were as follows: CVCCI, AUROC = 0.83 (0.66-1.00) and cutoff = 31%; inspiratory/minimum diameter, AUROC = 0.86 (0.70-1.00) and cutoff = 0.24 cm; expiratory/maximum diameter, AUROC = 0.88 (0.74-1.00) and cutoff = 0.22 cm. A significant lineal correlation was observed between the percentage of increase in VTI after expansion and CVCCI (r(s) = 0.68, P < 0.001), expiratory/maximum diameter (r(s) = -0.72, P < 0.001), and inspiratory/minimum diameter (r(s) = -0.71, P < 0.001). The intraobserver and interobserver variability was low for VTI, and the expiratory/maximum diameter and inspiratory/minimum diameter were high for CVCCI. ConclusionsCaudal vena cava measurements could be useful to predict the response to fluids in hospitalized cats with hemodynamic and tissue perfusion alterations. Additional studies are required to draw definitive conclusions about the role of these variables to guide fluid administration in cats.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [21] Superior vena cava collapsibility index as a predictor of fluid responsiveness: a systematic review with meta-analysis
    Krolicki, Tomasz
    Molsa, Maciej
    Tukiendorf, Andrzej
    Gawda, Ryszard
    Czarnik, Tomasz
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2024, 56 (03) : 169 - 176
  • [22] Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure
    Vieillard-Baron, Antoine
    Evrard, Bruno
    Repesse, Xavier
    Maizel, Julien
    Jacob, Christophe
    Goudelin, Marine
    Charron, Cyril
    Prat, Gwenael
    Slama, Michel
    Geri, Guillaume
    Vignon, Philippe
    INTENSIVE CARE MEDICINE, 2018, 44 (02) : 197 - 203
  • [23] Respiratory changes of the inferior vena cava diameter predict fluid responsiveness in spontaneously breathing patients with cardiac arrhythmias
    Perrine Bortolotti
    Delphine Colling
    Vincent Colas
    Benoit Voisin
    Florent Dewavrin
    Julien Poissy
    Patrick Girardie
    Maeva Kyheng
    Fabienne Saulnier
    Raphael Favory
    Sebastien Preau
    Annals of Intensive Care, 8
  • [24] Accuracy of Respiratory Variation in Inferior Vena Cava Diameter to Predict Fluid Responsiveness in Children Under Mechanical Ventilation
    Campos, Nathalia Barros
    de Lima, Licia Bertanha
    Ferraz, Isabel de Siqueira
    Nogueira, Roberto J. N.
    Brandao, Marcelo B.
    de Souza, Tiago H.
    PEDIATRIC CARDIOLOGY, 2024, 45 (06) : 1326 - 1333
  • [25] Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients
    Corl, Keith A.
    George, Naomi R.
    Romanoff, Justin
    Levinson, Andrew T.
    Chheng, Darin B.
    Merchant, Roland C.
    Levy, Mitchell M.
    Napoli, Anthony M.
    JOURNAL OF CRITICAL CARE, 2017, 41 : 130 - 137
  • [26] Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis
    Si, Xiang
    Xu, Hailin
    Liu, Zimeng
    Wu, Jianfeng
    Cao, Daiyin
    Chen, Juan
    Chen, Minying
    Liu, Yongjun
    Guan, Xiangdong
    ANESTHESIA AND ANALGESIA, 2018, 127 (05) : 1157 - 1164
  • [27] Development of a Deep Learning Network to Classify Inferior Vena Cava Collapse to Predict Fluid Responsiveness
    Blaivas, Michael
    Blaivas, Laura
    Philips, Gary
    Merchant, Roland
    Levy, Mitchell
    Abbasi, Adeel
    Eickhoff, Carsten
    Shapiro, Nathan
    Corl, Keith
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (08) : 1495 - 1504
  • [28] Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?
    Norair Airapetian
    Julien Maizel
    Ola Alyamani
    Yazine Mahjoub
    Emmanuel Lorne
    Melanie Levrard
    Nacim Ammenouche
    Aziz Seydi
    François Tinturier
    Eric Lobjoie
    Hervé Dupont
    Michel Slama
    Critical Care, 19
  • [29] Assessment of fluid responsiveness by inferior vena cava diameter variation in post-pneumonectomy patients
    Wang, Yan
    Jiang, Yinghou
    Wu, Hongning
    Wang, Runfeng
    Wang, Ying
    Du, Cheng
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (12): : 1922 - 1925
  • [30] Bedside sonographic measurement of the inferior vena cava caval index is a poor predictor of fluid responsiveness in emergency department patients
    Corl, Keith
    Napoli, Anthony M.
    Gardiner, Fenwick
    EMERGENCY MEDICINE AUSTRALASIA, 2012, 24 (05) : 534 - 539