Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis

被引:3
作者
Carneiro, Ana Luiza E. [1 ,5 ]
Reis, Isabella N. R. [1 ]
Bitencourt, Fernando Valentim [2 ,3 ]
Salgado, Daniela M. R. A. [1 ]
Costa, Claudio [1 ]
Spin-Neto, Rubens [4 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, BR- 05508000 Sao Paulo, Brazil
[2] Aarhus Univ, Dept Dent & Oral Hlth, Sect Oral Ecol & Inflammat, DK-8000 Aarhus, Denmark
[3] Steno Diabet Ctr Aarhus, DK-8200 Aarhus, Denmark
[4] Aarhus Univ, Dept Dent & Oral Hlth, Sect Oral Radiol & Endodont, DK-8000 Aarhus, Denmark
[5] Univ Sao Paulo, Sch Dent, Dept Oral Radiol, Av Prof Lineu Prestes, BR-05508000 Sao Paulo, SP, Brazil
关键词
cone-beam computed tomography; radiation dosage; dental implants; systematic review; COMPUTED-TOMOGRAPHY IMAGES; VOXEL SIZES; QUALITY; CBCT; DIMENSIONS; DENTISTRY; MAXILLARY;
D O I
10.1093/dmfr/twae007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those performed on standard and high-resolution CBCT protocols.Methods The literature search included four databases (Pubmed, Web of Science, Embase, and Scopus). Two reviewers independently screened titles/abstracts and full texts according to eligibility criteria, extracted the data, and examined the methodological quality. Risk of bias assessment was performed using the Quality Assessment Tool For In Vitro Studies. Random-effects meta-analysis was used for pooling measurement error data.Results The initial search yielded 4684 titles. In total, 13 studies were included in the systematic review, representing a total of 81 samples, while 9 studies were included in the meta-analysis. The risk of bias ranged from medium to low. The main results across the studies indicate a strong consistency in linear measurements performed on low-dose images in relation to the reference methods. The overall pooled planning measurement error from low-dose CBCT protocols was -0.24 mm (95% CI, -0.52 to 0.04) with a high level of heterogeneity, showing a tendency for underestimation of real values. Various studies found no significant differences in measurements across different protocols (eg, voxel sizes, mA settings, or dose levels), regions (incisor, premolar, molar) and types (height vs. width). Some studies, however, noted exceptions in measurements performed on the posterior mandible.Conclusion Low-dose CBCT protocols offer adequate precision and accuracy of linear measurements for implant planning. Nevertheless, diagnostic image quality needs must be taken into consideration when choosing a low-dose CBCT protocol.
引用
收藏
页码:207 / 221
页数:15
相关论文
共 46 条
  • [1] Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls
    Al-Ekrish, Asmaa A.
    [J]. SAUDI DENTAL JOURNAL, 2012, 24 (3-4) : 127 - 134
  • [2] Optimization of cone beam computed tomography image quality in implant dentistry
    Alawaji, Yasmine
    MacDonald, David S.
    Giannelis, Georgios
    Ford, Nancy L.
    [J]. CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2018, 4 (06): : 268 - 278
  • [3] Evaluation of Health or Pathology of Bilateral Maxillary Sinuses in Patients Referred for Cone Beam Computed Tomography Using a Low-Dose Protocol
    Bornstein, Michael M.
    Yeung, Andy Wai Kan
    Tanaka, Ray
    von Arx, Thomas
    Jacobs, Reinhilde
    Khong, Pek-Lan
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (05) : 699 - 710
  • [4] Cone Beam Computed Tomography in Implant Dentistry: A Systematic Review Focusing on Guidelines, Indications, and Radiation Dose Risks
    Bornstein, Michael M.
    Scarfe, William C.
    Vaughn, Vida M.
    Jacobs, Reinhilde
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 55 - 77
  • [5] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    [J]. INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [6] Influence of Low-Dose Protocols of CBCT on Dental Implant Planning
    de Castro, Hebert Sampaio
    Kehrwald, Ricardo
    Matheus, Ricardo Alves
    Gomes, Amanda Farias
    Queiroz, Polyane Mazucatto
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 307 - 312
  • [7] Durack Conor, 2012, Braz. Dent. J., V23, P179
  • [8] Effect of Milliamperage Reduction on Pre-surgical Implant Planning Using Cone Beam Computed Tomography by Surgeons of Varying Experience
    El Sahili N.
    David-Tchouda S.
    Thoret S.
    Nasseh I.
    Berberi A.
    Fortin T.
    [J]. Journal of Maxillofacial and Oral Surgery, 2018, 17 (4) : 520 - 530
  • [9] El Sahili Nabil, 2018, Open Dent J, V12, P94, DOI 10.2174/1874210601812010094
  • [10] Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review
    Fokas, George
    Vaughn, Vida M.
    Scarfe, William C.
    Bornstein, Michael M.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 393 - 415