Quantification of Hepatic Steatosis on Dual-Energy CT in Comparison With MRI mDIXON-Quant Sequence in Breast Cancer

被引:1
作者
Wang, Xiaoxia [1 ]
Pan, Xianjun [2 ]
Zhou, Wenqi [2 ]
Jing, Zhouhong [2 ]
Yu, Feng [2 ]
Wang, Yali [2 ]
Zeng, Junjie [2 ]
Wu, Jiaxing [3 ]
Zeng, Xiaohua [2 ,4 ]
Zhang, Jiuquan [1 ]
机构
[1] Chongqing Univ, Canc Hosp, Dept Radiol, Chongqing Key Lab Intelligent Oncol Breast Canc iC, 181 Hanyu Rd, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Canc Hosp, Breast Canc Ctr, Chongqing, Peoples R China
[3] Siemens Healthineers, Shanghai, Peoples R China
[4] Chongqing Univ, Canc Hosp, Dept Breast Canc Ctr, 181 Hanyu Rd, Chongqing 400030, Peoples R China
关键词
breast neoplasms; fatty liver; drug therapy; tomography; x-ray computed; magnetic resonance imaging; FATTY LIVER-DISEASE; MULTIMATERIAL DECOMPOSITION ALGORITHM; FRACTION; PREVALENCE; DIAGNOSIS;
D O I
10.1097/RCT.0000000000001529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The study aimed to evaluate the correlation and diagnostic value of liver fat quantification in unenhanced dual-energy CT (DECT) using quantitative magnetic resonance imaging (MRI) mDIXON-Quant sequence as reference standard in patients with breast cancer.Methods: Patients with breast cancer were prospectively recruited between June 2018 and April 2020. Each patient underwent liver DECT and MRI mDIXON-Quant examination. The DECT-fat volume fraction (FVF) and liver-spleen attenuation differences were compared with the MRI-proton density fat fraction using scatterplots, Bland-Altman plots, and concordance correlation coefficient. Receiver operating characteristic curves were established to determine the diagnostic accuracy of hepatic steatosis by DECT.Results: A total of 216 patients with breast cancer (mean age, 50.08 +/- 9.33 years) were evaluated. The DECT-FVF correlated well with MRI-proton density fat fraction (r(2) = 0.902; P < 0.001), which was higher than the difference in liver-spleen attenuation (r(2) = 0.728; P < 0.001). Bland-Altman analysis revealed slight positive bias; the mean difference was 3.986. The DECT-FVF yielded an average concordance correlation coefficient of 0.677, which was higher than the difference of liver-spleen attenuation (-0.544). The DECT-FVF and the difference in liver-spleen attenuation both lead to mild overestimation of hepatic steatosis. The areas under the curve of DECT-FVF (0.956) were higher than the difference in liver-spleen attenuation (0.807) in identifying hepatic steatosis (P < 0.001).Conclusions: Dual-energy CT-FVF may serve as a reliable screening and quantitative tool for hepatic steatosis in patients with breast cancer.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 33 条
  • [31] Diagnostic accuracy of color-coded virtual noncalcium dual-energy CT for the assessment of bone marrow edema in sacral insufficiency fracture in comparison to MRI
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Bucher, Andreas M.
    Huizinga, Nicole A.
    Wichmann, Julian L.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [32] Dual-Phase Dual-Energy CT in Patients Treated with Erlotinib for Advanced Non-Small Cell Lung Cancer: Possible Benefits of Iodine Quantification in Response Assessment
    Baxa, Jan
    Matouskova, Tana
    Krakorova, Gabriela
    Schmidt, Bernhard
    Flohr, Thomas
    Sedlmair, Martin
    Bejcek, Jiri
    Ferda, Jiri
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2828 - 2836
  • [33] Comparison of contrast-enhanced CT, dual-layer detector spectral CT, and whole-body MRI in suspected metastatic breast cancer: a prospective diagnostic accuracy study
    Thomas Winther Buus
    Finn Rasmussen
    Hanne Marie Nellemann
    Vibeke Løgager
    Anders Bonde Jensen
    Katrine Rye Hauerslev
    Peer Christiansen
    Erik Morre Pedersen
    European Radiology, 2021, 31 : 8838 - 8849