Quantification of Hepatic Steatosis on Dual-Energy CT in Comparison With MRI mDIXON-Quant Sequence in Breast Cancer

被引:1
作者
Wang, Xiaoxia [1 ]
Pan, Xianjun [2 ]
Zhou, Wenqi [2 ]
Jing, Zhouhong [2 ]
Yu, Feng [2 ]
Wang, Yali [2 ]
Zeng, Junjie [2 ]
Wu, Jiaxing [3 ]
Zeng, Xiaohua [2 ,4 ]
Zhang, Jiuquan [1 ]
机构
[1] Chongqing Univ, Canc Hosp, Dept Radiol, Chongqing Key Lab Intelligent Oncol Breast Canc iC, 181 Hanyu Rd, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Canc Hosp, Breast Canc Ctr, Chongqing, Peoples R China
[3] Siemens Healthineers, Shanghai, Peoples R China
[4] Chongqing Univ, Canc Hosp, Dept Breast Canc Ctr, 181 Hanyu Rd, Chongqing 400030, Peoples R China
关键词
breast neoplasms; fatty liver; drug therapy; tomography; x-ray computed; magnetic resonance imaging; FATTY LIVER-DISEASE; MULTIMATERIAL DECOMPOSITION ALGORITHM; FRACTION; PREVALENCE; DIAGNOSIS;
D O I
10.1097/RCT.0000000000001529
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The study aimed to evaluate the correlation and diagnostic value of liver fat quantification in unenhanced dual-energy CT (DECT) using quantitative magnetic resonance imaging (MRI) mDIXON-Quant sequence as reference standard in patients with breast cancer.Methods: Patients with breast cancer were prospectively recruited between June 2018 and April 2020. Each patient underwent liver DECT and MRI mDIXON-Quant examination. The DECT-fat volume fraction (FVF) and liver-spleen attenuation differences were compared with the MRI-proton density fat fraction using scatterplots, Bland-Altman plots, and concordance correlation coefficient. Receiver operating characteristic curves were established to determine the diagnostic accuracy of hepatic steatosis by DECT.Results: A total of 216 patients with breast cancer (mean age, 50.08 +/- 9.33 years) were evaluated. The DECT-FVF correlated well with MRI-proton density fat fraction (r(2) = 0.902; P < 0.001), which was higher than the difference in liver-spleen attenuation (r(2) = 0.728; P < 0.001). Bland-Altman analysis revealed slight positive bias; the mean difference was 3.986. The DECT-FVF yielded an average concordance correlation coefficient of 0.677, which was higher than the difference of liver-spleen attenuation (-0.544). The DECT-FVF and the difference in liver-spleen attenuation both lead to mild overestimation of hepatic steatosis. The areas under the curve of DECT-FVF (0.956) were higher than the difference in liver-spleen attenuation (0.807) in identifying hepatic steatosis (P < 0.001).Conclusions: Dual-energy CT-FVF may serve as a reliable screening and quantitative tool for hepatic steatosis in patients with breast cancer.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 33 条
  • [1] Comparison of CT and magnetic resonance mDIXON-Quant sequence in the diagnosis of mild hepatic steatosis
    Zhang, Yong
    Wang, Chao
    Duanmu, Yangyang
    Zhang, Chenxin
    Zhao, Wei
    Wang, Ling
    Cheng, Xiaoguang
    Veronese, Nicola
    Guglielmi, Giuseppe
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1091)
  • [2] Evaluation of hepatic steatosis using dual-energy CT with MR comparison
    Sun, Taotao
    Lin, Xiaozhu
    Chen, Kemin
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2014, 19 : 1377 - 1385
  • [3] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Beck, Stefanie
    Jahn, Laurenz
    Deniffel, Dominik
    Riederer, Isabelle
    Sauter, Andreas
    Makowski, Marcus R.
    Pfeiffer, Daniela
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1738 - 1747
  • [4] Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT
    Catania, Roberta
    Jia, Leo
    Haghshomar, Maryam
    Miller, Frank H.
    Borhani, Amir A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [5] Quantification of Hepatic Steatosis With Dual-Energy Computed Tomography Comparison With Tissue Reference Standards and Quantitative Magnetic Resonance Imaging in the ob/ob Mouse
    Artz, Nathan S.
    Hines, Catherine D. G.
    Brunner, Stephen T.
    Agni, Rashmi M.
    Kuehn, Jens-Peter
    Roldan-Alzate, Alejandro
    Chen, Guang-Hong
    Reeder, Scott B.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (10) : 603 - 610
  • [6] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Stefanie Beck
    Laurenz Jahn
    Dominik Deniffel
    Isabelle Riederer
    Andreas Sauter
    Marcus R. Makowski
    Daniela Pfeiffer
    Journal of Digital Imaging, 2022, 35 : 1738 - 1747
  • [7] Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study
    Jacobsen, Megan C.
    Schellingerhout, Dawid
    Wood, Cayla A.
    Tamm, Eric P.
    Godoy, Myrna C.
    Sun, Jia
    Cody, Dianna D.
    RADIOLOGY, 2018, 287 (01) : 224 - 234
  • [8] Virtual noncontrast images derived from dual-energy CT for assessment of hepatic steatosis in living liver donors
    Kang, Hyo-Jin
    Lee, Dong Ho
    Park, Sae Jin
    Han, Joon Koo
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139
  • [9] Can Dual-energy CT-based Virtual Monoenergetic Imaging Improve the Assessment of Hypodense Liver Metastases in Patients With Hepatic Steatosis?
    Lenga, Lukas
    Lange, Marvin
    Arendt, Christophe T.
    Yel, Ibrahim
    Booz, Christian
    Durden, James
    Leithner, Doris
    Vogl, Thomas J.
    Albrecht, Moritz H.
    Martin, Simon S.
    ACADEMIC RADIOLOGY, 2021, 28 (06) : 769 - 777
  • [10] Advanced imaging assessment of gout: comparison of dual-energy CT and MRI with anatomical pathology
    Chhana, Ashika
    Doyle, Anthony
    Sevao, Amy
    Amirapu, Satya
    Riordan, Peter
    Dray, Michael
    McGlashan, Sue
    Cornish, Jillian
    Dalbeth, Nicola
    ANNALS OF THE RHEUMATIC DISEASES, 2018, 77 (04) : 629 - 630