Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality

被引:1
|
作者
Hwang, Seokbin [1 ]
Lee, Suk-joong [2 ,3 ]
Kim, Sungmin [4 ]
机构
[1] Univ Ulsan, Dept Elect Elect & Comp Engn, 93 Daehak Ro, Ulsan 44610, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Orthopaed Surg, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[3] Gyeongsang Natl Univ, Changwon Hosp, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[4] Univ Ulsan, Dept Biomed Engn, 93 Daehak Ro, Ulsan 44610, South Korea
基金
新加坡国家研究基金会;
关键词
HoloLens; mixed reality; pedicle screw placement; surgical navigation; ACCURACY; METAANALYSIS;
D O I
10.1007/s12555-023-0083-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inaccurate screw insertion has been a major concern in pedicle screw placement in spinal surgery because of the potential for postoperative complications. Efforts to improve screw insertion have led to the development of novel surgical navigation systems. However, current surgical navigation systems have several problems in that the attention of surgeons is frequently interrupted during surgery, and complications occur in their depth perception because of the limitations of 2D monitors. This study proposes a surgical navigation system to address these issues using mixed reality (MR)-based smart glasses. We developed a navigation system that provides 3D visualization of the surgical tool with respect to the patient's anatomy. It utilizes preoperative surgical planning data to provide visual feedback and guidance. An orthopedic surgeon performed pedicle screw placement with the navigation system in two different environments, using Microsoft HoloLens (HoloLens) and a 2D monitor. The results were evaluated according to procedural time, translational error, angular error, and clinical accuracy. The mean procedural time was 111.3 +/- 52.7 s with the HoloLens and 192.1 +/- 104.0 s with the 2D monitor. The mean translational error was 2.14 +/- 1.13 mm at the entry and 3.14 +/- 0.90 mm at the target with HoloLens. With the 2D monitor, the mean translational error was 2.10 +/- 0.97 mm and 3.41 +/- 2.16 mm at the entry and the target, respectively. The mean angular error was 6.44 +/- 1.94 deg with HoloLens and 7.14 +/- 4.20 deg with the 2D monitor. All screws were inserted intrapedicularly in both environments. The navigation system enables free visualization, reflects the human eye's perspective, and retains the advantages of MR-based smart glasses. A navigation system compatible with minimally invasive surgery should be developed in the future.
引用
收藏
页码:3983 / 3993
页数:11
相关论文
共 50 条
  • [41] Tracked Ultrasound Snapshots in Percutaneous Pedicle Screw Placement Navigation: A Feasibility Study
    Ungi, Tamas
    Moult, Eric
    Schwab, Joseph H.
    Fichtinger, Gabor
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) : 4047 - 4055
  • [42] Validation of a surgical navigation system for hypertensive intracerebral hemorrhage based on mixed reality using an automatic registration method
    Zhou, Zeyang
    Yang, Zhiyong
    Jiang, Shan
    Zhuo, Jie
    Li, Yuhua
    Zhu, Tao
    Ma, Shixing
    Zhang, Jingqi
    VIRTUAL REALITY, 2023, 27 (03) : 2059 - 2071
  • [43] Validation of a surgical navigation system for hypertensive intracerebral hemorrhage based on mixed reality using an automatic registration method
    Zeyang Zhou
    Zhiyong Yang
    Shan Jiang
    Jie Zhuo
    Yuhua Li
    Tao Zhu
    Shixing Ma
    Jingqi Zhang
    Virtual Reality, 2023, 27 : 2059 - 2071
  • [44] Accuracy of pedicle screw placement based on preoperative computed tomography versus intraoperative data set acquisition for spinal navigation system
    Liu, Hao
    Chen, Weikai
    Liu, Tao
    Meng, Bin
    Yang, Huilin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02):
  • [45] Mixed Reality Navigation System for Oral Implant Surgery Based on TopoTag
    Zhang, Xiaoyong
    Guo, Yanbin
    Liu, Yingbin
    Wang, Guoping
    BIOPHYSICAL SOCIETY OF GUANGDONG PROVINCE ACADEMIC FORUM: PRECISE PHOTONS AND LIFE HEALTH, PPLH 2022, 2023, 12603
  • [46] Guideline for Thoracolumbar Pedicle Screw Placement Assisted by Orthopaedic Surgical Robot
    Tian, Wei
    Liu, Ya-jun
    Liu, Bo
    He, Da
    Wu, Jing-ye
    Han, Xiao-guang
    Zhao, Jing-wei
    Fan, Ming-xing
    Cai, Lin
    Cao, Xiang-yang
    Fang, Huan-sheng
    Gao, Chun-zheng
    Hao, Ding-jun
    Hu, Yong-cheng
    Li, Ming
    Li, Chun-xia
    Li, Chun-de
    Li, Kai-nan
    Liao, Yi
    Liu, Hao
    Liu, Bao-ge
    Liu, Jun
    Liu, Shi-dong
    Liu, Xin-yu
    Liu, Ya-Jun
    Ma, Xin-long
    Shen, Cai-liang
    Shen, Hong-xing
    Song, Yue-ming
    Sun, Tian-sheng
    Wang, Yue
    Xia, Ya-yi
    Xu, Jian-zhong
    Yang, Hui-lin
    Yang, Xue-jun
    Yin, Guo-yong
    Zhang, Shu-dong
    Zhang, Wei-guo
    Zhao, Yu
    Zhu, Yue
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 153 - 159
  • [47] Augmented reality-navigated pedicle screw placement: a cadaveric pilot study
    José Miguel Spirig
    Simon Roner
    Florentin Liebmann
    Philipp Fürnstahl
    Mazda Farshad
    European Spine Journal, 2021, 30 : 3731 - 3737
  • [48] Accuracy of augmented reality-assisted pedicle screw placement: a systematic review
    Youssef, Salma
    McDonnell, Jake M.
    Wilson, Kielan V.
    Turley, Luke
    Cunniffe, Grainne
    Morris, Seamus
    Darwish, Stacey
    Butler, Joseph S.
    EUROPEAN SPINE JOURNAL, 2024, 33 (03) : 974 - 984
  • [49] Accuracy of augmented reality-assisted pedicle screw placement: a systematic review
    Salma Youssef
    Jake M. McDonnell
    Kielan V. Wilson
    Luke Turley
    Gráinne Cunniffe
    Seamus Morris
    Stacey Darwish
    Joseph S. Butler
    European Spine Journal, 2024, 33 : 974 - 984
  • [50] Vertebral templates combined with augmented reality technology for guidance of pedicle screw placement
    Wu, Zhanglei
    Wang, Shuyi
    Chen, Zan
    Zhang, Can
    Shao, Hongran
    Fu, Xiaoni
    Ma, Bangfeng
    Yu, Jiaqi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (12): : 414 - 422