Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality

被引:1
|
作者
Hwang, Seokbin [1 ]
Lee, Suk-joong [2 ,3 ]
Kim, Sungmin [4 ]
机构
[1] Univ Ulsan, Dept Elect Elect & Comp Engn, 93 Daehak Ro, Ulsan 44610, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Orthopaed Surg, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[3] Gyeongsang Natl Univ, Changwon Hosp, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[4] Univ Ulsan, Dept Biomed Engn, 93 Daehak Ro, Ulsan 44610, South Korea
基金
新加坡国家研究基金会;
关键词
HoloLens; mixed reality; pedicle screw placement; surgical navigation; ACCURACY; METAANALYSIS;
D O I
10.1007/s12555-023-0083-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inaccurate screw insertion has been a major concern in pedicle screw placement in spinal surgery because of the potential for postoperative complications. Efforts to improve screw insertion have led to the development of novel surgical navigation systems. However, current surgical navigation systems have several problems in that the attention of surgeons is frequently interrupted during surgery, and complications occur in their depth perception because of the limitations of 2D monitors. This study proposes a surgical navigation system to address these issues using mixed reality (MR)-based smart glasses. We developed a navigation system that provides 3D visualization of the surgical tool with respect to the patient's anatomy. It utilizes preoperative surgical planning data to provide visual feedback and guidance. An orthopedic surgeon performed pedicle screw placement with the navigation system in two different environments, using Microsoft HoloLens (HoloLens) and a 2D monitor. The results were evaluated according to procedural time, translational error, angular error, and clinical accuracy. The mean procedural time was 111.3 +/- 52.7 s with the HoloLens and 192.1 +/- 104.0 s with the 2D monitor. The mean translational error was 2.14 +/- 1.13 mm at the entry and 3.14 +/- 0.90 mm at the target with HoloLens. With the 2D monitor, the mean translational error was 2.10 +/- 0.97 mm and 3.41 +/- 2.16 mm at the entry and the target, respectively. The mean angular error was 6.44 +/- 1.94 deg with HoloLens and 7.14 +/- 4.20 deg with the 2D monitor. All screws were inserted intrapedicularly in both environments. The navigation system enables free visualization, reflects the human eye's perspective, and retains the advantages of MR-based smart glasses. A navigation system compatible with minimally invasive surgery should be developed in the future.
引用
收藏
页码:3983 / 3993
页数:11
相关论文
共 50 条
  • [21] Augmented reality-navigated pedicle screw placement: a cadaveric pilot study
    Spirig, Jose Miguel
    Roner, Simon
    Liebmann, Florentin
    Furnstahl, Philipp
    Farshad, Mazda
    EUROPEAN SPINE JOURNAL, 2021, 30 (12) : 3731 - 3737
  • [22] Meta-analysis of fluoroscopic and navigation-based cervical pedicle screw placement
    Soliman, Mohamed A. R.
    Khan, Asham
    Pollina, John
    Mullin, Jeffrey P.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (03) : 522 - 523
  • [23] Surgical navigation system for brachytherapy based on mixed reality using a novel stereo registration method
    Zhou, Zeyang
    Jiang, Shan
    Yang, Zhiyong
    Xu, Bin
    Jiang, Bowen
    VIRTUAL REALITY, 2021, 25 (04) : 975 - 984
  • [24] Surgical navigation system for brachytherapy based on mixed reality using a novel stereo registration method
    Zeyang Zhou
    Shan Jiang
    Zhiyong Yang
    Bin Xu
    Bowen Jiang
    Virtual Reality, 2021, 25 : 975 - 984
  • [25] A robotic system for spine surgery positioning and pedicle screw placement
    Zhang, Jian
    Li, Weishi
    Hu, Lei
    Zhao, Yu
    Wang, Tianmiao
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (04)
  • [26] Augmented reality navigation for spinal pedicle screw instrumentation using intraoperative 3D imaging
    Mueller, Fabio
    Roner, Simon
    Liebmann, Florentin
    Spirig, Jose M.
    Fuernstahl, Philipp
    Farshad, Mazda
    SPINE JOURNAL, 2020, 20 (04) : 621 - 628
  • [27] Initial Single-Institution Experience With a Novel Robotic-Navigation System for Thoracolumbar Pedicle Screw and Pelvic Screw Placement With 643 Screws
    Jain, Deeptee
    Manning, Jordan
    Lord, Elizabeth
    Protopsaltis, Themistocles
    Kim, Yong
    Buckland, Aaron J.
    Bendo, John
    Fischer, Charla
    Goldstein, Jeffrey
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2019, 13 (05) : 459 - 463
  • [28] Pedicle Screw Placement Using Augmented Reality Surgical Navigation With Intraoperative 3D Imaging A First In-Human Prospective Cohort Study
    Elmi-Terander, Adrian
    Burstrom, Gustav
    Nachabe, Rami
    Skulason, Halldor
    Pedersen, Kyrre
    Fagerlund, Michael
    Stahl, Fredrik
    Charalampidis, Anastasios
    Soderman, Michael
    Holmin, Staffan
    Babic, Drazenko
    Jenniskens, Inge
    Edstrom, Erik
    Gerdhem, Paul
    SPINE, 2019, 44 (07) : 517 - 525
  • [29] The Efficacy of Immersive Virtual Reality Surgical Simulator Training for Pedicle Screw Placement: A Randomized Double-Blind Controlled Trial
    Xin, Baoquan
    Chen, Guanghui
    Wang, Yang
    Bai, Guangjian
    Gao, Xin
    Chu, Jianjun
    Xiao, Jianru
    Liu, Tielong
    WORLD NEUROSURGERY, 2019, 124 : E324 - E330
  • [30] Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis
    Xiao-tong Meng
    Xiao-fei Guan
    Hai-long Zhang
    Shi-sheng He