Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality

被引:1
|
作者
Hwang, Seokbin [1 ]
Lee, Suk-joong [2 ,3 ]
Kim, Sungmin [4 ]
机构
[1] Univ Ulsan, Dept Elect Elect & Comp Engn, 93 Daehak Ro, Ulsan 44610, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Orthopaed Surg, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[3] Gyeongsang Natl Univ, Changwon Hosp, 11 Samjeongja Ro, Chang Won, Gyeongsangnam D, South Korea
[4] Univ Ulsan, Dept Biomed Engn, 93 Daehak Ro, Ulsan 44610, South Korea
基金
新加坡国家研究基金会;
关键词
HoloLens; mixed reality; pedicle screw placement; surgical navigation; ACCURACY; METAANALYSIS;
D O I
10.1007/s12555-023-0083-6
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Inaccurate screw insertion has been a major concern in pedicle screw placement in spinal surgery because of the potential for postoperative complications. Efforts to improve screw insertion have led to the development of novel surgical navigation systems. However, current surgical navigation systems have several problems in that the attention of surgeons is frequently interrupted during surgery, and complications occur in their depth perception because of the limitations of 2D monitors. This study proposes a surgical navigation system to address these issues using mixed reality (MR)-based smart glasses. We developed a navigation system that provides 3D visualization of the surgical tool with respect to the patient's anatomy. It utilizes preoperative surgical planning data to provide visual feedback and guidance. An orthopedic surgeon performed pedicle screw placement with the navigation system in two different environments, using Microsoft HoloLens (HoloLens) and a 2D monitor. The results were evaluated according to procedural time, translational error, angular error, and clinical accuracy. The mean procedural time was 111.3 +/- 52.7 s with the HoloLens and 192.1 +/- 104.0 s with the 2D monitor. The mean translational error was 2.14 +/- 1.13 mm at the entry and 3.14 +/- 0.90 mm at the target with HoloLens. With the 2D monitor, the mean translational error was 2.10 +/- 0.97 mm and 3.41 +/- 2.16 mm at the entry and the target, respectively. The mean angular error was 6.44 +/- 1.94 deg with HoloLens and 7.14 +/- 4.20 deg with the 2D monitor. All screws were inserted intrapedicularly in both environments. The navigation system enables free visualization, reflects the human eye's perspective, and retains the advantages of MR-based smart glasses. A navigation system compatible with minimally invasive surgery should be developed in the future.
引用
收藏
页码:3983 / 3993
页数:11
相关论文
共 50 条
  • [1] Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality
    Seokbin Hwang
    Suk-joong Lee
    Sungmin Kim
    International Journal of Control, Automation and Systems, 2023, 21 : 3983 - 3993
  • [2] Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study
    Ma, Longfei
    Zhao, Zhe
    Chen, Fang
    Zhang, Boyu
    Fu, Ligong
    Liao, Hongen
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (12) : 2205 - 2215
  • [3] Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study
    Longfei Ma
    Zhe Zhao
    Fang Chen
    Boyu Zhang
    Ligong Fu
    Hongen Liao
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 2205 - 2215
  • [4] A Novel Pedicle Screw Placement Surgery Based on Integration of Surgical Guides and Augmented Reality
    Kong, Huiyang
    Wang, Shuyi
    Zhang, Can
    Chen, Zan
    Wu, Zhanglei
    Wang, Jiayu
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2025,
  • [5] Analysis of CT-based Navigation System for Pedicle Screw Placement
    Hodges, Scott D.
    Eck, Jason C.
    Newton, Danette
    ORTHOPEDICS, 2012, 35 (08) : E1221 - E1224
  • [6] Mixed Reality-Based Navigation for Pedicle Screw Placement: A Preliminary Study Using a 3D-Printed Spine Model
    Ohashi, Masayuki
    Sato, Masayuki
    Tashi, Hideki
    Minato, Keitaro
    Makino, Tatsuo
    Kawashima, Hiroyuki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [7] Feasibility and Accuracy of Thoracolumbar Minimally Invasive Pedicle Screw Placement With Augmented Reality Navigation Technology
    Elmi-Terander, Adrian
    Nachabe, Rami
    Skulason, Halldor
    Pedersen, Kyrre
    Soderman, Michael
    Racadio, John
    Babic, Drazenko
    Gerdhem, Paul
    Edstrom, Erik
    SPINE, 2018, 43 (14) : 1018 - 1023
  • [8] Ultrasound Image Guided and Mixed Reality-Based Surgical System With Real-Time Soft Tissue Deformation Computing for Robotic Cervical Pedicle Screw Placement
    Tu, Puxun
    Qin, Chunxia
    Guo, Yan
    Li, Dongyuan
    Lungu, Abel J.
    Wang, Huixiang
    Chen, Xiaojun
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (08) : 2593 - 2603
  • [9] Design and validation of a surgical navigation system for brachytherapy based on mixed reality
    Zhou, Zeyang
    Yang, Zhiyong
    Jiang, Shan
    Zhang, Fujun
    Yan, Huzheng
    MEDICAL PHYSICS, 2019, 46 (08) : 3709 - 3718
  • [10] Augmented reality-based navigation increases precision of pedicle screw insertion
    Dennler, Cyrill
    Jaberg, Laurenz
    Spirig, Jose
    Agten, Christoph
    Gotschi, Tobias
    Furnstahl, Philipp
    Farshad, Mazda
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)