Study on Sustentaculum Tali Fragment Constancy in Intraarticular Calcaneus Fracture

被引:4
作者
Yan, Hongfei [1 ]
Na, Ho Dong [1 ]
Park, Jeong Jin [1 ]
Park, Chul Hyun [1 ,2 ]
机构
[1] Yeungnam Univ, Coll Med, Dept Orthopaed Surg, Daegu, South Korea
[2] Yeungnam Univ, Dept Orthopaed Surg, Med Ctr, Hyeonchungno 170, Daegu 42415, South Korea
关键词
calcaneus fracture; constant fragment; sustentaculum tali fragment; CONTACT CHARACTERISTICS; SANDERS CLASSIFICATION; COMPUTED-TOMOGRAPHY; INTERNAL-FIXATION; REDUCTION; JOINT; ANKLE;
D O I
10.1097/BOT.0000000000002657
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To establish reproducible measurements of the sustentaculum tali (ST) fragment regarding fracture classification and patient-related factors.Design: Retrospective.Setting: Trauma center, University Hospital.Patients: A retrospective analysis of the 142 fractured calcanei of 122 patients (101 men and 21 women) treated at our institution between 2012 and 2020 was performed. As control, 62 unaffected calcanei were used.Intervention: Radiographic images were evaluated twice within 2 weeks by 2 orthopaedic surgeons and 1 postgraduate student. Angulation and diastasis were used to distinguish ST fragment constancy based on computed tomography. Using these parameters, the prevalence of inconstant ST fragments was assessed. We also analyzed factors related to ST fragment inconstancy. Patient factors included age, body mass index, smoking, and diabetes. Radiographic factors included the Sanders classification, location of the outermost fracture line of the posterior facet, presence of an intraarticular fracture of the ST, and ST fragment width.Main Outcome Measurements: Angulation and diastasis were used to confirm the ST fragment constancy. Potential risks for inconstant ST fragment subsequently defined.Results:According to the criteria, ST fragment inconstancy was observed in 34.5%. ST fragment width was significantly smaller in the inconstant group (P < 0.001). Severe comminution of the posterior facet (P < 0.05), intraarticular fracture of the ST (P < 0.001), and diabetes (P < 0.05) were significantly higher in the inconstant group. The cut-off value of the ST fragment width was 20.5 mm.Conclusions: In intraarticular calcaneus fractures, small ST fragment width, comminuted fracture, intraarticular fracture of the ST, and diabetes were associated with the inconstant group. The ST fragment was expected to be inconstant when the width was less than 20.5 mm.
引用
收藏
页码:E422 / E427
页数:6
相关论文
共 25 条
  • [1] Sustentaculum Tali Screw Placement for Calcaneus Fractures - Different Navigation Procedures Compared to the Conventional Technique
    Gras, F.
    Marintschev, I.
    Wilharm, A.
    Lindner, R.
    Klos, K.
    Mueckley, T.
    Hofmann, G. O.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (03): : 309 - 318
  • [2] The impact of sustentaculum tali fracture on clinical outcome in patients affected by isolated calcaneal fractures
    Giacomo Sani
    Niccolò Giabbani
    Luigi Zanna
    Roberto Buzzi
    Angelica Sofia Pio
    Vieri Rastrelli
    Cosimo Nardi
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 1017 - 1024
  • [3] The impact of sustentaculum tali fracture on clinical outcome in patients affected by isolated calcaneal fractures
    Sani, Giacomo
    Giabbani, Niccolo
    Zanna, Luigi
    Buzzi, Roberto
    Pio, Angelica Sofia
    Rastrelli, Vieri
    Nardi, Cosimo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (02) : 1017 - 1024
  • [4] Minimally Invasive Osteosynthesis of Intraarticular Calcaneus Fracture Augmented by Femoral Head Allograft: A Retrospective Study
    Moussa, Mohamad K.
    Vuilletet, Emma
    Alayane, Ali
    Boushnak, Mohammad O.
    Fleurette, Justine
    Nicolas, Nicolas
    Thiongo, Maurice
    Missaoui, Zied
    Kassab, Georges
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [5] Primary fusion in worker's compensation intraarticular calcaneus fracture. Prospective study of 169 consecutive cases
    Lopez-Oliva, Felipe
    Sanchez-Lorente, Tomas
    Fuentes-Sanz, Adela
    Aldomar-Sanz, Yolanda
    Forriol, Francisco
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 : S73 - S78
  • [6] Cannulated screw fixation and plate fixation for displaced intraarticular calcaneus fracture: A meta-analysis of randomized controlled trials
    Fan, Baoyou
    Zhou, Xianhu
    Wei, Zhijian
    Ren, Yiming
    Lin, Wei
    Hao, Yan
    Shi, Guidong
    Feng, Shiqing
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 34 : 64 - 72
  • [7] RESULTS OF FIXATION IN THE TREATMENT OF CALCANEUS FRACTURE: A CROSSSECTIONAL STUDY
    Zakariaiy, Amir
    Abrisham, Seyed Mohammad Jalil
    Sobhan, Mohammad Reza
    ACTA BIOCLINICA, 2024, 14 (27): : 113 - 133
  • [8] The epidemiology and clinical features of calcaneus osteomyelitis following calcaneus fracture: a retrospective study of 127 cases
    Huang, Kai
    Guo, Qiaofeng
    Zhu, Yansheng
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (03) : 3154 - 3161
  • [9] Contribution of arthroscopy to the treatment of intraarticular fracture of the distal radius: Retrospective study of 40 cases
    Christiaens, N.
    Nedellec, G.
    Guerre, E.
    Guillou, J.
    Demondion, X.
    Fontaine, C.
    Chantelot, C.
    HAND SURGERY & REHABILITATION, 2017, 36 (04) : 268 - 274
  • [10] A COMPUTATIONAL STUDY OF FRACTURE IN THE CALCANEUS UNDER VARIABLE IMPACT CONDITIONS
    Kantareddy, Sai Nithin Reddy
    Fielding, Rebecca A.
    Robinson, Michael J.
    Kraft, Reuben H.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 3, 2016,