Automated contouring and statistical process control for plan quality in a breast clinical trial

被引:3
|
作者
Baroudi, Hana [1 ,2 ,5 ]
Nguyen, Callistus I. Huy Minh [2 ]
Maroongroge, Sean [3 ]
Smith, Benjamin D. [4 ]
Niedzielski, Joshua S. [2 ]
Shaitelman, Simona F. [4 ]
Melancon, Adam [2 ]
Shete, Sanjay [1 ]
Whitaker, Thomas J. [2 ]
Mitchell, Melissa P. [4 ]
Arzu, Isidora Yvonne [4 ]
Duryea, Jack [2 ]
Hernandez, Soleil [1 ,2 ]
El Basha, Daniel [1 ,2 ]
Mumme, Raymond [2 ]
Netherton, Tucker [2 ]
Hoffman, Karen [4 ]
Court, Laurence [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, UTHlth Houston Grad Sch Biomed Sci, Houston, TX USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Breast Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1400 Pressler St,FCT8-6014, Houston, TX 77030 USA
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 28卷
基金
美国国家科学基金会;
关键词
Automated segmentation; Radiotherapy clinical trial; Breast cancer; Plan quality assurance; RADIOTHERAPY; TARGET; QA; SEGMENTATION;
D O I
10.1016/j.phro.2023.100486
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Automatic review of breast plan quality for clinical trials is time-consuming and has some unique challenges due to the lack of target contours for some planning techniques. We propose using an auto-contouring model and statistical process control to independently assess planning consistency in retrospective data from a breast radiotherapy clinical trial. Materials and methods: A deep learning auto-contouring model was created and tested quantitatively and qualitatively on 104 post-lumpectomy patients' computed tomography images (nnUNet; train/test: 80/20). The autocontouring model was then applied to 127 patients enrolled in a clinical trial. Statistical process control was used to assess the consistency of the mean dose to auto-contours between plans and treatment modalities by setting control limits within three standard deviations of the data's mean. Two physicians reviewed plans outside the limits for possible planning inconsistencies. Results: Mean Dice similarity coefficients comparing manual and auto-contours was above 0.7 for breast clinical target volume, supraclavicular and internal mammary nodes. Two radiation oncologists scored 95% of contours as clinically acceptable. The mean dose in the clinical trial plans was more variable for lymph node auto-contours than for breast, with a narrower distribution for volumetric modulated arc therapy than for 3D conformal treatment, requiring distinct control limits. Five plans (5%) were flagged and reviewed by physicians: one required editing, two had clinically acceptable variations in planning, and two had poor auto-contouring. Conclusions: An automated contouring model in a statistical process control framework was appropriate for assessing planning consistency in a breast radiotherapy clinical trial.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The Effect of Spiritual Group Therapy on the Quality of Life and Empowerment of Women with Breast Cancer: A Randomized Clinical Trial in Iran
    Momennasab, Marzieh
    Ghorbani, Fatemeh
    Yektatalab, Shahrzad
    Magharei, Mahboobeh
    Tehranineshat, Banafsheh
    JOURNAL OF RELIGION & HEALTH, 2024, 63 (02): : 1504 - 1522
  • [22] Effect of Laser Auriculotherapy on Quality of Life, Fatigue, and Anxiety in Women with Advanced Breast Cancer: Randomized Clinical Trial
    Marcondes, Larissa
    Ferreira, Poliana Martins
    Sawada, Namie Okino
    Chianca, Tania Couto Machado
    Felix, Jorge Vinicius Cestari
    Guimaraes, Paulo Ricardo Bittencourt
    Kalinke, Luciana Puchalski
    HEALTHCARE, 2025, 13 (02)
  • [23] Detecting outliers beyond tolerance limits derived from statistical process control in patient-specific quality assurance
    Tan, Hong Qi
    Lew, Kah Seng
    Wong, Yun Ming
    Chong, Wen Chuan
    Koh, Calvin Wei Yang
    Chua, Clifford Ghee Ann
    Yeap, Ping Lin
    Ang, Khong Wei
    Lee, James Cheow Lei
    Park, Sung Yong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [24] Effect of online solution-focused counseling on the sexual quality of life of women with a history of breast cancer: a clinical trial
    Bokaie, Mahshid
    Hejazi, Nafiseh Sadat
    Jafari, Mirsaeed
    Shabani, Masoud
    BMC WOMENS HEALTH, 2023, 23 (01)
  • [25] Effect of combined Kinesiotaping and resistive exercise on muscle strength and quality of life in breast cancer survivors: a randomized clinical trial
    Ramadan, Alaa M.
    ElDeeb, Abeer M.
    Ramadan, Ahmed A.
    Aleshmawy, Dina M.
    JOURNAL OF THE EGYPTIAN NATIONAL CANCER INSTITUTE, 2024, 36 (01)
  • [26] Calorie restriction and synbiotics effect on quality of life and edema reduction in breast cancer-related lymphedema, a clinical trial
    Vafa, Saeideh
    Zarrati, Mitra
    Malakootinejad, Marjan
    Totmaj, Ali Saneei
    Zayeri, Farid
    Salehi, Masoud
    Sanati, Vahid
    Haghighat, Shahpar
    BREAST, 2020, 54 : 37 - 45
  • [27] Quality of life in breast cancer patients aged over 70 years, participating in the EORTC 10850 randomised clinical trial
    de Haes, JCJM
    Curran, D
    Aaronson, NK
    Fentiman, IS
    EUROPEAN JOURNAL OF CANCER, 2003, 39 (07) : 945 - 951
  • [28] Effect of online solution-focused counseling on the sexual quality of life of women with a history of breast cancer: a clinical trial
    Mahshid Bokaie
    Nafiseh Sadat Hejazi
    Mirsaeed Jafari
    Masoud Shabani
    BMC Women's Health, 23
  • [29] Effect of combined Kinesiotaping and resistive exercise on muscle strength and quality of life in breast cancer survivors: a randomized clinical trial
    Alaa M. Ramadan
    Abeer M. ElDeeb
    Ahmed A. Ramadan
    Dina M. Aleshmawy
    Journal of the Egyptian National Cancer Institute, 36
  • [30] Statistical process control and verifying positional accuracy of a cobra motion couch using step-wedge quality assurance tool
    Binny, Diana
    Lancaster, Craig M.
    Trapp, Jamie V.
    Crowe, Scott B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 70 - 79