Physiotherapy assessment and treatment of patients with tibial external fixator: a systematic scoping review

被引:1
|
作者
Schell, Mauricio Scholl [1 ,3 ]
de Araujo, Francisco Xavier [2 ]
Silva, Marcelo Faria [1 ]
机构
[1] Univ Fed Ciencias Saude Porto Alegre UFCSPA, Physiotherapy Dept, Post Grad Program Rehabil Sci, Porto Alegre, Brazil
[2] Univ Fed Pelotas UFPel, Physiotherapy Dept, Pelotas, Brazil
[3] Rua Antao Farias,95,apt 701, BR-90035210 Porto Alegre, Rio Grande do S, Brazil
关键词
External fixator; Tibia; rehabilitation; assessment; intervations; scoping review; LOW-BACK-PAIN; BONE DEFECTS; ILIZAROV METHOD; LOWER-LIMB; INTRAMEDULLARY NAIL; PLATEAU FRACTURES; SHAFT FRACTURES; FUNCTIONAL OUTCOMES; SEGMENT TRANSPORT; INFECTED NONUNION;
D O I
10.1080/09638288.2023.2202419
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
PurposeTo map evidence regarding physiotherapy assessment and treatment of patients with tibial external fixator (EF), and to point out literature gaps for further research.MethodsSystematic scoping review conducted in four databases. We included both experimental and non-experimental studies involving patients with tibial EF and outcomes of interest. We recorded study design, population, sample size, sample age, reason for EF use, type of surgery, type of EF used, instruments used for assessing function, pain, quality of life, satisfaction, psychosocial aspects, and physiotherapy treatment descriptions from included studies. We categorised data accordingly to outcomes assessed and physiotherapy treatments description.ResultsEighty-six studies were included involving 3070 patients. Causes of fixator use were traumatic conditions, acquired and congenital deformities, and non-traumatic conditions, like compartmental osteoarthritis. Function was assessed in about three-quarters of included studies, though other outcomes were not presented in most studies. Only one study described satisfactorily the physiotherapy treatment. Almost half of the studies did not provide any description of the rehabilitation process.ConclusionsThere is little evidence about the assessment of function, pain, quality of life, satisfaction, psychosocial aspects, and other outcomes in tibial EF patients. Physiotherapy treatment in these patients is poorly reported.Protocol registration: Open Science Framework: doi:10.17605/OSF.IO/UT2DA
引用
收藏
页码:1673 / 1684
页数:12
相关论文
共 50 条
  • [1] The treatment of infected tibial nonunion by bone transport using the Ilizarov external fixator and a systematic review of infected tibial nonunion treated by Ilizarov methods
    Yin, Peng
    Zhang, Qun
    Mao, Zhi
    Li, Tongtong
    Zhang, Lihai
    Tang, Peifu
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (03): : 426 - 435
  • [2] Physiotherapy Intervention Focusing on Proprioceptive Retraining for Tibial Pseudoarthrosis Patients Operated With Ilizarov External Fixator: A Case Report
    Rohankar, Anushka
    Thakre, Vaishnavi M.
    Deshpande, Maithili M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [3] Locked plating as an external fixator in treating tibial fractures A PRISMA-compliant systematic review
    Luo, Peng
    Xu, Ding
    Wu, Jia
    Chen, Yi-Heng
    MEDICINE, 2017, 96 (49)
  • [4] Treatment of 103 displaced tibial diaphyseal fractures with a radiolucent unilateral external fixator
    Dall'Oca, C.
    Christodoulidis, A.
    Bortolazzi, R.
    Bartolozzi, P.
    Lavini, F.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (11) : 1377 - 1382
  • [5] Treatment of type IIIA open fractures of tibial shaft with Ilizarov external fixator versus unreamed tibial nailing
    Inan, Muharrem
    Halici, Mehmet
    Ayan, Irfan
    Tuncel, Mehmet
    Karaoglu, Sinan
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (08) : 617 - 623
  • [6] Treatment of type IIIA open fractures of tibial shaft with Ilizarov external fixator versus unreamed tibial nailing
    Muharrem Inan
    Mehmet Halici
    Irfan Ayan
    Mehmet Tuncel
    Sinan Karaoglu
    Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 617 - 623
  • [7] The Ilizarov external fixator - a useful alternative for the treatment of proximal tibial fractures A prospective observational study of 30 consecutive patients
    Ramos, Telmo
    Ekholm, Carl
    Eriksson, Bengt I.
    Karlsson, Jon
    Nistor, Lars
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [8] Treatment of comminuted tibial shaft fractures in four dogs with the use of interlocking nail connected with type I external fixator
    Piorek, A.
    Adamiak, Z.
    Jaskolska, M.
    Zhalniarovich, Y.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2012, 15 (04): : 661 - 666
  • [9] Treatment of distal tibial fractures with the Ilizarov external fixator - a prospective observational study in 39 consecutive patients
    Ramos, Telmo
    Karlsson, Jon
    Eriksson, Bengt I.
    Nistor, Lars
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [10] Treatment of distal tibial fractures with the Ilizarov external fixator - a prospective observational study in 39 consecutive patients
    Telmo Ramos
    Jón Karlsson
    Bengt I Eriksson
    Lars Nistor
    BMC Musculoskeletal Disorders, 14