Adaptive IoU Thresholding for Improving Small Object Detection: A Proof-of-Concept Study of Hand Erosions Classification of Patients with Rheumatic Arthritis on X-ray Images

被引:12
作者
Radke, Karl Ludger [1 ]
Kors, Matthias [1 ]
Mueller-Lutz, Anja [1 ]
Frenken, Miriam [1 ]
Wilms, Lena Marie [1 ]
Baraliakos, Xenofon [2 ]
Wittsack, Hans-Joerg [1 ]
Distler, Joerg H. W. [3 ,4 ]
Abrar, Daniel B. [1 ]
Antoch, Gerald [1 ]
Sewerin, Philipp [2 ,3 ,4 ]
机构
[1] Univ Dusseldorf, Med Fac, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
[2] Ruhr Univ Bochum, Rheumazentrum Ruhrgebiet, D-44649 Herne, Germany
[3] Univ Hosp Dusseldorf, Dept Rheumatol, D-40225 Dusseldorf, Germany
[4] Univ Hosp Dusseldorf, Hiller Res Unit, D-40225 Dusseldorf, Germany
关键词
X-ray; imaging; deep learning; AI; RetinaNet; rheumatic arthritis; innovative techniques; SHARP/VAN;
D O I
10.3390/diagnostics13010104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In recent years, much research evaluating the radiographic destruction of finger joints in patients with rheumatoid arthritis (RA) using deep learning models was conducted. Unfortunately, most previous models were not clinically applicable due to the small object regions as well as the close spatial relationship. In recent years, a new network structure called RetinaNets, in combination with the focal loss function, proved reliable for detecting even small objects. Therefore, the study aimed to increase the recognition performance to a clinically valuable level by proposing an innovative approach with adaptive changes in intersection over union (IoU) values during training of Retina Networks using the focal loss error function. To this end, the erosion score was determined using the Sharp van der Heijde (SvH) metric on 300 conventional radiographs from 119 patients with RA. Subsequently, a standard RetinaNet with different IoU values as well as adaptively modified IoU values were trained and compared in terms of accuracy, mean average accuracy (mAP), and IoU. With the proposed approach of adaptive IoU values during training, erosion detection accuracy could be improved to 94% and an mAP of 0.81 +/- 0.18. In contrast Retina networks with static IoU values achieved only an accuracy of 80% and an mAP of 0.43 +/- 0.24. Thus, adaptive adjustment of IoU values during training is a simple and effective method to increase the recognition accuracy of small objects such as finger and wrist joints.
引用
收藏
页数:14
相关论文
共 40 条
[1]   Cartilage Degradation in Psoriatic Arthritis Is Associated With Increased Synovial Perfusion as Detected by Magnetic Resonance Imaging [J].
Abrar, Daniel B. ;
Schleich, Christoph ;
Mueller-Lutz, Anja ;
Frenken, Miriam ;
Radke, K. Ludger ;
Vordenbaeumen, Stefan ;
Schneider, Matthias ;
Ostendorf, Benedikt ;
Sewerin, Philipp .
FRONTIERS IN MEDICINE, 2020, 7
[2]   Detection of early cartilage degeneration in the tibiotalar joint using 3 T gagCEST imaging: a feasibility study [J].
Abrar, Daniel B. ;
Schleich, Christoph ;
Radke, Karl Ludger ;
Frenken, Miriam ;
Stabinska, Julia ;
Ljimani, Alexandra ;
Wittsack, Hans-Joerg ;
Antoch, Gerald ;
Bittersohl, Bernd ;
Hesper, Tobias ;
Nebelung, Sven ;
Mueller-Lutz, Anja .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (02) :249-260
[3]   When to use the Bonferroni correction [J].
Armstrong, Richard A. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (05) :502-508
[4]   Improved diagnosis of rheumatoid arthritis using an artificial neural network [J].
Bai, Linlu ;
Zhang, Yuan ;
Wang, Pan ;
Zhu, Xiaojun ;
Xiong, Jing-Wei ;
Cui, Liyan .
SCIENTIFIC REPORTS, 2022, 12 (01)
[5]   SSD-EMB: An Improved SSD Using Enhanced Feature Map Block for Object Detection [J].
Choi, Hong-Tae ;
Lee, Ho-Jun ;
Kang, Hoon ;
Yu, Sungwook ;
Park, Ho-Hyun .
SENSORS, 2021, 21 (08)
[6]  
Cohen J., 1988, STAT POWER ANAL BEHA
[7]  
Del Prete R., 2021, P 2021 IEEE 6 INT FO, P171
[8]   Automatic Detection and Counting of Blood Cells in Smear Images Using RetinaNet [J].
Dralus, Grzegorz ;
Mazur, Damian ;
Czmil, Anna .
ENTROPY, 2021, 23 (11)
[9]   To Contrast or Not to Contrast? On the Role of Contrast Enhancement in Hand MRI Studies of Patients with Rheumatoid Arthritis [J].
Frenken, Miriam ;
Ruebsam, Gesa ;
Mewes, Alexander ;
Radke, Karl Ludger ;
Li, Lien ;
Wilms, Lena M. ;
Nebelung, Sven ;
Abrar, Daniel B. ;
Sewerin, Philipp .
DIAGNOSTICS, 2022, 12 (02)
[10]   A computer-aided diagnosis system for the classification of COVID-19 and non-COVID-19 pneumonia on chest X-ray images by integrating CNN with sparse autoencoder and feed forward neural network [J].
Gayathri, J. L. ;
Abraham, Bejoy ;
Sujarani, M. S. ;
Nair, Madhu S. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 141