Anatase titanium oxide nanoparticles and multi-walled carbon nanotubes-modified carbon paste electrode for simultaneous determination of avanafil and doxorubicin in plasma samples

被引:18
|
作者
Ali, Al-Montaser Bellah H. [1 ]
Rageh, Azza H. [1 ]
Abdel-aal, Fatma A. M. [1 ]
Mohamed, Abdel-Maaboud I. [1 ]
机构
[1] Assiut Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Assiut 71526, Egypt
关键词
AnataseTiO2; nanoparticles; Avanafil; Doxorubicin; Multi-walled carbon nanotubes; Pharmacokinetic interaction study; Square-wave adsorptive anodic stripping; voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; 5; INHIBITOR; SILDENAFIL; STABILITY; SENSOR; ACID; HYDROCHLORIDE; VOLTAMMETRY; METABOLITES; CANCER;
D O I
10.1016/j.microc.2022.108261
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Patients who receive anticancer drugs, might experience loss of sexual desire together with erectile dysfunction as one of cancer medications' adverse effects. This might have a negative effect on their psychological functioning and quality of life and accordingly phosphodiesterase type 5 (PDE5) inhibitors as sex stimulants are used. One of the recently FDA-approved members of this class of drugs is avanafil (AVN) that is administered to assist in improving penile erection. Because of the seriousness of the cancer patient's health condition, it is mandatory to recognize the possible pharmacokinetic interactions in case of administering other drugs at the same time. Therefore, a sensitive sensor derived from carbon paste electrode (CPE) modified with anatase titanium dioxide nanoparticles (TiO2-NPs) and multi-walled carbon nanotubes (MWCNTs) was designed for the simultaneous determination of AVN and the anticancer drug doxorubicin (DOX) in spiked and real rabbit plasma samples. Xray powder diffraction (XRD), Fourier transform infrared (FT-IR), and scanning electron microscopy (SEM) were employed to fully characterize the fabricated electrode. The modified electrode offers a considerable improvement in voltammetric sensitivity toward oxidation of AVN and DOX, compared to the bare electrode. A good separation was achieved between the oxidation peak potentials of AVN (1.4 V) and DOX (0.8 V). The effect of different voltammetric parameters on the peak separation and sensitivity for both drugs was studied to select the optimum experimental conditions. It was found that the optimum pH for the simultaneous determination of both drugs was obtained utilizing a Britton-Robinson buffer (BR) of pH 3.0. Furthermore, the electrochemical oxidation of AVN and DOX was evaluated with different modified carbon paste electrodes using cyclic voltammetry (CV) and square-wave adsorptive anodic stripping voltammetry (SWAdASV). The analytical curves for the quantitative simultaneous determination of AVN and DOX exhibited acceptable linearity within the concentration range from (0.10-6.0 mu mol L-1 for AVN) and (5.0-35.0 mu mol L-1 for DOX) in spiked rabbit plasma. Detection and quantitation limits were determined to be 0.035 and 0.10 mu mol L-1 in the case of AVN and 1.3 and 4.0 mu mol L-1 in the case of DOX, respectively. The method was effectively applied for the analysis of AVN in real rabbit plasma samples after the coadministration of DOX. Moreover, the proposed voltammetric method was useful as a therapeutic drug monitoring method to investigate the possible pharmacokinetic interactions between AVN and DOX in real rabbit plasma. An increase in the level of AVN in rabbit plasma was observed after administering DOX, and accordingly, the dose of AVN should be adjusted and monitored.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] A Sensitive Simultaneous Determination of Acetaminophen and Indomethacin at Multi-walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Babaei, Ali
    Farshbaf, Mojtaba
    Afrasiabi, Mohammad
    Dehdashti, Aliyeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (06): : 564 - 578
  • [12] Determination of Mn(II) ion by a modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) in different water samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 699 - 707
  • [13] A Sensor for Simultaneous Determination of Acetaminophen and Codeine at Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes
    Babaei, Ali
    Dehdashti, Aliyeh
    Afrasiabi, Mohammad
    Babazadeh, Mitra
    Farshbaf, Mojtaba
    Bamdad, Farzad
    SENSOR LETTERS, 2012, 10 (3-4) : 1039 - 1046
  • [14] Thiol functionalized carbon ceramic electrode modified with multi-walled carbon nanotubes and gold nanoparticles for simultaneous determination of purine derivatives
    Ferrag, Celia
    Noroozifar, Meissam
    Kerman, Kagan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [15] Sensitive Determination of Rhodamine B in Real Samples at the Surface of a Multi-walled Carbon Nanotubes Paste Electrode
    Golestaneh, Mahshid
    Ghoreishi, Sayed Mehdi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (01): : 81 - 92
  • [16] A Sensor for Determination of Tramadol in Pharmaceutical Preparations and Biological Fluids Based on Multi-Walled Carbon Nanotubes-Modified Glassy Carbon Electrode
    Afrasiabi, Mohammad
    Zad, Zeinab Rezayati
    Kianipour, Shokat
    Babaei, Ali
    Taheri, Ali Reza
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (04): : 1106 - 1112
  • [17] Potentiometric Determination of Salbutamol using Carbon Paste Electrode Assisted with Multi-Walled Carbon Nanotubes
    Tamaddon, Atefeh
    Asghari, Arezoo
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (02): : 230 - 238
  • [18] Surface decoration of multi-walled carbon nanotubes modified carbon paste electrode with CuO nanoparticles for electrocatalytic oxidation of nitrite
    Xia, Qiang
    Zhang, ShuPing
    Qu, Song
    Zhu, YuanZheng
    Ma, Jie
    Zhang, Zhen
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2020, 59 (05): : 625 - 632
  • [19] Fabrication of a modified electrode based on multi-walled carbon nanotubes decorated with iron oxide nanoparticles for the determination of enrofloxacin
    Khaloo, Shokooh Sadat
    Mozaffari, Shahla
    Barekat, Afsane
    Karimi, Fereshte
    Micro & Nano Letters, 2015, 10 (10): : 561 - 566
  • [20] Multi-walled Carbon Nanotubes/Graphite Nanosheets Modified Glassy Carbon Electrode for the Simultaneous Determination of Acetaminophen and Dopamine
    Zhang, Susu
    He, Ping
    Zhang, Guangli
    Lei, Wen
    He, Huichao
    ANALYTICAL SCIENCES, 2015, 31 (07) : 657 - 662