Effects of storage temperature and time on metabolite profiles measured in dried blood spots, dried blood microsamplers, and plasma

被引:3
|
作者
Petrick, Lauren M. [1 ,2 ,3 ]
Niedzwiecki, Megan M. [1 ,2 ]
Dolios, Georgia [1 ]
Guan, Haibin [1 ]
Tu, Peijun [1 ]
Wright, Robert O. [1 ,2 ]
Wright, Rosalind J. [1 ,2 ,4 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Environm Med & Publ Hlth, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Inst Expos Res, New York, NY USA
[3] Sheba Med Ctr, Bert Strassburger Metab Ctr, Tel Hashomer, Israel
[4] Icahn Sch Med Mt Sinai, Dept Pediat, New York, NY USA
基金
美国国家卫生研究院;
关键词
Dried blood spots; Microsamplers; Storage conditions; Temperature; Metabolomics; Exposome; FILTER-PAPER; STABILITY; METABOLOMICS; SAMPLES; SERUM;
D O I
10.1016/j.scitotenv.2023.169383
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The practical advantages of capillary whole blood collection over venipuncture plasma collection for human exposome research are well known. However, before epidemiologists, clinicians, and public health researchers employ these microvolume sample collections, a rigorous evaluation of pre-analytical storage conditions is needed to develop protocols that maximize sample stability and reliability over time. Therefore, we performed a controlled experiment of dried whole blood collected on 10 mu L Mitra microsamplers (DBM), 5-mm punches of whole blood from a dried blood spot (DBS), and 10 mu L of plasma, and evaluated the effects of storage conditions at 4 degrees C,-20 degrees C, or-80 degrees C for up to 6 months on the resulting metabolite profiles measured with untargeted liquid chromatography-high resolution mass spectrometry (LC-HRMS). At-80 degrees C storage conditions, metabolite profiles from DBS, DBM, and plasma showed similar stability. While DBS and DBM metabolite profiles remained similarly stable at-20 degrees C storage, plasma profiles showed decreased stability at-20 degrees C compared to-80 degrees C storage. At refrigerated temperatures (4 degrees C), metabolite profiles collected on DBM were more stable than plasma or DBS, particularly for lipid classes. These results inform robust capillary blood sample storage protocols for DBM and DBS at potentially warmer temperatures than-80 degrees C, which may facilitate blood collections for populations outside of a clinical setting.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of maternal venous blood metabolomics collected as dried blood spots, dried blood microsamplers, and plasma for integrative environmental health research
    Petrick, Lauren
    Guan, Haibin
    Page, Grier P.
    Dolios, Georgia
    Niedzwiecki, Megan M.
    Wright, Robert O.
    Wright, Rosalind J.
    ENVIRONMENT INTERNATIONAL, 2024, 187
  • [2] Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assay
    Andreotti, Mauro
    Pirillo, Maria
    Guidotti, Giovanni
    Ceffa, Susanna
    Paturzo, Giovanna
    Germano, Paola
    Luhanga, Richard
    Chimwaza, David
    Mancini, Maria Grazia
    Marazzi, Maria Cristina
    Vella, Stefano
    Palombi, Leonardo
    Giuliano, Marina
    JOURNAL OF CLINICAL VIROLOGY, 2010, 47 (01) : 4 - 7
  • [3] Validation of dried blood spots in monitoring toxoplasmosis
    Hegazy, Mamdouh M.
    Hegazy, Mona K.
    Azab, Manar S.
    Nabih, Nairmen
    PATHOGENS AND GLOBAL HEALTH, 2020, 114 (05) : 242 - 250
  • [4] Measurement of troponin-T in dried blood spots and dried plasma spots: A pilot study
    Almagor, Yotam
    Eventov-Friedman, Smadar
    Nir, Amiram
    Sror, Awad
    Saada, Ann
    JOURNAL OF PEDIATRIC BIOCHEMISTRY, 2014, 4 (03) : 153 - 157
  • [5] Stability of ceftolozane in human plasma and dried blood spots: Implications for transport and storage
    Martens-Lobenhoffer, Jens
    Hinderhofer, Matthias
    Troeger, Uwe
    Bode-Boeger, Stefanie M.
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2020, 103
  • [6] Comparative study on anti-HCV testing using plasma, dried plasma spots (DPS), and dried blood spots (DBS)
    Ma, Jieqiong
    He, Lin
    Chen, Kai
    Wang, Yuehua
    Ren, Yanan
    Xing, Wenge
    Jiang, Yan
    BIOSAFETY AND HEALTH, 2021, 3 (01) : 50 - 55
  • [7] Estimating blood volume on dried blood spots
    Seo, Sung -Hee
    Batterman, Stuart
    FORENSIC CHEMISTRY, 2024, 37
  • [8] Effect of specimen storage conditions on newborn dried blood spots used to assess Toxoplasma gondii immunoglobulin M (IgM)
    Mei, Joanne V.
    Li, LiXia
    Rasmussen, Sonja A.
    Collier, Sarah
    Frias, Jaime L.
    Honein, Margaret A.
    Shaw, Gary M.
    Lorey, Fred
    Meyer, Robert
    Chaing, Shu
    Canfield, Mark A.
    Jones, Jeffrey
    Hannon, W. Harry
    CLINICA CHIMICA ACTA, 2011, 412 (5-6) : 455 - 459
  • [9] Dried blood spots: An evaluation of utility in the field
    Su, Xu
    Carlson, Bradley F.
    Wang, Xiexiu
    Li, Xiaoyan
    Zhang, Ying
    Montgomery, JoLynn P.
    Ding, Yaxing
    Wagner, Abram L.
    Gillespie, Brenda
    Boulton, Matthew L.
    JOURNAL OF INFECTION AND PUBLIC HEALTH, 2018, 11 (03) : 373 - 376
  • [10] The effects of iron injection on blood doping biomarkers in dried blood spots
    Loria, Francesco
    Maret, Estelle
    Schobinger, Celine
    Kuuranne, Tiia
    Grabherr, Silke
    Leuenberger, Nicolas
    DRUG TESTING AND ANALYSIS, 2023, 15 (04) : 444 - 448